Silicon Photo-multipliers (SiPMs) are very sensitive photo-detectors that experienced a big development in the last years in several applications, like LIDAR, astrophysics, medical imaging and high energy physics (HEP) experiments. In HEP experiments, in particular, they are often exposed to significant radiation doses. The main purpose of this manuscript is the characterization of several FBK SiPM technologies when exposed to 74 $MeV$ protons with a total fluence comparable to the one that they would experience in space along circular Low Earth Orbits (LEO), Polar, during a five years mission.
In this work, we estimated the expected proton fluences along the selected orbit, by means of the SPENVIS software. Several fluence steps were chosen to consider dense fluence intervals and have a more accurate sight on the whole damage process. We estimated a maximum fluence achieved during the tests of $6.4 \times 10^{11}$ $n_{eq}/cm^2$. Based on such simulations, we irradiated several SiPM technologies. We developed a custom experimental setup, which was used to perform online reverse voltage-current, right after each irradiation step, to minimize the effect of the annealing on the measurement.
The results are then displayed, in particular the currents, the noise and the Photon Detection Efficiency. Also a 30-days study on the annealing of the devices was performed.
Lastly, the conclusions are drawn on the basis of the Signal-to-Noise Ratio (SNR), taking into account the standard parameters of famous satellites using similar orbits as the ones considered into this work.
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and breakdown voltage of SiPMs exposed to a reactor neutron fluence up to $Φ$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $μ$m. Results of the measurements and analysis of the IV-curves are presented. Impact of the self-heating effect was investigated. The radiation damage uniformity of 1 cell and 120 cells was checked up to $U_\mathit{ov}$ = 1.7 V. Fluence dependence of the breakdown voltage from the current measurements $U^{IV}_\mathit{bd}$ was extracted and compared to th…
The use of Silicon Photo-Multipliers(SiPMs)has become popular in the design of High Energy Physics experimental apparatus with a growing interest for their application in detector area where a significant amount of non-ionising dose is delivered. For these devices, the main effect caused by the neutron fluence is a linear increase of the leakage current. In this paper, we present a technique that provides a partial recovery of the neutron damage on SiPMs by means of an Electrical Induced Annealing. Tests were performed, at the temperature of 20C, on a sample of three SiPM arrays (2x3) of 6 mm^…
The current understanding of radiation tollerance of Silicon Photomultipliers (SiPMs) is reviewd. Radiation damage in silicon sensors is briefly introduced, surface and bulk effects are separately addressed. Results on the operation of irradiated SiPMs with X-ray, gamma, electron, proton and neutron sources are presented. The most critical effect of radiation on SiPMs is the increase of dark count rate, which makes it impossible to resolve signals generated by a single photon from the noise. Methods to characterize irradiated SiPMs after their single photo-electron resolution is lost are discu…
This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $Φ_\mathrm{e^-}\approx 3 \times 10^…
We report on the measurement of the radiation hardness of silicon photomultipliers (SiPMs) manufactured by Fondazione Bruno Kessler in Italy (1 mm$^2$ and 6.2 mm$^2$), Center of Perspective Technology and Apparatus in Russia (1 mm$^2$ and 4.4 mm$^2$), and Hamamatsu Corporation in Japan (1 mm$^2$). The SiPMs were irradiated using a beam of 212 MeV protons at Massachusetts General Hospital, receiving fluences of up to $3 \times 10^{10}$ protons per cm$^2$ with the SiPMs at operating voltage. Leakage currents were read continuously during the irradiation. The delivery of the protons was paused pe…
Recently, silicon photomultipliers (SiPMs) have been used in several space-borne missions, owing to their solid state, compact size, low operating voltage, and insensitivity to magnetic fields. However, operating SiPMs in space results in radiation damage and degraded performance. In-orbit quantitative studies on these effects are limited. In this study, we present in-orbit SiPM characterization results obtained by the second detector of the Gamma-Ray Integrated Detectors (GRID-02), which was launched on 6 November 2020. An increase in dark current of $\sim$100 $μ$A/year per SiPM chip (model M…
The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating studies were performed with a KETEK SiPM, glued on an Al$_2$O$_3$ substrate, which is either directly connected to the temperature-controlled chuck of a probe station, or through layers of material with well-known thermal resistance. The SiPM is illuminated by a LED operated in DC-mode. The SiPM current is measured and used to determine the steady-state temper…
