arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2203.02332physics.ins-detastro-ph.IMhep-exnucl-exphysics.space-ph
收藏

5 mm厚正交条CdZnTe探测器系统电极设计的优化研究

Optimization study of the electrode design of a 5 mm thick orthogonal-strip CdZnTe detector system

Ali Murteza Altingun, Emrah Kalemci

摘要:

电极的几何形状是决定正交条探测器性能的最重要因素之一。本工作的目的是研究一个5 mm厚的交叉条CdZnTe探测器的性能与不同的电极宽度。我们的研究包括两个主要部分,模拟和实验。我们使用了四种不同的阳极尺寸,范围从0.1 mm到0.6 mm。阳极与尺寸从0.3 mm到0.85 mm不等的转向电极穿插。阳极和转向电极条之间的最大间隙尺寸设置为0.3 mm,而最小间隙尺寸为0.125 mm。根据转向电极偏置电压,能量分辨率,和电荷共享效应。对于模拟,我们开发了一个基于C++的模拟程序内的CdZnTe探测器和电极处的电荷收集的电荷传输。对于光子相互作用,我们使用GEANT 4工具包,对于电场和加权电位模拟,我们使用COMSOL软件。结果表明,当-500 V施加到阴极时,-50 V是我们的检测器的最佳转向电极偏压,并且能量分辨率性能随着转向电极宽度的增加而下降。此外,电荷共享效应对于较大的转向电极尺寸变得更占主导地位。并将实验结果与仿真结果进行了比较。仿真结果与实验结果吻合较好,验证了仿真模型的正确性.尽管如此,我们的模拟框架需要更好地估计CdZnTe的固有噪声。这些结果表明,电极宽度和转向电极偏置之间的优化研究是必要的,以获得最佳性能的正交条CdZnTe探测器。

英文摘要:

The geometry of electrodes is one of the most important factors in determining the performance of orthogonal-strip detectors. The aim of this work is to study the performance of a 5 mm thick cross-strip CdZnTe detector with different electrode widths. Our study consists of two main parts, simulations and experiments. We utilized four different anode sizes ranging from 0.1 mm to 0.6 mm. The anodes were interspersed with steering electrodes with varying sizes from 0.3 mm to 0.85 mm. The maximum gap size between the anodes and steering electrode strips was set to 0.3 mm, while the minimum gap size was 0.125 mm. The performance of the detector was investigated in terms of the steering electrode bias voltage, the energy resolution, and the charge sharing effect. For simulations, we developed a C++ based simulation program for charge transport inside the CdZnTe detector and charge collection at the electrodes. For photon interactions we used GEANT4 toolkit and for electric field and weighting potential simulations we used COMSOL software. The results demonstrated that -50 V is the optimal steering electrode bias for our detector when -500 V was applied to the cathodes and that the energy resolution performance drops with increasing steering electrode width. Also, the charge sharing effect becomes more dominant for larger steering electrode sizes. The experimental result are further compared with the simulations. The results are in a good agreement and the comparison validates our simulation model. Although, our simulation framework has need of better estimation for the intrinsic noise of CdZnTe. These results suggest that an optimization study between electrode widths and steering electrode bias is required to obtain the best performance in orthogonal-strip CdZnTe detectors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