Cryogenic measurement of the optical absorption coefficient in sapphire crystals at 1.064(micro)m for the Large-scale Cryogenic Gravitational wave Telescope
We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryogenic temperature. On basis of these measurements, we estimated the shot noise sensitivity of the interferometer with thermal lensing by using a wave-front tracing simulation. We found that thermal lensi…
We present the characterisation of three Cryogenic Sapphire Oscillators using the three-corner-hat method. Easily implemented with commercial components and instruments, this method reveals itself very useful to analyse the frequency stability limitations of these state-of-the-art ultra-stable oscillators. The best unit presents a fractional frequency stability better than 5e-16 at 1 s and below 2e-16 for integration times less than 5,000s.
We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.
We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a shift in the resonance frequency. We measure a modulation and temperature independent radiation pressure induced power to frequency sensitivity of -0.15 Hz/mW and find that this is the primary factor li…
The Cryogenic Sapphire Oscillator is today recognized for its unprecedented frequency stability, mainly coming from the exceptional physical properties of its resonator made in a high quality sapphire crystal. With these instruments, the fractional frequency measurement resolution, currently of the order of 1e-16, is such that it is possible to detect very small phenomena like residual resonator environmental sensitivities. Thus, we highlighted an unexpected magnetic sensitivity of the Cryogenic Sapphire Oscillator (CSO) at low magnetic field. The fractional frequency sensitivity has been prel…
To create a stable signal from a cryogenic sapphire maser frequency standard, the frequency-temperature dependence of the supporting Whispering Gallery mode must be annulled. We report the ability to control this dependence by manipulating the paramagnetic susceptibility of Fe3+ ions in the sapphire lattice. We show that the maser signal depends on other Whispering Gallery modes tuned to the pump signal near 31 GHz, and the annulment point can be controlled to exist between 5 to 10 K depending on the Fe3+ ion concentration and the frequency of the pump. This level of control has not been achie…
We report on the evaluation of microwave frequency synthesis using two cryogenic sapphire oscillators developed at the University of Western Australia. A down converter is used to make comparisons between microwave clocks at different frequencies, where the synthesized signal has a stability not significantly different from the reference oscillator. By combining the CSO with a H-maser, a reference source of arbitrary frequency at X-band can be synthesized with a fractional frequency stability of sub-$4 \times 10^{-15}$ for integration times between 1 s and 10,000 s.
Here, we study the paramagnetic ions behavior in presence of a strong microwave electromagnetic field sustained inside a cryogenic sapphire whispering gallery mode resonator. The high frequency measurement resolution that can be now achieved by comparing two CSOs permit for the first time to observe clearly the non-linearity of the resonator power sensitivity. These observations that in turn allow us to optimize the CSO operation, are well explained by the Electron Spin Resonance (ESR) saturation of the paramagnetic impurities contained in the sapphire crystal.
A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their combined fractional frequency instability is $σ_y = 1.4 \times 10^{-15}τ^{-1/2}$ for integration times $1 < τ< 10$ s, dominated by white frequency noise. The minimum $σ_y = 5.3 \times 10^{-16}$ for the two oscillators was reached at $τ= 20$ s. Assuming equal contributions from both CSOs, the single oscillator phase noise $S_ϕ \approx -96 \; dB \; rad^2/Hz$ at…
The third-generation gravitational wave detectors are under development by operating the detector in cryogenic temperature to reduce the thermal noise. Silicon and sapphire are promising candidate materials for the test masses and suspension elements due to their remarkable mechanical and thermal properties at cryogenic temperature. Here we present the performances of the cryogenic thermal cycling and strength testing on hydroxide catalysis bonding between sapphire and silicon. Our results suggest that although these two materials have very different coefficients of thermal expansion, but if t…
The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1 and 10,000 s, with a drift <1e-14 in one day.The oscillator is based on a sapphire monocrystal resonating at 10 GHz in a whispering-gallery mode, cooled at 6 K for highest Q-factor and zero thermal coefficient. We report on the progress accomplished implementing eleven CSOs in about 10 years since the first sample delivered to the ESA station in Argentina. …
