The Cryogenic Sapphire Oscillator is today recognized for its unprecedented frequency stability, mainly coming from the exceptional physical properties of its resonator made in a high quality sapphire crystal. With these instruments, the fractional frequency measurement resolution, currently of the order of 1e-16, is such that it is possible to detect very small phenomena like residual resonator environmental sensitivities. Thus, we highlighted an unexpected magnetic sensitivity of the Cryogenic Sapphire Oscillator (CSO) at low magnetic field. The fractional frequency sensitivity has been preliminary evaluated to 1e-13/Gauss, making this phenomenon a potential cause of frequency stability limitation. In this paper we report the experimental data related to the magnetic sensitivity of the quasi-transverse magnetic Whispering Gallery (WGH) modes excited in sapphire crystals differing from their paramagnetic contaminants concentration. The magnetic behavior of the WGH modes does not follow the expected theory combining the Curie law and the Zeeman effect affecting the Electron Spin Resonance of the paramagnetic ions present in the crystal.
We present the characterisation of three Cryogenic Sapphire Oscillators using the three-corner-hat method. Easily implemented with commercial components and instruments, this method reveals itself very useful to analyse the frequency stability limitations of these state-of-the-art ultra-stable oscillators. The best unit presents a fractional frequency stability better than 5e-16 at 1 s and below 2e-16 for integration times less than 5,000s.
We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a shift in the resonance frequency. We measure a modulation and temperature independent radiation pressure induced power to frequency sensitivity of -0.15 Hz/mW and find that this is the primary factor li…
We report on the evaluation of microwave frequency synthesis using two cryogenic sapphire oscillators developed at the University of Western Australia. A down converter is used to make comparisons between microwave clocks at different frequencies, where the synthesized signal has a stability not significantly different from the reference oscillator. By combining the CSO with a H-maser, a reference source of arbitrary frequency at X-band can be synthesized with a fractional frequency stability of sub-$4 \times 10^{-15}$ for integration times between 1 s and 10,000 s.
We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.
A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their combined fractional frequency instability is $σ_y = 1.4 \times 10^{-15}τ^{-1/2}$ for integration times $1 < τ< 10$ s, dominated by white frequency noise. The minimum $σ_y = 5.3 \times 10^{-16}$ for the two oscillators was reached at $τ= 20$ s. Assuming equal contributions from both CSOs, the single oscillator phase noise $S_ϕ \approx -96 \; dB \; rad^2/Hz$ at…
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryogenic temperature. On basis of these measurements, we estimated the shot noise sensitivity of the interferometer with thermal lensing by using a wave-front tracing simulation. We found that thermal lensi…
The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1 and 10,000 s, with a drift <1e-14 in one day.The oscillator is based on a sapphire monocrystal resonating at 10 GHz in a whispering-gallery mode, cooled at 6 K for highest Q-factor and zero thermal coefficient. We report on the progress accomplished implementing eleven CSOs in about 10 years since the first sample delivered to the ESA station in Argentina. …
To create a stable signal from a cryogenic sapphire maser frequency standard, the frequency-temperature dependence of the supporting Whispering Gallery mode must be annulled. We report the ability to control this dependence by manipulating the paramagnetic susceptibility of Fe3+ ions in the sapphire lattice. We show that the maser signal depends on other Whispering Gallery modes tuned to the pump signal near 31 GHz, and the annulment point can be controlled to exist between 5 to 10 K depending on the Fe3+ ion concentration and the frequency of the pump. This level of control has not been achie…
Here, we study the paramagnetic ions behavior in presence of a strong microwave electromagnetic field sustained inside a cryogenic sapphire whispering gallery mode resonator. The high frequency measurement resolution that can be now achieved by comparing two CSOs permit for the first time to observe clearly the non-linearity of the resonator power sensitivity. These observations that in turn allow us to optimize the CSO operation, are well explained by the Electron Spin Resonance (ESR) saturation of the paramagnetic impurities contained in the sapphire crystal.
