Ahigh-granularity scintillator calorimeter readout with silicon photomultipliers (SiPMs) is an electromagnetic calorimeter (ECAL) candidate for experiments at the Circular Electron Positron Collider (CEPC). A critical design parameter of this ECAL candidate is the dynamic range of the SiPMs. This study investigates the SiPM dynamic range required for the CEPC scintillator ECAL. A model is developed on the basis of the operation principles of SiPMs to describe the response of an SiPM to light pulses within one recovery period by considering the cross-talk effect, photon detection efficiency, and number of pixels. The response curve of a 10000-pixel SiPM predicted by the model is consistent with the measured curve within 2% for an incident light pulse of up to 12000 photons. The intrinsic fluctuations of the SiPM response naturally exist in this model, and the correction of the saturation effect in the SiPM response is investigated. Monte Carlo (MC) simulation shows that the algorithm can restore the response linearity of an SiPM for an incident light pulse in which the number of photons is up to around six times the number of SiPM pixels. The model and correction program are implemented for full simulation of the ZH production Z->vv, H->yy channel to evaluate the impact of the SiPM dynamic range of the CEPC scintillator ECAL on the reconstructed Higgs boson mass and the sensitivity to the Higgs signal in this channel. The results show that the CEPC scintillator ECAL equipped with no less than 4000 SiPM pixels and operated with a light yield of 20 photon-electrons per channel for a single minimum ionizing particle can meet the requirements for Higgs boson precision measurement in the di-photon channel at the CEPC.
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected tim…
Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They are already successfully utilized in Projectile Spectator Detector (PSD) of NA61 at CERN, and will be utilized soon in PSD of CBM at FAIR and Forward Hadron CALorimeters (FHCAL) of BM@N at NICA heavy-ion collision experiments. The main issue of SiPM application is their degradation due to high neutron fluence that can reach up to 2E11 neq/cm2 per year of the e…
The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active material (SiPM-on-tile). The front-end chips are integrated into the active layers of the calorimeter and are designed for minimizing power consumption by rapidly cycling the power according to the beam structure of a linear accelerator. 38 layers of the sampling structure are equipped with cassettes containing 5…
Hadron calorimeter (HCAL) is an essential sub-detector of the baseline detector system for Circular Electron Positron Collider (CEPC). We plan to build an Analog Hadron CALorimeter (AHCAL) prototype based on the Particle Flow Algorithm (PFA). The AHCAL of CEPC uses steel as absorber and scintillator tiles read out by Silicon Photo-Multipliers (SiPMs) as sensitive medium. The energy linearity and resolution of the calorimeter depends on the light yield uniformity of sensitive medium. It is essential to qualify the entire detector production in order to select scintillator tiles with light yield…
As a future Higgs or Z factory, construction of the circular electron positron collider(CEPC) has been proposed to precisely measure Higgs bosons. A particle flow-oriented electromagnetic calorimeter (ECAL) and a hadronic calorimeter comprise a baseline design for the CEPC calorimetry system. The scintillator-tungsten ECAL (Sc-ECAL) prototype is being developed within the CEPC calorimetry working group. The Sc-ECAL is a sampling calorimeter consisting of alternating absorber layers and high granularity active layers. Each component of the active layer has been studied and optimized from a vari…
CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory. Calorimeter is the main part of this experiment to measure the jet energy. Semi-digital hadron calorimeter (SDHCAL) is one of the options for the hadron measurement. GEM detector with its high position resolution and flexible configuration is one of the candidates for the active layer of the SDHCAL. The main purpose of this paper is to provide a feasible readout method for the GEM-based semi-digital hadron calorimete…
A novel perspective on crystal electromagnetic calorimeter design for the CEPC
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);High Energy Research Center, Henan Academy of Sciences(河南省科学院高能研究中心);Luoyang Mining Machinery Engineering Design Institute CO.,LTD(洛阳矿山机械工程设计研究院有限责任公司);China Center of Advanced Science and Technology(中国高等科学技术中心)
In this paper, we describe the first tests of a dual-readout fiber calorimeter in which silicon photomultipliers are used to sense the (scintillation and Cherenkov) light signals. The main challenge in this detector is implementing a design that minimizes the optical crosstalk between the two types of fibers, which are located very close to each other and carry light signals that differ in intensity by about a factor of 60. The experimental data, which were obtained with beams of high-energy electrons and muons as well as in lab tests, illustrate to what extent this challenge was met. The Cher…
Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $20…
The Analogue Hadron Calorimeter (AHCAL) is being developed within the CALICE collaboration for experiments at a future lepton collider. It is a sampling calorimeter with alternating layers of steel absorber plates and plastic scintillator tiles as active material. In the SiPM on tile design, the tiles are directly coupled to silicon photomultipliers (SiPMs). The front-end electronics are integrated into the active layers of the calorimeter. They are designed for low power consumption by rapidly power cycling according to the beam structure of a linear accelerator. In 2017 and 2018, a new large…
The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on…
The SiPM-on-tile technology, consisting of plastic scintillator tiles with typical sizes of a few cm$^2$ mounted on top of SiPMs, has been developed within the CALICE collaboration to enable automatized mass production of active elements for scintillator-based highly granular calorimeters. We present a study of the impact of misalignment of the scintillator tile with respect to the photon sensor on the response uniformity and on the absolute light yield for square, hexagonal and rhomboidal scintillator tiles of different sizes. A misalignment results in the formation of a dipole asymmetry of t…
With the successful construction and operation of a highly granular hadron calorimeter system, featuring approx. 22000 individually read out SiPM-on-tile channels, the CALICE collaboration has set the next milestone in proving the scalability of the concept for a future high energy linear collider experiment. For this large sample of photosensors a new approach of quality control was required to sufficiently characterise and monitor device parameters for both, test bench and in-situ beam test data. In the presence of temperature fluctuations during operation, it was possible to stabilise the S…
The CALICE collaboration is developing highly granular electromagnetic and hadronic calorimeters for detectors at future energy frontier electron-positron colliders. After successful tests of a physics prototype, a technological prototype of the Analog Hadron Calorimeter has been built, based on a design and construction techniques scalable to a collider detector. The prototype consists of a steel absorber structure and active layers of small scintillator tiles that are individually read out by directly coupled SiPMs. Each layer has an active area of $72 \times 72\,{\rm cm}^{2}$ and a tile siz…
The design and optimization of the Electromagnetic Calorimeter (ECAL) are crucial for the Circular Electron Positron Collider (CEPC) project, a proposed future Higgs/Z factory. Following the reference design of the International Large Detector (ILD), a set of silicon-tungsten sampling ECAL geometries are implemented into the Geant4 simulation, whose performance is then scanned using Arbor algorithm. At single particle level, the photon energy response at different ECAL longitudinal structures is analyzed. At bi-particle sample, the separation performance with different ECAL transverse cell siz…
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current incre…
Conceptual Design of a Novel Highly Granular Crystal Electromagnetic Calorimeter for Future Higgs Factories
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);State Key Laboratory of Particle Detection and Electronics(粒子探测与电子学国家重点实验室);University of Chinese Academy of Sciences(中国科学院大学);China Center of Advanced Science and Technology(中国高等科学技术中心);Institute of Nuclear and Particle Physics, School of Physics and Astronomy, Shanghai Jiao Tong University(上海交通大学物理与天文学院核物理与粒子物理研究所);Tsung-Dao Lee Institute, Shanghai Jiao Tong University(上海交通大学李政道研究所);National Key Laboratory of Dark Matter Physics, Shanghai Key Laboratory for Particle Physics and Cosmology, Key Laboratory for Particle Astrophysics and Cosmology (MoE)(暗物质物理全国重点实验室、粒子物理与宇宙学上海市重点实验室、粒子天体物理 cosmology 教育部重点实验室)
Photon reconstruction using the Hough transform in imaging calorimeters
Institute of High Energy Physics(高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);High Energy Research Center, Henan Academy of Sciences(河南省科学院高能研究中心);China Center of Advanced Science and Technology(中国高等科学技术中心)
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The…
The motivation of the current R&D project is based upon the requirements of the JEDI international collaboration aiming to measure Electric Dipole Moments (EDMs) of charged particles in storage rings. One of the most important elements of such an experiment will be a specially designed polarimeter with the detection system based on a modular inorganic scintillator (LYSO crystal) calorimeter. The calorimeter modules are read out by Silicon Photo Multipliers (SiPMs). This paper describes the development of a multi-channel power supply for the polarimeter modules, providing very stable and clean …