The characterisation of radiation-damaged SiPMs is a major challenge, when the average time between dark counts approaches, or even exceeds, the signal decay time. In this note a collection of formulae is presented, which have been developed and used for the analysis of current measurements for SiPMs in the dark and illuminated by an LED, before and after hadron irradiation. It is shown, how parameters like the breakdown voltage, the quenching resistance, the dark-count rate, the reduction of the photo-detection efficiency due to dark counts and the Geiger discharge probability can be estimate…
Silicon Photo-Multipliers (SiPM) are becoming the photo-detector of choice for increasingly more particle detection applications, from fundamental physics to medical and societal applications. One major consideration for their use at high-luminosity colliders is the radiation damage induced by hadrons, which leads to a dramatic increase of the dark count rate. KETEK SiPMs have been exposed to various fluences of reactor neutrons up to $Φ_{neq}$ = 5$\times$10$^{14}$ cm$^{-2}$ (1 MeV equivalent neutrons). Results from the I-V, and C-V measurements for temperatures between $-$30$^\circ$C and $+$3…
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have shown to be susceptible to radiation damage. SensL SiPMs with different cell sizes were irradiated with 64 MeV protons and 8 MeV electrons. In general, results show larger cell sizes are more susceptible to radiation damage with the largest 50 um SiPMs showing the greatest increase in current as a function of dose. Current increases were observed for doses as…
New pixel geometries are on the rise to achieve high sensitivity in near-infrared wavelengths with silicon photomultipliers (SiPMs). We test prototypes of the tip avalanche photo-diodes, which feature a quasi-spherical p-n junction and a high photodetection efficiency over a wide spectral range, and analyze the performance after neutron irradiation. The observed increase in dark count rate is significantly smaller than for a SiPM with a conventional design, indicating a good radiation hardness of the pixel geometry.
Radiation damage of J-series silicon photomultipliers (SiPMs) has been studied in the context of using these photodetectors in future space-borne scintillation detectors. Several SiPM samples were exposed to 101.4 MeV protons, with 1 MeV neutron equivalent fluence ranging from 1.27*10^8 n/cm^2 to 1.23*10^10 n/cm^2 . After the irradiation, the SiPMs experienced a large increase in the dark current and noise, which may pose problems for long-running space missions in terms of power consumption, thermal control and detection of low-energy events. Measurements performed with a CeBr3 scintillator c…
Prototype SiPMs with 4384 pixels of dimensions $15 \times 15~μ$m$^2$ produced by KETEK have been irradiated with reactor neutrons to eight fluences between $10^9$ and $5\times 10^{14}$ cm$^{-2}$. For temperatures between $-30~^\circ $C and $+30~^\circ $C capacitance-voltage, admittance-frequency, current-forward voltage, current-reverse voltage and charge-voltage measurements with and without illumination by a sub-nanosecond laser have been performed. The data have been analysed using different methods in order to extract the dependence on neutron fluence and temperature of the electrical para…
Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to b…
CLLBC(Ce) and TLYC(Ce) are novel scintillation materials capable of measuring mixed gamma ray and neutron radiation fields that have gained significant interest in the areas of space and nuclear safety/security science. To date Geant4, the world's most popular Monte Carlo radiation modelling toolkit, has yet to be effectively used to simulate the full response of these materials when coupled to near ultra-violet Silicon PhotoMultipliers (SiPMs). In this work an experimentally validated Geant4 application has been developed with optimised material composition, optical data tables, and physics t…
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher detection efficiency, insensitivity to magnetic fields and mechanical robustness to launch vibrations. All these features make SiPMs ideal for use on space based experiments where the detectors require to be compact, lightweight and capable of surviving launch conditions. A downside with the use of this novel type of detector in space conditions is its susce…
The silicon photo-multipliers (SiPMs) are commonly used in the construction of radiation detectors such as those used in high energy experiments and its applications, where an excellent time resolution is required for triggering. In most of this cases, the trigger systems electric charge information is discarded due to limitations in data acquisition. In this work we propose a method using a simple radiation detector based on an organic plastic scintillator $2\times2\times0.3$~cm$^3$ size, to estimate the electric charge obtained from the acquisition of the fast output signal of a SensL SiPM m…
A dedicated single-cell SiPM structure is designed and measured to investigate the radiation damage effects on the gain and turn-off voltage of SiPMs exposed to a reactor neutron fluence up to $Φ$ = 5e13 cm$^{-2}$. The cell has a pitch of 15 $μ$m. The fluence dependence of gain and turn-off voltage are reported. A reduction of the gain by 19% and an increase of $V_{off}$ by $\approx$0.5 V is observed after $Φ$ = 5e13 cm$^{-2}$.
