We report a homebuilt ultra-high-vacuum (UHV) rotating sample manipulator with cryogenic cooling. The sample holder is thermally anchored to a built-in cryogenic cold head through flexible copper beryllium strips, permitting continuous sample rotation. A similar contact mechanism is implemented for the electrical wiring to the sample holder for thermometry. The apparatus thus enables continuous sample rotation at regulated cryogenic temperatures in a UHV environment. We discuss the potential applications of this apparatus for cryogenic sputtering.
High quality low leakage SINIS devices made of Al-AlMn-Al layers were fabricated for energy dispersive single photon detection. Information on different heat flow channels was extracted from the measured dynamics of detector signals due to X-ray events. At the optimum operation point, the extracted effective electron temperature decreased from 88 mK down to 43 mK due to self-cooling, roughly doubling the detector sensitivity.
Design, construction, and testing of the PandaX-xT cryogenics system
Shanghai Jiao Tong University(上海交通大学);Shanghai Jiao Tong University Sichuan Research Institute(上海交通大学四川研究院);Sun Yat-Sen University(中山大学);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司)
In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload masses (several hundred kg in total) and their thermal isolation, a cooling time of several months is required. Our calculation shows that a high-emissivity coating (e.g. a diamond-like carbon (DLC) coating) can reduce the cooling time effectively by enhancing radiation heat transfer. Here, we have experimentally verified the effect of the DLC coating on th…
PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large detector. In this paper, the results on the commission of the cryogenics and gas handling system are reported. The maximum cooling power of ~ 580 W at 178 K with three cooperating coldheads has been achieved. The filling rate with an assisted liquid nitrogen cooling can reach ~ 700 kg/day. The average rate of recuperation by liquid nitrogen is around 440 kg/d…
We present a cryogenic setup where an optical Fabry-Perot resonator is coupled to a single-mode optical fiber with coupling efficiency above 90% at mK temperatures without realignment during cooling down. The setup is prealigned at room temperature to compensate for the thermal contraction and change of the refractive index of the optical components during cooling down. The high coupling efficiency is achieved by keeping the setup rotation-symmetric around the optical axis. The majority of the setup components are made of Invar (FeNi36) which minimizes the thermal contraction. High coupling ef…
We present two simple cryogenic RF ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 hours. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The vibration amplitude of the closed cycled cryostat was found to be below 106 nm. We evaluated the systems by loading surface-electrode ion traps with $^{88}$Sr$^+$ ions using laser ablation, which is…
KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We performed vibration analysis of the cooling system at cryogenic temperature to study its impact on detector sensitivity. Our measurement show shield vibration below 1 Hz is not impacted by cryocooler operation or structural resonances and follows ground motion. The noise floor of the shield in 1-100 Hz was observed to be 2-3 order of magnitude larger than seis…
We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and high-pressure (1.7 MPa) helium gas and electricity to the cryocooler. The operation of the cryocooler and other instruments requires the development of interface components between the ground and rotating table. A combination of access holes at the center of the table and two rotary joints allows simultaneous circulation of electricity and helium gas. The deve…
Cryogenic cooling of the test masses of interferometric gravitational wave detectors is a promising way to reduce thermal noise. However, cryogenic cooling limits the incident power to the test masses, which limits the freedom of shaping the quantum noise. Cryogenic cooling also requires short and thick suspension fibers to extract heat, which could result in the worsening of thermal noise. Therefore, careful tuning of multiple parameters is necessary in designing the sensitivity of cryogenic gravitational wave detectors. Here, we propose the use of particle swarm optimization to optimize the …
The fundamental limits of the microwave noise performance of high electron mobility transistors (HEMTs) are of scientific and practical interest for applications in radio astronomy and quantum computing. Self-heating at cryogenic temperatures has been reported to be a limiting mechanism for the noise, but cryogenic cooling strategies to mitigate it, for instance using liquid cryogens, have not been evaluated. Here, we report microwave noise measurements of a packaged two-stage HEMT amplifier immersed in normal and superfluid $^4$He baths and in vacuum from 1.6 - 80 K. We find that these liquid…
