使用塑料闪烁体与辐射损伤硅光电倍增管(SiPM)降低能量阈值

Lowering the Energy Threshold using a Plastic Scintillator and Radiation-Damaged SiPMs

Teruaki Morishita, Yasushi Fukazawa, Hiromitsu Takahashi, Taishu Kayanoki, Ryota Niwa, Masaki Hashizume

AI总结:

针对卫星轨道上SiPM辐射损伤导致闪烁体探测器能量阈值升高的问题,通过电流波形放大器、双SiPM符合求和及低温测量三种方法,可将受辐射损伤SiPM的能量阈值降至原有的约15%。

摘要:

卫星轨道上的硅光电倍增管(SiPM)受到辐射损伤会提高闪烁体探测器的能量阈值。本研究证实,1 krad的辐射会使能量阈值升高约10倍,这对我们的系统而言是最不利的情况。为最大程度降低受辐射损伤SiPM的能量阈值,我们采用1至2个经质子辐照损伤的SiPM搭配塑料闪烁体,开展了以下三项实验:(1)使用电流波形放大器替代电荷灵敏放大器进行测量;(2)将两个受辐射损伤的SiPM耦合至同一闪烁体,对二者信号求和并开展符合测量;(3)低温环境下的测量。研究结果表明,与电荷灵敏放大器加成形放大器的组合相比,采用电流波形放大器可将能量阈值降至约65%(从198 keV降至128 keV)。此外,在符合测量中合理设置符合宽度并对两个SiPM的信号求和,与仅使用单个闪烁体的情况相比,可在采集信号几乎无损失的前提下,将能量阈值降至约70%(从132 keV降至93 keV)。最后,在-20 °C温度下进行测量时,相较于20 °C的情况,能量阈值可降至约34%(从128 keV降至43 keV)。据此我们得出结论:结合这三种方法,可将能量阈值降至约15%。

英文摘要:

The radiation damage to a silicon photomultiplier (SiPM) set on a satellite orbit increases energy threshold for scintillator detectors. We confirmed that 1 krad of radiation increases the energy threshold by approximately a factor of 10, which is worst for our system. Using one or two SiPMs damaged by proton irradiation and a plastic scintillator, we performed the following three experiments in our attempt to lower the energy threshold of radiation-damaged SiPMs to the greatest extent: (1) measurements using a current waveform amplifier rather than a charge-sensitive amplifier, (2) coincidence measurements with two radiation-damaged SiPMs attached to one scintillator and summing up their signals, and (3) measurements at a low temperature. Our findings confirmed that the use of a current waveform amplifier, as opposed to a charge-sensitive amplifier and a shaping amplifier, could lower the energy threshold to approximately 65% (from 198 keV to 128 keV). Furthermore, if we set the coincidence width appropriately and sum up the signals of the two SiPMs in the coincidence measurement, the energy threshold could be lowered to approximately 70% (from 132 keV to 93 keV) with little loss of the acquired signal, compared to that of use of only one scintillator. Finally, if we perform our measurements at a temperature of -20 °C, we could lower the energy threshold to approximately 34% (from 128 keV to 43 keV) compared to that of at 20 °C. Accordingly, we conclude that the energy threshold can be lowered to approximately 15% by using a combination of these three methods.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