The necessity to use Photo Multipliers (PM) as light detector limited in the past the use of crystals in radiation handled device preferring the Geiger approach. The Silicon Photomultipliers (SiPMs) are very small and cheap, solid photon detectors with good dynamic range and single photon detection capability, they are usable to supersede in some application cumbersome and difficult to use Photo Multipliers (PM). A SiPM can be coupled with a scintillator crystal to build efficient, small and solid radiation detector. A cost effective and easily replicable Hardware software module for SiPM dete…
We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-annealing were performed on Hamamatsu SiPMs using a calibrated Am-Be neutron source from the Jefferson Lab Radiation Control group. As the result of irradiation both dark current and dark rate increase …
The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of MPPCs from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at Brookhaven National Lab and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10$^8$ n/cm$^2$ to 10$^{12}$ n/cm$^2$. The main effect of gamma ray damage is an increase in the noise and leakage curren…
Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They are already successfully utilized in Projectile Spectator Detector (PSD) of NA61 at CERN, and will be utilized soon in PSD of CBM at FAIR and Forward Hadron CALorimeters (FHCAL) of BM@N at NICA heavy-ion collision experiments. The main issue of SiPM application is their degradation due to high neutron fluence that can reach up to 2E11 neq/cm2 per year of the e…
Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based radiation detectors for Single Photon Emission Computed Tomography (SPECT) applications have been explored, and even fewer experimental prototypes developed. An in-silico investigation into the optimal design of a Philips DPC3200 SiPM photosensor-based thin monolithic scintillator detector for SPECT applications was undertaken using the Monte Carlo radiatio…
Silicon photomultipliers (SiPM) are solid state light detectors with sensitivity to single photons. Their use in high energy physics experiments, and in particular in ring imaging Cherenkov (RICH) detectors, is hindered by their poor tolerance to radiation. At room temperature the large increase in dark count rate makes single photon detection practically impossible already at 10$^{11}$ cm$^{-2}$ 1-MeV-equivalent neutron fluence. The neutron fluences foreseen by many subdetectors to be operated at the high luminosity LHC range up to 10$^{14}$ cm$^{-2}$ 1-MeV-equivalent. In this paper we presen…
ALDO2 is a multi-function, adjustable, low dropout linear regulator designed in onsemi I3T80 0.35~$μ$m HV CMOS technology for use in HEP detectors that adopt silicon photomultipliers (SiPMs). The chip features four independent regulators, two low voltage channels (max 3.3 V) used to filter and stabilize the power supply of front-end chips, and two HV channels (max 70 V), specifically designed to provide the bias voltage to arrays of SiPMs. Each regulator can be independently shut down and is protected for over-current and over-temperature. The HV regulators also implement a circuit to monitor …
Using a 20 MeV linear accelerator, we investigate the effects of electromagnetic radiation on the optical transparency of F8 lead glass. Specifically, we measure the change in attenuation length as a function of radiation dose. Comparing our results to similar work that utilized a proton beam, we conclude that F8 lead glass is more susceptible to proton damage than electron damage.
Kinetics of radiation damage of the PWO crystals under irradiation and recovery were studied. Crystals were irradiated with dose corresponding to average one expected in the electromagnetic calorimeter (working dose irradiation). Radiation damage and recovery were monitored through measurements of PWO optical transmission. An approach is proposed which allows evaluating the influence of the PWO crystals properties on the statistical term in the energy resolution of the electromagnetic calorimeter. The analysis also gives important information about the nature of the radiation damage mechanism …
The motivation for investigating the use of GaAs as a material for detecting particles in experiments for High Energy Physics (HEP) arose from its perceived resistance to radiation damage. This is a vital requirement for detector materials that are to be used in experiments at future accelerators where the radiation environments would exclude all but the most radiation resistant of detector types.
