Fourier ptychography (FP) is a recently proposed computational imaging technique for high space-bandwidth product imaging. In real setups such as endoscope and transmission electron microscope, the common sample motion largely degrades the FP reconstruction and limits its practicability. In this paper, we propose a novel FP reconstruction method to efficiently correct for unknown sample motion. Specifically, we adaptively update the sample's Fourier spectrum from low spatial-frequency regions towards high spatial-frequency ones, with an additional motion recovery and phase-offset compensation procedure for each sub-spectrum. Benefiting from the phase retrieval redundancy theory, the required large overlap between adjacent sub-spectra offers an accurate guide for successful motion recovery. Experimental results on both simulated data and real captured data show that the proposed method can correct for unknown sample motion with its standard deviation being up to 10% of the field-of-view scale. We have released our source code for non-commercial use, and it may find wide applications in related FP platforms such as endoscopy and transmission electron microscopy.
Fourier ptychography (FP), as a computational imaging method, is a powerful tool to improve imaging resolution. Camera-scanning Fourier ptychography extends the application of FP from micro to macro creatively. Due to the non-ideal scanning of the camera driven by the mechanical translation stage, the pose error of the camera occurs, greatly degrading the reconstruction quality, while a precise translation stage is expensive and not suitable for wide-range imaging. Here, to improve the imaging performance of camera-scanning Fourier ptychography, we propose a pose correction scheme based on cam…
In Fourier ptychography, multiple low resolution images are captured and subsequently combined computationally into a high-resolution, large-field of view micrograph. A theoretical image-formation model based on the assumption of plane-wave illumination from various directions is commonly used, to stitch together the captured information into a high synthetic aperture. The underlying far-field (Fraunhofer) diffraction assumption connects the source, sample, and pupil planes by Fourier transforms. While computationally simple, this assumption neglects phase-curvature due to non-planar illuminat…
This paper presents a microscopic imaging technique that uses variable-angle illumination to recover the complex polarimetric properties of a specimen at high resolution and over a large field-of-view. The approach extends Fourier ptychography, which is a synthetic aperture-based imaging approach to improve resolution with phaseless measurements, to additionally account for the vectorial nature of light. After images are acquired using a standard microscope outfitted with an LED illumination array and two polarizers, our vectorial Fourier Ptychography (vFP) algorithm solves for the complex 2x2…
Fourier ptychography has attracted a wide range of focus for its ability of large space-bandwidth-produce, and quantative phase measurement. It is a typical computational imaging technique which refers to optimizing both the imaging hardware and reconstruction algorithms simultaneously. The data redundancy and inverse problem algorithms are the sources of FPM's excellent performance. But at the same time, this large amount of data processing and complex algorithms also greatly reduce the imaging speed. In this article, we propose a parallel Fourier ptychography reconstruction framework consist…
Synthetic aperture radar (SAR) can measure the phase with antenna and microwave, which cannot be directly extended to visible light imaging due to phase lost. In this letter, we reported an active remote sensing with visible light via reflective Fourier ptychography (FP), termed coherent synthetic aperture imaging (CSAI), achieving high resolution, wide field-of-view (FOV) and phase recovery. A proof-of-concept experiment was reported with laser scanning and a collimator for the infinite object. Both smooth and rough objects are tested, and the spatial resolution increased from 15.6 um to 3.48…
Experimental robustness of Fourier Ptychography phase retrieval algorithms
University of California, Berkeley(加州大学伯克利分校);École Normale Supérieure(巴黎高等师范学院);Colorado School of Mines(科罗拉多矿业学院);University of Southern California(南加州大学)
Fourier ptychography microscopy(FP) is a recently developed computational imaging approach for microscopic super-resolution imaging. By turning on each light-emitting-diode (LED) located on different position on the LED array sequentially and acquiring the corresponding images that contain different spatial frequency components, high spatial resolution and quantitative phase imaging can be achieved in the case of large field-of-view. Nevertheless, FPM has high requirements for the system construction and data acquisition processes, such as precise LEDs position, accurate focusing and appropria…
Spatially-coded Fourier ptychography: flexible and detachable coded thin films for quantitative phase imaging with uniform phase transfer characteristics
无标记纳米显微镜包括使用可见波长的分辨率在100 nm范围内的光学成像。在这里,我们提出了一种无标签的纳米显微镜方法,结合傅立叶重叠关联与波导显微镜实现“超级聚光器”,其特征在于最大程度地倾斜相干暗场照明与人工拉伸波矢量,由于大的折射率的就业硅$_3$ N $_4$波导材料。我们通过锥形单模波导在尺寸为400 $\mathrmμ$ m $^2$的成像区域上产生傅立叶重叠关联成像所需的相干平面波照明,并双重处理傅立叶重叠关联相位恢复算法的重叠约束:首先通过波导芯片布局的复用输入结构依次改变照明波矢量的方向性,通过在可见光谱上逐步增加照明光波长来缩短波矢量模量。我们通过计算机和体外实验验证了该方法,并提供了有关基本图像形成理论和重建算法的详细信息。
Fourier ptychography microscopy (FPM), sharing its roots with synthetic aperture technique and phase retrieval method, is a recently developed computational microscopic super-resolution technique. By turning on the light-emitting diode (LED) elements sequentially and acquiring the corresponding images that contain different spatial frequencies, FPM can achieve a wide field-of-view (FOV), high-spatial-resolution imaging, and phase recovery simultaneously. Conventional FPM assumes that the sample is sufficiently thin and strictly in focus. Nevertheless, even for a relatively thin sample, the non…
Diffractive zone plate optics uses a thin micro-structure pattern to alter the propagation direction of the incoming light wave. It has found important applications in extreme-wavelength imaging where conventional refractive lenses do not exist. The resolution limit of zone plate optics is determined by the smallest width of the outermost zone. In order to improve the achievable resolution, significant efforts have been devoted to the fabrication of very small zone width with ultrahigh placement accuracy. Here, we report the use of a diffractometer setup for bypassing the resolution limit of z…
East China Normal University(华东师范大学);Chongqing Institute of East China Normal University(华东师范大学重庆研究院);Shanxi University(山西大学);Shanghai Research Center for Quantum Sciences(上海量子科学研究中心)
Acousto-optic imaging (AOI) enables optical-contrast imaging deep inside scattering samples via localized ultrasound-modulation of scattered light. While AOI allows optical investigations at depths, its imaging resolution is inherently limited by the ultrasound wavelength, prohibiting microscopic investigations. Here, we propose a novel computational imaging approach that allows to achieve optical diffraction-limited imaging using a conventional AOI system. We achieve this by extracting diffraction-limited imaging information from 'memory-effect' speckle-correlations in the conventionally dete…
We propose and demonstrate a new phase retrieval method for imaging through random media. Although methods to recover the Fourier amplitude through random distortions are well established, recovery of the Fourier phase has been a more difficult problem and is still a very active research area. Here, we show that by simply ensemble averaging shift-corrected images, the Fourier phase of an object obscured by random distortions can be accurately retrieved up to the diffraction limit. The method is simple, fast, does not have any optimization parameters, and does not require prior knowledge or ass…
We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens (e.g., using an infrared microscope). These errors arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent err…