A low maintenance long-term operational cryogenic sapphire oscillator has been implemented at 11.2 GHz using an ultra-low-vibration cryostat and pulse-tube cryocooler. It is currently the world's most stable microwave oscillator employing a cryocooler. Its performance is explained in terms of temperature and frequency stability. The phase noise and the Allan deviation of frequency fluctuations have been evaluated by comparing it to an ultra-stable liquid-helium cooled cryogenic sapphire oscillator in the same laboratory. Assuming both contribute equally, the Allan deviation evaluated for the c…
This article shows the first measurement of three 100 MHz signals exhibiting fluctuations from 2E-16 to parts in 1E-15 for integration time tau between 1 s and 1 day. Such stable signals are provided by three Cryogenic Sapphire Oscillators (CSOs) operating at about 10 GHz, also delivering the 100 MHz output via a dedicated synthesizer. The measurement is made possible by a 6-channel Tracking DDS (TDDS) and the two-sample covariance tool, used to estimate the Allan variance. The use of two TDDS channels per CSO enables high rejection of the instrument background noise. The covariance outperform…
We present the characterization of 8-12 GHz whispering gallery mode resonators machined in high-quality sapphire crystals elaborated with different growth techniques. These microwave resonators are intended to constitute the reference frequency of ultra-stable Cryogenic Sapphire Oscillators. We conducted systematic tests near 4 K on these crystals to determine the unloaded Q-factor and the turnover temperature for whispering gallery modes in the 8-12 GHz frequency range. These characterizations show that high quality sapphire crystals elaborated with the Heat Exchange or the Kyropoulos growth …
We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.
The third-generation gravitational wave detectors are under development by operating the detector in cryogenic temperature to reduce the thermal noise. Silicon and sapphire are promising candidate materials for the test masses and suspension elements due to their remarkable mechanical and thermal properties at cryogenic temperature. Here we present the performances of the cryogenic thermal cycling and strength testing on hydroxide catalysis bonding between sapphire and silicon. Our results suggest that although these two materials have very different coefficients of thermal expansion, but if t…
Two nominally identical ultra-stable cryogenic microwave oscillators are compared. Each incorporates a dielectric-sapphire resonator cooled to near 6 K in an ultra-low vibration cryostat using a low-vibration pulse-tube cryocooler. The phase noise for a single oscillator is measured at -105 dBc/Hz at 1 Hz offset on the 11.2 GHz carrier. The oscillator fractional frequency stability is characterized in terms of Allan deviation by 5.3 x 10^-16 tau^-1/2 + 9 x 10^-17 for integration times 0.1 s < tau < 1000 s and is limited by a flicker frequency noise floor below 1 x 10^-16. This result is better…
The phase noise and frequency stability measurements of 1 GHz, 100 MHz, and 10 MHz signals are presented which have been synthesized from microwave cryogenic sapphire oscillators using ultra-low-vibration pulse-tube cryocooler technology. We present the measured data using independent cryogenic oscillators for the 100 MHz and 10 MHz synthesized signals, whereas previously we only estimated the expected results based on residual phase noise measurements, when only one cryogenic oscillator was available. In addition we present the design of a 1 GHz synthesizer using a Crystek voltage controlled …
We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters from the photon sector of the standard model extension. Thus, we are able to place independent limits on all eight $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters. Our results represents up to a factor of 10 improvement over previous non rotati…
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other appli…
The fundamental limits of the microwave noise performance of high electron mobility transistors (HEMTs) are of scientific and practical interest for applications in radio astronomy and quantum computing. Self-heating at cryogenic temperatures has been reported to be a limiting mechanism for the noise, but cryogenic cooling strategies to mitigate it, for instance using liquid cryogens, have not been evaluated. Here, we report microwave noise measurements of a packaged two-stage HEMT amplifier immersed in normal and superfluid $^4$He baths and in vacuum from 1.6 - 80 K. We find that these liquid…
The careful filtering of microwave electromagnetic radiation is critical for controlling the electromagnetic environment for experiments in solid-state quantum information processing and quantum metrology at millikelvin temperatures. We describe the design and fabrication of a coaxial filter assembly and demonstrate that its performance is in excellent agreement with theoretical modelling. We further perform an indicative test of the operation of the filters by making current-voltage measurements of small, underdamped Josephson junctions at 15 mK.
Yttrium Vanadate (YVO4) is a birefringent crystal material used in optical isolators and circulators with potentials for application in cryogenic microwave devices. As microwave properties of the YVO4 are not known, we measured the complex permittivity at the frequency of 25 GHz, using the Hakki-Coleman dielectric resonator technique in the temperature range from 13 K to 80 K. The real part of relative permittivity of YVO4 turned out to be similar to that of Sapphire - one of popular dielectric materials, used at microwave frequencies. The measured loss tangent tang δ of the YVO4 was of the or…
We present the characterization of commercial tunnel diode low-level microwave power detectors at room and cryogenic temperatures. The sensitivity as well as the output voltage noise of the tunnel diodes are measured as functions of the applied microwave power, the signal frequency being 10 GHz. We highlight strong variations of the diode characteristics when the applied microwave power is higher than few microwatt. For a diode operating at ${4}$ K, the differential gain increases from ${1,000}$ V/W to about ${4,500}$ V/W when the power passes from ${-30}$ dBm to ${-20}$ dBm. The diode present…
Construction of a large-scale cryogenic gravitational-wave telescope KAGRA has been completed and the four sapphire test masses have been installed in cryostat vacuum chambers. It recently turned out that a sapphire substrate used for one of the input test masses shows a characteristic strcuture in its transmission map due to non-uniformity of the crystal. We performed an interferometer simulation to see the influence of the non-uniformity using measured transmission/reflection maps.