To address the challenges of providing high performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCChh environments), we are conducting R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we are focusing our attention on ultra-compact radiation hard EM calorimeters, based on modular structures (RADiCAL modules) consisting of alternating layers of very dense absorber and scintillating plates, …
Hamamatsu photomultiplier tubes (PMT) and various PMT window materials were exposed to gamma irradiation. Tests were performed with absorbed doses of 1 krad and 120 krad. Initial recommendations on PMT types to use in the BTeV electromagnetic calorimeter are stated.
Cs$_2$LiYCl$_6$:Ce$^{3+}$ (CLYC) is a new scintillator that is an attractive option for applications requiring the ability to detect both gamma rays and neutrons within a single volume. It is therefore of interest in applications that require low size, weight, or power, such as space applications. The radiation environment in space can over time damage the crystal structure of CLYC, leading to reduced performance. We have exposed 2 CLYC samples to 800 MeV protons at the Los Alamos Neutron Science Center, one to approximately 10 kRad and one to approximately 100 kRad. We measured the pulse shap…
In this work we study the performance of silicon photomultiplier (SiPM) light sensors after exposure to the JULIC cyclotron proton beam, of energy $\sim$ 39 MeV, relative to their performance before exposure. The SiPM devices used in this study show a significant change in their behavior and downward shift of their breakdown voltage by as much as $\sim$ 0.4$\pm$0.1 V. Single photon measurements appear to be no longer possible for the SiPMs under study after exposure to a dose of $\sim$ 0.2 Gy (corresponding to an integrated proton flux of $\sim$$ϕ_{p}$=1.06x10$^{8}$ p/cm$^{2}$). No visible dam…
Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations.
POLAR-2 is a space-borne polarimeter, built to investigate the polarization of Gamma-Ray Bursts and help elucidate their mechanisms. The instrument is targeted for launch in 2024 or 2025 aboard the China Space Station and is being developed by a collaboration between institutes from Switzerland, Germany, Poland and China. The instrument will orbit at altitudes between 340km and 450km with an inclination of 42$^{\circ}$ and will be subjected to background radiation from cosmic rays and solar events. It is therefore pertinent to better understand the performance of sensitive devices under space-…
The report contains various aspects of radiation damage in silicon detectors subjected to high intensity hadron and electromagnetic irradiation. It focuses on improvements for the foreseen LHC applications, employing oxygenation of silicon wafers during detector processing (result from CERN-RD48). An updated survey on hadron induced damage is given in the first article. Several improvements are outlined especially with respect to antiannealing problems associated with detector storage during LHC maintenance periods. Open questions are outlined in the final section, among which are a full under…
The absorption length, $λ_{abs}$, of light with wavelengths between 0.95 and 1.30$~μ$m in silicon irradiated with 24$~$GeV/c protons to 1$~$MeV neutron equivalent fluences between 0 and $8.6 \times 10^{15}~$cm$^{-2}$ has been measured. It is found that $λ_{abs}$ decreases with fluence due to radiation-induced defects. A phenomenological parametrisation of the radiation-induced change of $λ_{abs}$ as a function of wavelength and neutron equivalent fluence at room temperature is given. The observation of the decrease of $λ_{abs}$ with irradiation is confirmed by edge-TCT measurements on irradiat…
Quartz capillary tube/fibers have been filled with anthracene by a melt and vacuum inbibition process to fabricate a scintillating core fiber. Other polcyclic aromatic hydrocarbons(PAH), such as p-Terphenyl (pTP), stilbene or naphthalene are also well-suited to scintillating/shifting fiber cores. The resulting scintillating core with quartz cladding capillary fibers (250-750 micron cores) had a high specific light output when tested with muons (8 p.e. per MIP). These PAH core quartz capillary cladding scintillating/shifting optical fibers have the potential of high radiation resistance, fast r…