用3 w-Spectlein方法高灵敏地测量悬浮膜(SiN和金刚石)的热导率

Highly sensitive thermal conductivity measurements of suspended membranes (SiN and diamond) using a 3w-Volklein method

A. Sikora, H. Ftouni, J. Richard, C. Hébert, D. Eon, F. Omnès, O. Bourgeois

摘要:

介绍了一种用于测量膜热物性的悬挂式系统。灵敏的热测量是基于耦合到V $\ddot{o}$ lklein几何的3 $ω$动态方法。使用微加工工艺获得的装置允许测量膜的面内热导率,其灵敏度小于10 nW/K(室温下+/- $5x10^{-3}$ Wm $^{-1}K^{-1}$)和非常高的分辨率($ΔK/K =10^{-3}$)。位于膜中心的传感器(加热器/温度计)用于产生热通量的振荡,并使用惠斯通电桥装置测量三次谐波下的温度振荡。在室温下测得的功率低至0.1nanoWatt。该方法已用于测量厚度为100 ~ 400 nm的低应力氮化硅薄膜和多晶金刚石薄膜的热性能。在多晶金刚石膜上测量的热导率支持对热传输的显著晶粒尺寸效应。

英文摘要:

A suspended system for measuring the thermal properties of membranes is presented. The sensitive thermal measurement is based on the 3$ω$ dynamic method coupled to a V$\ddot{o}$lklein geometry. The device obtained using micro-machining processes allows the measurement of the in-plane thermal conductivity of a membrane with a sensitivity of less than 10nW/K (+/-$5x10^{-3}$Wm$^{-1}K^{-1}$ at room temperature) and a very high resolution ($ΔK/K =10^{-3}$). A transducer (heater/thermometer) centered on the membrane is used to create an oscillation of the heat flux and to measure the temperature oscillation at the third harmonic using a Wheatstone bridge set-up. Power as low as 0.1nanoWatt has been measured at room temperature. The method has been applied to measure thermal properties of low stress silicon nitride and polycrystalline diamond membranes with thickness ranging from 100 nm to 400 nm. The thermal conductivity measured on the polycrystalline diamond membrane support a significant grain size effect on the thermal transport.