arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2206.15468astro-ph.IM
收藏

BEaTriX首次亮相,这是ATHENA任务中模块化X射线光学器件的新测试设施

First light of BEaTriX, the new testing facility for the modular X-ray optics of the ATHENA mission

S. Basso, B. Salmaso, D. Spiga, M. Ghigo, G. Vecchi, G. Sironi, V. Cotroneo, P. Conconi, E. Redaelli, A. Bianco, G. Pareschi, G. Tagliaferri, D. Sisana, C. Pell… 展开作者

S. Basso, B. Salmaso, D. Spiga, M. Ghigo, G. Vecchi, G. Sironi, V. Cotroneo, P. Conconi, E. Redaelli, A. Bianco, G. Pareschi, G. Tagliaferri, D. Sisana, C. Pelliciari, M. Fiorini, S. Incorvaia, M. Uslenghi, L. Paoletti, C. Ferrari, R. Lolli, A. Zappettini, M. Sanchez del Rio, G. Parodi, V. Burwitz, S. Rukdee, G. Hartner, T. Müller, T. Schmidt, A. Langmeier, D. Della Monica Ferreira, S. Massahi, N. C. Gellert, F. Christensen, M. Bavdaz, I. Ferreira, M. Collon, G. Vacanti, N. M. Barrière

摘要:

射束扩展器测试X射线设施(BEaTriX)是一种独特的X射线设备,目前在意大利Merate的国家天体物理研究所(INAF)、Osservatorio Astronomico di Brera(OAB)运行。它是专门设计用于测量高能天体物理学高级望远镜(ATHENA)的X射线镜模块(X-ray)的点扩散函数(PSF)和有效面积(EA)的,基于硅孔光学(SPO)技术,在集成到镜组件之前进行验证。为此,BEaTriX产生4.51 keV的宽、均匀、单色和准直X射线束。[...]在BEaTriX中,具有钛阳极的微焦点X射线源被放置在抛物面镜的焦点中,抛物面镜产生平行光束。晶体单色器选择4.51 keV线,其通过相对于晶面不对称切割的晶体扩展到最终尺寸。[...]表征后,BEaTriX光束的标称尺寸为170 mm x 60 mm,垂直发散度为1.65 arcsec,水平发散度在2.7和3.45 arcsec之间变化,具体取决于单色仪设置:高准直或高强度。从一种配置到另一种配置,每单位面积的通量从10到50光子/s/cm 2变化。使用SPO MM测试BEaTriX光束性能,SPO MM的入射光瞳被扩展光束完全照亮,并且其焦点直接成像到相机上。第一次光测试返回的PSF和EA与预期完全一致。截至目前,BEaTriX的4.51 keV光束线已投入使用,可以表征模块化X射线光学器件,测量其PSF和EA,典型曝光时间为30分钟。[...]我们期望BEaTriX成为模块化X射线光学器件功能测试的关键设备,例如ATHENA的SPO光学器件。

英文摘要:

The Beam Expander Testing X-ray facility (BEaTriX) is a unique X-ray apparatus now operated at the Istituto Nazionale di Astrofisica (INAF), Osservatorio Astronomico di Brera (OAB), in Merate, Italy. It has been specifically designed to measure the point spread function (PSF) and the effective area (EA) of the X-ray mirror modules (MMs) of the Advanced Telescope for High-ENergy Astrophysics (ATHENA), based on silicon pore optics (SPO) technology, for verification before integration into the mirror assembly. To this end, BEaTriX generates a broad, uniform, monochromatic, and collimated X-ray beam at 4.51 keV. [...] In BEaTriX, a micro-focus X-ray source with a titanium anode is placed in the focus of a paraboloidal mirror, which generates a parallel beam. A crystal monochromator selects the 4.51 keV line, which is expanded to the final size by a crystal asymmetrically cut with respect to the crystalline planes. [...] After characterization, the BEaTriX beam has the nominal dimensions of 170 mm x 60 mm, with a vertical divergence of 1.65 arcsec and a horizontal divergence varying between 2.7 and 3.45 arcsec, depending on the monochromator setting: either high collimation or high intensity. The flux per area unit varies from 10 to 50 photons/s/cm2 from one configuration to the other. The BEaTriX beam performance was tested using an SPO MM, whose entrance pupil was fully illuminated by the expanded beam, and its focus was directly imaged onto the camera. The first light test returned a PSF and an EA in full agreement with expectations. As of today, the 4.51 keV beamline of BEaTriX is operational and can characterize modular X-ray optics, measuring their PSF and EA with a typical exposure of 30 minutes. [...] We expect BEaTriX to be a crucial facility for the functional test of modular X-ray optics, such as the SPO MMs for ATHENA.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