Amplification is usually necessary when measuring the frequency instability of microwave signals. In this work, we develop a flicker noise free frequency measurement system based on a common or shared amplifier. First, we show that correlated flicker phase noise can be cancelled in such a system. Then we compare the new system with the conventional by simultaneously measuring the beat frequency from two cryogenic sapphire oscillators with parts in 10^15 fractional frequency instability. We determine for low power, below -80 dBm, the measurements were not limited by correlated noise processes b…
In recent years there has been considerable interest in exploiting the temperature dependence of sapphire whispering gallery mode frequency to develop a mechanically stable, high accuracy temperature sensor. Disk-resonator-based devices have been demonstrated to measure temperature with .01 K or better accuracy in the temperature range of 273 K to 373 K. Here we have utilized automated data acquisition and processing to rapidly evaluate a mechanically-stabilized sapphire whispering gallery mode resonator based on a hollow cylinder configuration.
This article reports the design, the breadboarding and the validation of an ultra-stable Cryogenic Sapphire Oscillator operated in an autonomous cryocooler. The objective of this project was to demonstrate the feasibility of a frequency stability of 3x10-15 between 1 s and 1,000 s for the European Space Agency deep space stations. This represents the lowest fractional frequency instability ever achieved with cryocoolers. The preliminary results presented in this paper validate the design we adopted for the sapphire resonator, the cold source and the oscillator loop.
We propose a new type of cryogenic current amplifiers, in which low-frequency power spectrum of current can be measured through a measurement of microwave response of a superconducting resonant circuit shunted by a series array of Josephson junctions. From numerical analysis on the equivalent circuit, the numerical value of the input-referred current noise of the proposed amplifier is found to be two orders of magnitude lower than the noise floor measured with the conventional cryogenic current amplifiers based on high-electron-mobility transistors or superconducting quantum interference devic…
The thermal lensing effects in the lasing crystal appear to be dominant when the pump laser focused on the lasing crystal which causes the local heating effect. The spatial refractive index variations observed if the crystal has non-uniform temperature distribution. In the present study, the demonstration of thermal lensing effect of Brewster-cut Ti: Sapphire crystal carried out when pumped by 25 ps pulses at 80 MHz repetition rate with 532 nm central wavelength, while the average pump power controlled by the attenuator. The thermal lensing effects measured first at the ~293 K temperature and …
We present the design and first measurement results for an ultra-stable cryogenically cooled optical sapphire resonator system with a potential relative frequency stability better than 3x10^-17. This level of oscillator stability allows for more precise tests of Einstein's theories of relativity and thus could help to find first hints of "new physics". We will give some details on a projected experiment to test Lorentz invariance that will utilize these cavities.
The hidden sector photon is a weakly interacting hypothetical particle with sub-eV mass that kinetically mixes with the photon. We describe a microwave frequency light shining through a wall experiment where a cryogenic resonant microwave cavity is used to try and detect photons that have passed through an impenetrable barrier, a process only possible via mixing with hidden sector photons. For a hidden sector photon mass of 53 $μ$eV we limit the hidden photon kinetic mixing parameter $χ< 1.7\times10^{-7}$, which is an order of magnitude lower than previous bounds derived from cavity experiment…
We present a Michelson-Morley type experiment for testing the isotropy of the speed of light in vacuum and matter. The experiment compares the resonance frequency of an actively rotated monolithic optical cryogenic sapphire resonator against the resonance frequency of a stationary evacuated optical cavity made of ultra-low-expansion glass. The results yield an upper limit for the anisotropy of the speed of light in matter (sapphire) of Delta(c)/c < 1 x 10^-16, limited by the frequency stability of the sapphire resonator.
