Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);High Energy Research Center, Henan Academy of Sciences(河南省科学院高能研究中心);Luoyang Mining Machinery Engineering Design Institute CO.,LTD(洛阳矿山机械工程设计研究院有限责任公司);China Center of Advanced Science and Technology(中国高等科学技术中心)

Weizheng Song, Yang Zhang, Shengsen Sun, Fangyi Guo, Yuanzhan Wang, Linghui Wu, Jie Guo, Shaojing Hou, Yong Liu, Quan Ji, Jinfan Chang, Yifang Wang

AI总结:

本文提出了一种新的晶体 ECAL 设计,通过几何重构和模块交错结构,实现高能量分辨率和三维 shower 成像,适用于 PFA 指导的探测器系统。

摘要:

晶体电磁 calorimeters(ECALs)对于粒子物理实验中电子和光子的高精度测量至关重要。然而,传统设计中长晶体棒径向指向相互作用区域且缺乏纵向分割,无法满足粒子流方法(PFA)所需的三维 shower 成像需求。我们提出了一种新的晶体 ECAL 设计视角以解决这一限制。关键创新是几何重构,晶体棒面向相互作用区域并相邻纵向层中正交排列。这种布局通过相关测量正交晶体棒的测量实现能量沉积的精细空间分割。引入了正则和倒置梯形模块的交错结构以最大化结构均匀性和探测器密封性。该设计旨在保持晶体 ECAL 的优异固有能量分辨率,同时提供 PFA 所需的详细三维 shower 成像。模拟结果证实了实现优异能量分辨率为 $1.14\%/\sqrt{E} \oplus 0.44\%$ 的可行性。因此,所提设计将晶体 ECAL 重新定位为面向 PFA 的探测器系统在 CEPC 等设施中的基础组件,提供了一条推进未来对撞机物理目标的新技术路径。

英文摘要:

Crystal electromagnetic calorimeters (ECALs) are essential for high-precision measurements of electrons and photons in particle physics experiments. However, the conventional design, in which long crystal bars point radially toward the interaction region and lack longitudinal segmentation, is incompatible with the three-dimensional shower imaging required by Particle Flow Approach (PFA). We propose a novel perspective on crystal ECAL design to address this limitation. The key innovation is a geometric reconfiguration in which crystal bars are oriented to face the interaction region and arranged orthogonally in adjacent longitudinal layers. This layout achieves fine spatial segmentation of energy deposits by correlating measurements of orthogonal crystal bars. An interleaved structure of regular and inverted trapezoidal modules is incorporated to maximize structural uniformity and detector hermeticity. This design is engineered to preserve the excellent intrinsic energy resolution of crystal ECALs while simultaneously providing the detailed three-dimensional shower imaging essential for PFA. Simulation results confirm the feasibility of achieving excellent energy resolution of $1.14\%/\sqrt{E} \oplus 0.44\%$. Consequently, the proposed design repositions crystal ECAL as a foundational component for PFA-oriented detector systems at facilities such as the Circular Electron Positron Collider (CEPC), offering a new technical pathway to advance the physics goals of future colliders.