The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1 and 10,000 s, with a drift <1e-14 in one day.The oscillator is based on a sapphire monocrystal resonating at 10 GHz in a whispering-gallery mode, cooled at 6 K for highest Q-factor and zero thermal coefficient. We report on the progress accomplished implementing eleven CSOs in about 10 years since the first sample delivered to the ESA station in Argentina.
Short-term stability is improved by a factor of 3-10, depending on the integration time, and the refrigerator's electric power is reduced to 3 kW. Frequency stability and overall performances are reproducible, with unattended operation between scheduled maintenance every two years. The CSO is suitable to scientific applications requiring extreme frequency stability with reliable long-term operation. For example, the flywheel for primary frequency standards, the ground segment of GNSS, astrometry, VLBI, and radio astronomy stations.
Cryogenic measurement of the optical absorption coefficient in sapphire crystals at 1.064(micro)m for the Large-scale Cryogenic Gravitational wave Telescope
Ultra-low-phase-noise cryocooled microwave dielectric-sapphire-resonator oscillators with 1 x 10^-16 frequency instability
两个名义上相同的超稳定低温微波振荡器进行了比较。每一个都采用了一个介质蓝宝石谐振器冷却到近6 K的超低振动低温恒温器使用低振动脉冲管制冷机。在11.2 GHz载波上,单个振荡器的相位噪声在1 Hz偏移处测量为-105 dBc/Hz。振荡器的分数频率稳定度的特征在于,在积分时间为0.1 s < tau < 1000 s的情况下,阿伦偏差为5.3 x 10^-16 tau^-1/2 + 9 x 10^-17,并且受到低于1 x 10^-16的闪烁频率噪声基底的限制。这一结果优于任何其他微波源,甚至是那些从光梳锁相到室温超稳光腔产生的微波源。
Electromagnetic cavity tests of Lorentz invariance on Earth and in space
本文提出了一个迈克尔逊-莫雷型实验,用来测量真空和物质中光速的各向同性。该实验比较了主动旋转的单片光学低温蓝宝石谐振器的谐振频率与由超低膨胀玻璃制成的静止真空光学腔的谐振频率。结果得出物质(蓝宝石)中光速各向异性的上限为Delta(c)/c < 1 x 10^-16,这受到蓝宝石谐振器频率稳定性的限制。
CE$ν$NS Search with Cryogenic Sapphire Detectors at MINER: Results from the TRIGA reactor data and Future Sensitivity at HFIR
National Institute of Science Education and Research(印度国家科学教育与研究机构);Sam Houston State University(山姆休斯敦州立大学);University of Toronto(多伦多大学);SNOLAB(斯诺实验室);The University of Texas at Austin(得克萨斯大学奥斯汀分校);University of Minnesota(明尼苏达大学);ARC Centre of Excellence for Dark Matter Particle Physics, School of Physics, The University of Melbourne(墨尔本大学物理学院暗物质粒子物理卓越研究中心);University of South Dakota(南达科他大学)
Exploring Low Energy Excess in MINER with sapphire detectors using Convolutional Variational Autoencoder (CVAE)
National Institute of Science Education and Research(印度科学教育研究所);Homi Bhabha National Institute(霍米·巴巴国立研究所);Texas A&M University(德克萨斯农工大学);Sam Houston State University(山姆休斯顿州立大学);SNOLAB(SNOLAB实验室)
Precision Measurement of a low-loss Cylindrical Dumbbell-Shaped Sapphire Mechanical Oscillator using Radiation Pressure
我们目前的第一个结果,从一个0.53公斤的圆柱形哑铃形蓝宝石晶体上进行的一些实验。这是第一次报道的光学机械实验的这种性质,利用一种新的修改典型的圆柱形架构。晶体结构的机械运动改变了晶体的尺寸,并且引起的应变改变了介电常数。这两种效应导致在晶体内同时激发的谐振微波回音壁模式的参数频率调制。实现了一种新型的低噪声微波读出系统,允许在我们感兴趣的模式附近对该频率调制进行极低噪声测量,在100 kHz处具有-165 dBc/Hz的相位噪声基底。晶体悬浮的微调允许优化机械品质因数,为低温实验做准备,在127 kHz时达到Q=8 x 10^7。这导致10^13的Q x f乘积,相当于宏观蓝宝石机械系统中的最佳测量值。结果表明,通过辐射压力的机械模式的激励,允许实验方法确定换能器的位移灵敏度DF/DX,并校准系统。最后,我们展示了系统中的参数反作用现象。这些都是实现实验总体目标的重要步骤;将宏观器件冷却到毫开尔文温度下的量子基态。