arXiv 2204.00475astro-ph.IMastro-ph.HE
收藏

用于低功率CubeSat应用的CdZnTe检测器的表征

Characterization of a CdZnTe detector for a low-power CubeSat application

Giulio Lucchetta, Markus Ackermann, David Berge, Ingo Bloch, Rolf Bühler, Hermann Kolanoski, Wolfgang Lange, Francesco Zappon

摘要:

我们报告了为\emph{MeVCube}项目定制设计的像素化CdZnTe探测器的光谱和成像性能:CubeSat平台上的小型康普顿望远镜。\emph{MeVCube}预计将覆盖$200\;\mathrm{keV}$和$4\;\mathrm{MeV}$之间的能量范围,性能可与上一代更大的卫星相媲美。为了实现这一目标,需要单个探测器的半高宽(FWHM)能量分辨率为百分之几,$3$ -D空间分辨率为几毫米。小型卫星中存在的严重的功率限制要求探测器使用非常低功率的读出电子设备。该读出电路基于\emph{Ideas}公司开发的VATA 450. 3专用集成电路,功耗仅为$0.25\;\mathrm{mW/channel}$,在动态范围、噪声和线性度方面表现出良好的性能。一个$2.0\;\mathrm{cm} \times 2.0\;\mathrm{cm} \times 1.5\;\mathrm{cm}$ CdZnTe探测器,与一个定制的$8 \times 8$像素阳极结构读出的VATA 450.3 ASIC,已被测试。基于分立式\emph{Amptek} A250 F电荷灵敏前置放大器和DRS 4 ASIC,实现了阴极的初步读出系统。在$662\;\mathrm{keV}$的伽马能量下测量了$3\%$ FWHM附近的能量分辨率;在$200\;\mathrm{keV}$下,平均能量分辨率为$6.5\%$,在高于$1\;\mathrm{MeV}$的能量下降低至$\lesssim 2\%$。达到了$\approx 2\,\mathrm{mm}$的$3$ -D空间分辨率。

英文摘要:

We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the \emph{MeVCube} project: a small Compton telescope on a CubeSat platform. \emph{MeVCube} is expected to cover the energy range between $200\;\mathrm{keV}$ and $4\;\mathrm{MeV}$, with performance comparable to the last generation of larger satellites. In order to achieve this goal, an energy resolution of few percent in full width at half maximum (FWHM) and a $3$-D spatial resolution of few millimeters for the individual detectors are needed. The severe power constraints present in small satellites require very low power read-out electronics for the detector. Our read-out is based on the VATA450.3 ASIC developed by \emph{Ideas}, with a power consumption of only $0.25\;\mathrm{mW/channel}$, which exhibits good performance in terms of dynamic range, noise and linearity. A $2.0\;\mathrm{cm} \times 2.0\;\mathrm{cm} \times 1.5\;\mathrm{cm}$ CdZnTe detector, with a custom $8 \times 8$ pixel anode structure read-out by a VATA450.3 ASIC, has been tested. A preliminary read-out system for the cathode, based on a discrete \emph{Amptek} A250F charge sensitive pre-amplifier and a DRS4 ASIC, has been implemented. An energy resolution around $3\%$ FWHM has been measured at a gamma energy of $662\;\mathrm{keV}$; at $200\;\mathrm{keV}$ the average energy resolution is $6.5\%$, decreasing to $\lesssim 2\%$ at energies above $1\;\mathrm{MeV}$. A $3$-D spatial resolution of $\approx 2\,\mathrm{mm}$ is achieved.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