Panda-X is a liquid xenon dual-phase detector for the Dark Matter Search. The first modestly-sized module will soon be installed in the China JinPing Deep Underground Laboratory in Sichuan province, P.R. China. The cryogenics system is designed to handle much larger detectors, even the final version in the ton scale. Special attention has been paid to the reliability, serviceability, and adaptability to the requirements of a growing experiment. The system is cooled by a single Iwatani PC150 Pulse Tube Refrigerator. After subtracting all thermal losses, the remaining cooling power is still 82W.…
In the described device, the thermal emissivity or absorptivity of the sample is measured by substitution of the radiative heat flow between two parallel surfaces by thermal output of a heater. Fast measurements of the mutual emissivity for the range of the temperature of the radiating surface 25 K-150 K are possible. The absorbing surface has a temperature between 5 K and 10 K when LHe is used as cryoliquid. The desired measurement sensitivity is 1 mK for temperature and 0.1 μW for heat power, respectively. The diameter of the whole device is 50 mm and so it is possible to use a commercial de…
The throttling refrigeration system for high cooling power recovery of the PandaX-xT cryogenic distillation system for radon removal
SJTU Paris Elite Institute of Technology, Shanghai Jiao Tong University(上海交通大学巴黎卓越工程师学院);New Cornerstone Science Laboratory, Tsung-Dao Lee Institute, Shanghai Jiao Tong University(新Cornerstone科学实验室,汤川秀树研究所,上海交通大学);School of Physics and Astronomy, Shanghai Jiao Tong University(上海交通大学物理与天文学院);Shanghai Jiao Tong University Sichuan Research Institute(上海交通大学四川研究院);Jinping Deep Underground Frontier Science and Dark Matter Key Laboratory of Sichuan Province(四川省锦屏深地下前沿科学与暗物质重点实验室);Vacree Technologies Co., Ltd.(沃瑞科技有限公司);School of Chemical Engineering, Zhengzhou University(郑州大学化学工程与应用学院);School of Physics, Sun Yat-Sen University(中山大学物理学院);Department of Physics, University of Maryland, College Park(马里兰大学帕克分校物理系);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司)
Two cryogenic bath-type heat exchangers for ultra-pure noble gas applications were developed with particular emphasis on noble gas liquefaction in cryogenic distillation systems. The main objective was to construct heat exchangers for xenon from materials that do not emanate radon and that fulfill ultra-high vacuum standards. Therefore, only high-quality copper and stainless steel materials were used. Especially, large-area oxygen-free copper fins with high conductivity in a new design ensure efficient heat transfer. One bath-type Xe-Xe heat exchanger was designed with a diameter of 50 cm to a…
The paper describes a radio frequency (RF) spectrometer for 14N nuclear quadrupole resonance (NQR) spectroscopy that uses a detector coil cooled to 77 K to maximize measurement sensitivity. The design uses a minimally-intrusive network of active duplexers and mechanical contact switches to realize a digitally reconfigurable series/parallel coil tuning network that allows transmit- and receive-mode performance to be independently optimized. The design is battery-powered and includes a mixed-signal embedded system to monitor and control secondary processes, thus enabling autonomous operation. Te…
We describe the design, commissioning and operation of an ultra-low-vibration closed-cycle cryogenic ion trap apparatus. One hundred lines for low-frequency signals and eight microwave / radio frequency coaxial feed lines offer the possibility of implementing a small-scale ion-trap quantum processor or simulator. With all supply cables attached, more than 1.3 W of cooling power at 5 K is still available for absorbing energy from electrical pulses introduced to control ions. The trap itself is isolated from vibrations induced by the cold head using a helium exchange gas interface. The performan…
The frontiers of quantum electronics have been linked to the discovery of new refrigeration methods since the discovery of superconductivity at a temperature around $4\,$K, enabled by the liquefaction of helium. Since then, the advances in cryogenics led to discoveries such as the quantum Hall effect and new technologies like superconducting and semiconductor quantum bits. Presently, nanoelectronic devices typically reach electron temperatures around $10\,$mK to $100\,$mK by commercially available dilution refrigerators. However, cooling electrons via the encompassing lattice vibrations, or ph…