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other appli…
We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters from the photon sector of the standard model extension. Thus, we are able to place independent limits on all eight $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters. Our results represents up to a factor of 10 improvement over previous non rotati…
A low maintenance long-term operational cryogenic sapphire oscillator has been implemented at 11.2 GHz using an ultra-low-vibration cryostat and pulse-tube cryocooler. It is currently the world's most stable microwave oscillator employing a cryocooler. Its performance is explained in terms of temperature and frequency stability. The phase noise and the Allan deviation of frequency fluctuations have been evaluated by comparing it to an ultra-stable liquid-helium cooled cryogenic sapphire oscillator in the same laboratory. Assuming both contribute equally, the Allan deviation evaluated for the c…
This article shows the first measurement of three 100 MHz signals exhibiting fluctuations from 2E-16 to parts in 1E-15 for integration time tau between 1 s and 1 day. Such stable signals are provided by three Cryogenic Sapphire Oscillators (CSOs) operating at about 10 GHz, also delivering the 100 MHz output via a dedicated synthesizer. The measurement is made possible by a 6-channel Tracking DDS (TDDS) and the two-sample covariance tool, used to estimate the Allan variance. The use of two TDDS channels per CSO enables high rejection of the instrument background noise. The covariance outperform…
Construction of a large-scale cryogenic gravitational-wave telescope KAGRA has been completed and the four sapphire test masses have been installed in cryostat vacuum chambers. It recently turned out that a sapphire substrate used for one of the input test masses shows a characteristic strcuture in its transmission map due to non-uniformity of the crystal. We performed an interferometer simulation to see the influence of the non-uniformity using measured transmission/reflection maps.
The phase noise and frequency stability measurements of 1 GHz, 100 MHz, and 10 MHz signals are presented which have been synthesized from microwave cryogenic sapphire oscillators using ultra-low-vibration pulse-tube cryocooler technology. We present the measured data using independent cryogenic oscillators for the 100 MHz and 10 MHz synthesized signals, whereas previously we only estimated the expected results based on residual phase noise measurements, when only one cryogenic oscillator was available. In addition we present the design of a 1 GHz synthesizer using a Crystek voltage controlled …
We present the characterization of 8-12 GHz whispering gallery mode resonators machined in high-quality sapphire crystals elaborated with different growth techniques. These microwave resonators are intended to constitute the reference frequency of ultra-stable Cryogenic Sapphire Oscillators. We conducted systematic tests near 4 K on these crystals to determine the unloaded Q-factor and the turnover temperature for whispering gallery modes in the 8-12 GHz frequency range. These characterizations show that high quality sapphire crystals elaborated with the Heat Exchange or the Kyropoulos growth …
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of $2.2 \times 10^{-19}\,\textrm{m}…
We present the design and first measurement results for an ultra-stable cryogenically cooled optical sapphire resonator system with a potential relative frequency stability better than 3x10^-17. This level of oscillator stability allows for more precise tests of Einstein's theories of relativity and thus could help to find first hints of "new physics". We will give some details on a projected experiment to test Lorentz invariance that will utilize these cavities.
The thermal lensing effects in the lasing crystal appear to be dominant when the pump laser focused on the lasing crystal which causes the local heating effect. The spatial refractive index variations observed if the crystal has non-uniform temperature distribution. In the present study, the demonstration of thermal lensing effect of Brewster-cut Ti: Sapphire crystal carried out when pumped by 25 ps pulses at 80 MHz repetition rate with 532 nm central wavelength, while the average pump power controlled by the attenuator. The thermal lensing effects measured first at the ~293 K temperature and …
We present a Michelson-Morley type experiment for testing the isotropy of the speed of light in vacuum and matter. The experiment compares the resonance frequency of an actively rotated monolithic optical cryogenic sapphire resonator against the resonance frequency of a stationary evacuated optical cavity made of ultra-low-expansion glass. The results yield an upper limit for the anisotropy of the speed of light in matter (sapphire) of Delta(c)/c < 1 x 10^-16, limited by the frequency stability of the sapphire resonator.
