Fourier ptychography microscopy (FPM), sharing its roots with synthetic aperture technique and phase retrieval method, is a recently developed computational microscopic super-resolution technique. By turning on the light-emitting diode (LED) elements sequentially and acquiring the corresponding images that contain different spatial frequencies, FPM can achieve a wide field-of-view (FOV), high-spatial-resolution imaging, and phase recovery simultaneously. Conventional FPM assumes that the sample is sufficiently thin and strictly in focus. Nevertheless, even for a relatively thin sample, the non-planar distribution characteristics and the non-ideal position/posture of the sample will cause all or part of FOV to be defocused. In this paper, we proposed a fast digital refocusing and depth-of-field (DOF) extended FPM strategy by taking the advantages of image lateral shift caused by sample defocusing and varied-angle illuminations. The lateral shift amount is proportional to the defocus distance and the tangent of the illumination angle. Instead of searching the optimal defocus distance in optimization strategy, which is time-consuming, the defocus distance of each subregion of the sample can be precisely and quickly obtained by calculating the relative lateral shift amounts corresponding to different oblique illuminations. And then, the digital refocusing strategy rooting in the Fresnel propagator is integrated into the FPM framework to achieve the high-resolution and phase information reconstruction for each part of the sample, which means the DOF the FPM is effectively extended. The feasibility of the proposed method in fast digital refocusing and FOV extending is verified in the actual experiments with the USAF chart and biological samples.
Three-dimensional virtual refocusing of fluorescence microscopy images using deep learning
University of California, Los Angeles(加利福尼亚大学洛杉矶分校);California Nano Systems Institute (CNSI)(加州纳米系统研究所);David Geffen School of Medicine(大卫·格芬医学院);Hebrew University of Jerusalem(耶路撒冷希伯来大学)
Experimental robustness of Fourier Ptychography phase retrieval algorithms
University of California, Berkeley(加州大学伯克利分校);École Normale Supérieure(巴黎高等师范学院);Colorado School of Mines(科罗拉多矿业学院);University of Southern California(南加州大学)
无标记纳米显微镜包括使用可见波长的分辨率在100 nm范围内的光学成像。在这里,我们提出了一种无标签的纳米显微镜方法,结合傅立叶重叠关联与波导显微镜实现“超级聚光器”,其特征在于最大程度地倾斜相干暗场照明与人工拉伸波矢量,由于大的折射率的就业硅$_3$ N $_4$波导材料。我们通过锥形单模波导在尺寸为400 $\mathrmμ$ m $^2$的成像区域上产生傅立叶重叠关联成像所需的相干平面波照明,并双重处理傅立叶重叠关联相位恢复算法的重叠约束:首先通过波导芯片布局的复用输入结构依次改变照明波矢量的方向性,通过在可见光谱上逐步增加照明光波长来缩短波矢量模量。我们通过计算机和体外实验验证了该方法,并提供了有关基本图像形成理论和重建算法的详细信息。
Spatially-coded Fourier ptychography: flexible and detachable coded thin films for quantitative phase imaging with uniform phase transfer characteristics
Wide-field, high-resolution lensless on-chip microscopy via near-field blind ptychographic modulation
提出了一种基于近场盲重叠关联调制的无透镜片上显微平台。在这个平台中,我们在物体和图像传感器之间放置了一个薄的漫射器,用于光波调制。通过盲扫描未知漫射器到不同的x-y位置,我们获得了一系列调制强度图像,用于定量对象恢复。与之前的重叠关联成像实现不同,我们采用了菲涅尔数约为50,000的单位放大配置,这比之前的重叠关联成像设置高出几个数量级。单位放大率配置允许我们将整个传感器区域(6.4 mm × 4.6 mm)作为成像视场。超高的菲涅尔数使我们能够直接恢复的相位恢复过程中的扩散器的位置偏移,解决了定位精度问题困扰在定期重叠关联实验。在我们的实现中,我们使用一个低成本的,DIY的扫描阶段,以执行盲漫射器调制。精确的机械扫描,这是传统的重叠关联实验中的关键是不再需要在我们的设置。我们还采用了上采样相位恢复方案,以绕过成像器像素大小设置的分辨率限制,并展示了0.78微米的半间距分辨率。我们通过体外细胞培养、透明和染色的组织切片以及厚的生物样品来验证成像性能。我们表明,恢复的定量相位图可以用来执行有效的细胞分割的密集的酵母培养。我们还展示了基于恢复的波前的厚生物样品的3D数字重聚焦。该平台为大视场、高分辨率和定量的片上显微镜提供了一种具有成本效益的交钥匙解决方案。
Gap-free Information Transfer in 4D-STEM via Fusion of Complementary Scattering Channels
Delft University of Technology(代尔夫特理工大学);Thermo Fisher Scientific(赛默飞世尔科技);DSTL GmbH(DSTL有限公司);Institute of Science and Technology Austria (ISTA)(奥地利科学和技术研究所);Indiana University(印第安纳大学)