摘要:

Arcus是一种提出的软X射线光栅光谱仪探测器。它的目的是通过绘制星系和星系团内部和之间的热气体以及描述来自超大质量黑洞的喷流和风来探索宇宙反馈,并研究原行星盘和恒星吸积的动力学。Arcus的特点是为雅典娜任务开发的12米焦距掠入射硅孔光学器件。临界角透射(CAT)光栅有效地将高衍射级分散到CCD上。我们报告了类似Arcus的CAT光栅的新的和改进的X射线性能结果,包括记录两个共对准CAT光栅的分辨率。多个Arcus原型光栅面在PANTER设施中由SPO照明。刻面由结合到金属框架的$32\times32.5$ mm $^2$图案化硅膜组成。根据测量的膜中的光栅条的平均倾斜角来调整结合角。两个同时照射的小面显示出18 $^{\rm th}$和21 $^{\rm st}$级的Al-K $_α$双峰的轻微增宽,最佳拟合记录有效分辨能力为$R_G \approx 1.3^{+\infty}_{-0.5}\times10^4$($3σ$),约为Arcus要求的3 - 4倍。我们测量了准全照明光栅的衍射效率在O-K波长在4 - 7级的Arcus类配置和比较结果与同步辐射光斑测量。几何效应和韧致辐射连续校正后,我们发现在两个不同的设施,以及与用于Arcus有效面积预测的模型之间的充分和现场照明协议。我们发现,这些飞行状光栅满足衍射效率,大大超过了分辨率Arcus的要求。

英文摘要:

Arcus is a proposed soft x-ray grating spectrometer Explorer. It aims to explore cosmic feedback by mapping hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes, and to investigate the dynamics of protoplanetary discs and stellar accretion. Arcus features 12 m-focal-length grazing-incidence silicon pore optics (SPO) developed for the Athena mission. Critical-angle transmission (CAT) gratings efficiently disperse high diffraction orders onto CCDs. We report new and improved x-ray performance results for Arcus-like CAT gratings, including record resolving power for two co-aligned CAT gratings. Multiple Arcus prototype grating facets were illuminated by an SPO at the PANTER facility. The facets consist of $32\times32.5$ mm$^2$ patterned silicon membranes, bonded to metal frames. The bonding angle is adjusted according to the measured average tilt angle of the grating bars in the membrane. Two simultaneously illuminated facets show minor broadening of the Al-K$_α$ doublet in 18$^{\rm th}$ and 21$^{\rm st}$ orders with a best fit record effective resolving power of $R_G \approx 1.3^{+\infty}_{-0.5}\times10^4$ ($3σ$), about 3-4 times the Arcus requirement. We measured the diffraction efficiency of quasi-fully illuminated gratings at O-K wavelengths in orders 4-7 in an Arcus-like configuration and compare results with synchrotron spot measurements. After corrections for geometrical effects and bremsstrahlung continuum we find agreement between full and spot illumination at the two different facilities, as well as with the models used for Arcus effective area predictions. We find that these flight-like gratings meet diffraction efficiency and greatly exceed resolving power Arcus requirements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