γ-中子比的测量通过脉冲形状歧视(PSD)的钚铍(PuBe)源和一个基本的构造的钋铍(PoBe)源使用一个有机液体闪烁体探测器和数字信号处理。此外,两个有机液体闪烁体探测器和数字信号处理被用来进行符合计数的PoBe源。测量数据与文献进行比较。发现PuBe和PoBe源的伽马与中子源的比率分别为3.67 +/- 0.14和1.13 +/- 0.05。两个比率均高于相应中子源的文献值。符合计数分析表明,PoBe源发射两个或更多个符合的伽马射线或中子,置信水平为91.77%,使用40 ns的符合窗口和1 mm的探测器源距离。

英文摘要:

The gamma to neutron ratio is measured via Pulse Shape Discrimination (PSD) of a Plutonium Beryllium (PuBe) source and of a rudimentary constructed Polonium Beryllium (PoBe) source using one organic liquid scintillator detector and digital signal processing. Furthermore, two organic liquid scintillator detectors and digital signal processing is used to conduct coincidence counting on the PoBe source. Measured data is compared to literature. The gamma to neutron source ratio was found to be 3.67 +/- 0.14 and 1.13 +/- 0.05 for the PuBe and for the PoBe source respectively. Both ratios are above literature values for the respective neutron sources. Coincidence counting analysis showed that the PoBe source emitted two or more coincident gamma-rays or neutrons with a confidence level of 91.77 % using a coincident window of 40ns and a detector source distance of 1 mm.