arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2303.10075astro-ph.IMastro-ph.HEhep-ex
收藏

由于CdZnTe(CZT)探测器中的像素失真引起的成像效应--来自HREXI校准设施(HCF)的结果

Imaging effects due to pixel distortions in CdZnTe (CZT) detectors -- results from the HREXI Calibration Facility (HCF)

Arkadip Basak, Branden Allen, Jaesub Hong, Daniel P. Violette, Jonathan Grindlay

摘要:

ProtoEXIST 2(P2)是一个原型成像X射线探测器平面,用于5 - 200 keV能量带的宽场时域天体物理学(TDA)。它由8个$\times$ 8阵列组成,这些阵列由5 mm厚、2 cm $\times$ 2 cm像素化(32 $\times$ 32)CdZnTe(CZT)探测器组成,间距为0.6 mm,利用NuSTAR ASIC(NuASIC)进行读出。在最初的探测器研制过程中,直到对整个探测器平面进行飞行后检查,在很大一部分探测器中观察到预期像素位置和形状的变形。HREXI(高分辨率高能X射线成像仪)校准设备(HCF)的设计和委托,以改善这些早期的实验,并迅速映射和表征像素的不均匀性和CZT探测器平面内的缺陷,分辨率低至50 $\rm μ$ m。使用该设备,在100 $\rm μ$ m分辨率下测量P2的亚像素级探测器响应,并进行分析,以提取和评估各个像素的面积和轮廓、它们在整个P2探测器平面上的形态,以与先前的测量结果进行比较,并提供额外的表征。在这篇文章中,我们评估的编码孔径望远镜的成像性能使用观察到的像素形态P2探测器。这项调查将作为HREXI探测器平面开发中探测器选择的初步指南,用于未来实施旨在提供全天空同步和连续成像的4pi X射线成像天文台(4piXIO)任务($\rm 4π$ sr),具有$\rm \simeq$ 2角分角分辨率和$\simeq$ 10角秒源定位,以及其它,未来的编码孔径仪器

英文摘要:

ProtoEXIST2 (P2) was a prototype imaging X-ray detector plane developed for wide-field Time Domain Astrophysics (TDA) in the 5 - 200 keV energy band. It was composed of an 8 $\times$ 8 array of 5 mm thick, 2cm $\times$ 2cm pixelated (32 $\times$ 32) CdZnTe (CZT) detectors with a 0.6 mm pitch that utilize the NuSTAR ASIC(NuASIC) for readout. During the initial detector development process leading up to post-flight examination of the entire detector plane, distortions in expected pixel positions and shapes were observed in a significant fraction of the detectors. The HREXI (High Resolution Energetic X-ray Imager) Calibration Facility (HCF) was designed and commissioned to improve upon these early experiments and to rapidly map out and characterize pixel non-uniformities and defects within CZT detector planes at resolutions down to 50 $\rm μ$m. Using this facility, the sub-pixel level detector response of P2 was measured at 100 $\rm μ$m resolution and analyzed to extract and evaluate the area and profile of individual pixels, their morphology across the entire P2 detector plane for comparison with previous measurements and to provide additional characterization. In this article, we evaluate the imaging performance of a coded-aperture telescope using the observed pixel morphology for P2 detectors. This investigation will serve as an initial guide for detector selection in the development of HREXI detector planes, for the future implementation of the 4pi X-Ray Imaging Observatory (4piXIO) mission which aims to provide simultaneous and continuous imaging of the full sky ($\rm 4π$ sr) in the 3-200 keV energy band with $\rm \simeq$ 2 arcmin angular resolution and $\simeq$ 10 arcsec source localization, as well as other, future coded-aperture instruments.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