We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected using chirped pulse microwave spectroscopy. Here we demonstrate three significant improvements to the apparatus relative to an earlier version: (1) extension of its operating range by more than a factor of two, from 12-18 GHz to 12-26 GHz, which allows a much wider range of species to be characterized; (2) improved detection sensitivity owing to use of cryogenic…
We introduce an improved microwave calibration method for use in a cryogenic environment, based on a traditional three-standard calibration, the Thru-Reflect-Line (TRL) calibration. The modified calibration method takes advantage of additional information from multiple measurements of an ensemble of realizations of a superconducting resonator, as a new pseudo-Open standard, to correct errors in the TRL calibration. We also demonstrate an experimental realization of this in-situ broadband cryogenic calibration system utilizing cryogenic switches. All calibration measurements are done in the sam…
Simple broadband microwave interconnects are needed for increasing the size of focal plane heterodyne radiometer arrays. We have measured loss and cross-talk for arrays of microstrip transmission lines in flex circuit technology at 297 and 77 K, finding good performance to at least 20 GHz. The dielectric constant of Kapton substrates changes very little from 297 to 77 K, and the electrical loss drops. The small cross-sectional area of metal in a printed circuit structure yields overall thermal conductivities similar to stainless steel coaxial cable. Operationally, the main performance tradeoff…
The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of \bigO(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of \bigO{(1,000)}, microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that co…
A wide variety of applications of microwave cavities, such as measurement and control of superconducting qubits, magnonic resonators, and phase noise filters, would be well served by having a highly tunable microwave resonance. Often this tunability is desired in situ at low temperatures, where one can take advantage of superconducting cavities. To date, such cryogenic tuning while maintaining a high quality factor has been limited to $\sim500$ MHz. Here we demonstrate a three-dimensional superconducting microwave cavity that shares one wall with a pressurized volume of helium. Upon pressuriza…
The ability to achieve strong-coupling has made cavity-magnon systems an exciting platform for the development of hybrid quantum systems and the investigation of fundamental problems in physics. Unfortunately, current experimental realizations are constrained to operate at a single frequency, defined by the geometry of the microwave cavity. In this article we realize a highly-tunable, cryogenic, microwave cavity strongly coupled to magnetic spins. The cavity can be tuned in situ by up to 1.5 GHz, approximately 15% of its original 10 GHz resonance frequency. Moreover, this system remains within…
We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range of large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4-nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured…
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of $2.2 \times 10^{-19}\,\textrm{m}…
Exploring Low Energy Excess in MINER with sapphire detectors using Convolutional Variational Autoencoder (CVAE)
National Institute of Science Education and Research(印度科学教育研究所);Homi Bhabha National Institute(霍米·巴巴国立研究所);Texas A&M University(德克萨斯农工大学);Sam Houston State University(山姆休斯顿州立大学);SNOLAB(SNOLAB实验室)
This article reports on the long-term frequency stabilty characterisation of a new type of cryogenic sapphire oscillator using an autonomous pulse-tube cryocooler as its cold source. This new design enables a relative frequency stability of better than 4.5e-15 over one day of integration. This represents to our knowledge the best long-term frequency stability ever obtained with a signal source based on a macroscopic resonator.
We present first results from a number of experiments conducted on a 0.53 kg cylindrical dumbbell-shaped sapphire crystal. This is the first reported optomechanical experiment of this nature utilising a novel modification to the typical cylindrical architecture. Mechanical motion of the crystal structure alters the dimensions of the crystal, and the induced strain changes the permittivity. These two effects result in parametric frequency modulation of resonant microwave whispering gallery modes that are simultaneously excited within the crystal. A novel low-noise microwave readout system is im…
Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator
Politecnico di Torino(都灵理工大学);University of Palermo(巴勒莫大学);Istituto Nazionale di Ricerca Metrologica (INRiM)(意大利国家计量研究所);Università degli Studi di Pisa(比萨大学)
We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the sensitivity (50-75~$μ$K/$\sqrt{\mathrm{Hz}}$) is relatively uniform across this range. The miniature footprint that conveniently attaches to the feedline of a cryogenic microwave device facilitates the measurement of on-chip device temperature and requires no additional thermometry wiring or readout electronics. We demonstrate the practical use of these TLS t…
Large arrays of cryogenic detectors, including transition-edge sensors (TESs) or magnetic micro-calorimeters (MMCs), are needed for future experiments across a wide range of applications. Complexities in integration and cryogenic wiring have driven efforts to develop cryogenic readout technologies with large multiplexing factors while maintaining minimal readout noise. One such example is the microwave SQUID multiplexer ($μ$mux), which couples an incoming TES or magnetic calorimeter signal to a unique GHz-frequency resonance that is modulated in frequency. Here, we present a hybrid scheme comb…
We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission coefficient of the cryogenic resonator we computed its noise suppression function. This was done via Monte-Carlo simulations some details of which are discussed in this Letter. Next, we measured technical fluctuations of a signal incident on the cryogenic resonator. Having processed these data with the previously computed noise filtering "template" we inferred noise s…
KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We performed vibration analysis of the cooling system at cryogenic temperature to study its impact on detector sensitivity. Our measurement show shield vibration below 1 Hz is not impacted by cryocooler operation or structural resonances and follows ground motion. The noise floor of the shield in 1-100 Hz was observed to be 2-3 order of magnitude larger than seis…