A number of critical active and passive components of optical links have been tested at 77 K or lower temperatures, demonstrating potential development of optical links operating inside the liquid argon time projection chamber (LArTPC) detector cryostat. A ring oscillator, individual MOSFETs, and a high speed 16:1 serializer fabricated in a commercial 0.25-um silicon-on-sapphire CMOS technology continued to function from room temperature to 4.2 K, 15 K, and 77 K respectively. Three types of laser diodes lase from room temperature to 77 K. Optical fibers and optical connectors exhibited minute …
Exploring Low Energy Excess in MINER with sapphire detectors using Convolutional Variational Autoencoder (CVAE)
National Institute of Science Education and Research(印度科学教育研究所);Homi Bhabha National Institute(霍米·巴巴国立研究所);Texas A&M University(德克萨斯农工大学);Sam Houston State University(山姆休斯顿州立大学);SNOLAB(SNOLAB实验室)
The polarization modulator unit for the low-frequency telescope in LiteBIRD employs an achromatic half-wave plate (AHWP). It consists of five layers of a-cut sapphire plate, which are stacked based on a Pancharatnam recipe. In this way, the retardance of the AHWP is a half-wave over a bandwidth of 34-161 GHz. The diameter of a single sapphire plate is about 500 mm and the thickness is 5 mm. When a large diameter AHWP is used for a space mission, it is important for the AHWP to survive launch vibration. A preliminary study indicates that the five-layer stacked HWP has a risk of breakage at the …
We present first results from a number of experiments conducted on a 0.53 kg cylindrical dumbbell-shaped sapphire crystal. This is the first reported optomechanical experiment of this nature utilising a novel modification to the typical cylindrical architecture. Mechanical motion of the crystal structure alters the dimensions of the crystal, and the induced strain changes the permittivity. These two effects result in parametric frequency modulation of resonant microwave whispering gallery modes that are simultaneously excited within the crystal. A novel low-noise microwave readout system is im…
In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced to fracture events in the sapphire due to the very tight clamping of the detectors. During extensive runs the energy and time of each event was recorded, providing large data sets for such phenomena. We believe this is the first time the energy release in fracture has been directly and accurately measured on a microscopic event-by-event basis. The energy threshold corresponds to the breaking of onl…
Resonance modes in single crystal sapphire ($α$-Al$_2$O$_3$) exhibit extremely high electrical and mechanical Q-factors ($\approx 10^9$ at 4K), which are important characteristics for electromechanical experiments at the quantum limit. We report the first cooldown of a bulk sapphire sample below superfluid liquid helium temperature (1.6K) to as low as 25mK. The electromagnetic properties were characterised at microwave frequencies, and we report the first observation of electromagnetically induced thermal bistability in whispering gallery modes due to the material $T^3$ dependence on thermal c…
We introduce an improved microwave calibration method for use in a cryogenic environment, based on a traditional three-standard calibration, the Thru-Reflect-Line (TRL) calibration. The modified calibration method takes advantage of additional information from multiple measurements of an ensemble of realizations of a superconducting resonator, as a new pseudo-Open standard, to correct errors in the TRL calibration. We also demonstrate an experimental realization of this in-situ broadband cryogenic calibration system utilizing cryogenic switches. All calibration measurements are done in the sam…
We developed a simple, flexible, low-cost, and computer-controlled cryogenic temperature measurement system for undergraduate instructional laboratories. An Arduino microcontroller board measures the voltage across a silicon diode to calculate its temperature. Resistors and a voltage regulator provide constant current into the silicon diode. We present a graphical user interface based on the open-source Processing language. The cost of the complete temperature measurement system is thus only a small fraction of any highly-developed commercial system. Our performance test shows that the system …
We describe a two-color pump-probe scanning magneto-optical Kerr effect (MOKE) microscope which we have developed to investigate electron spin phenomena in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution. The key innovation of our microscope is the usage of an ultrafast `white light' supercontinuum fiber-laser source which provides access to the whole visible and near-infrared spectral range. Our Kerr microscope allows for the independent selection of the excitation and detection energy while avoiding the necessity to synchronize the pulse trains…
Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator
Politecnico di Torino(都灵理工大学);University of Palermo(巴勒莫大学);Istituto Nazionale di Ricerca Metrologica (INRiM)(意大利国家计量研究所);Università degli Studi di Pisa(比萨大学)