Scintillation balloon for liquid scintillator base Neutrinoless double beta decay search experiments
S. Obara, Y. Gando, K. Ishidoshiro
备注:
3 pages, 4 figures, Proceedings of the 16th International Conference on Topics in Astroparticle and Underground Physics (TAUP 2019), September 9-13, 2019, Toyama, Japan
A liquid scintillator base experiment KamLAND-Zen has set a lower limit on neutrinoless double beta decay half-life, and upgrade project KamLAND-Zen 800 has started in 2019. Unfortunately, this project expects some backgrounds, and one of the main backgrounds is beta/gamma-ray from 214Bi in container of xenon loaded liquid scintillator (mini-balloon). In order to reject the background, we suggest using scintillation film for the future mini-balloon. If we can tag alpha-ray from 214Po by scintillation detection, we can eliminate 214Bi events by delayed coincidence analysis. Recently, it was reported that polyethylene naphthalate (PEN) can be used as a scintillator with blue photon emission. PEN has chemical compatibility for strong solvent, thus it has a possibility to use in liquid scintillator. In this presentation, we will mention the results for feasibility studies about transparency and emission spectra, light yield, radioactivity, strength of film etc.. We also show the test-sized scintillation balloon with an 800-mm diameter and discussions about how to use the scintillation balloon in KamLAND.
Environmental radioactivity is a dominant background for rare decay search experiments, and it is difficult to completely remove such an impurity from detector vessels. We propose a scintillation balloon as the active vessel of a liquid scintillator in order to identify this undesirable radioactivity. According to our feasibility studies, the scintillation balloon enables the bismuth--polonium sequential decay to be tagged with a 99.7\% efficiency, assuming a KamLAND (Kamioka Liquid scintillator AntiNeutrino Detector)-type liquid scintillator detector. This tagging of sequential decay using al…
The gaseous Xenon(Xe) time projection chamber (TPC) is an attractive detector technique for neutrinoless double beta decay and WIMP dark matter searches. While it is less dense compared to Liquid Xe detectors, it has intrinsic advantages in tracking capability and better energy resolution. The performance of gaseous Xe can be further improved by molecular additives such as trimethylamine(TMA), which is expected to (1) cool down the ionization electrons, (2) convert Xe excitation energy to TMA ionizations through Penning transfer, and (3) produce scintillation and electroluminescence light in a…
The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of $^{136}$Xe by using $^{136}$Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spallation products and $^{8}$B solar neutrinos. Indeed these events could contribute to the total counts in the region of interest around the Q-value of the double-beta decay of $^{136}$Xe. In this pape…
Liquid Xe TPCs are among the most popular choices for double beta decay and WIMP dark matter searches. Gaseous Xe has intrinsic advantages when compared to Liquid Xe, specifically, tracking capability and better energy resolution for double beta decay searches. The performance of gaseous Xe can be further improved by molecular additives such as trimethylamine(TMA), which are expected to (1) cool down the ionization electrons, (2) convert Xe excitation energy to TMA ionizations through Penning transfer, and (3) produce scintillation and electroluminescence light in a more easily detectable wave…
The scintillation properties of a $\mathrm{CdMoO_4}$ crystal have been investigated experimentally. The fluorescence yields and decay times measured from 22 K to 300 K demonstrate that $\mathrm{CdMoO_4}$ crystal is a good candidate for an absorber for a bolometer readout, for both heat and scintillation signals. The results from Monte Carlo studies taking the backgrounds from $\mathrm{2\nu2β}$ of $\mathrm{{}_{42}^{100}Mo}$ ($\mathrm{{}_{48}^{116}Cd}$) and internal trace nuclides $\mathrm{{}^{214}Bi}$ and $\mathrm{{}^{208}Tl}$ into account show that the expected sensitivity of $\mathrm{CdMoO_4}…
Compelling experimental evidences of neutrino oscillations and their implication that neutrinos are massive particles have given neutrinoless double beta decay a central role in astroparticle physics. In fact, the discovery of this elusive decay would be a major breakthrough, unveiling that neutrino and antineutrino are the same particle and that the lepton number is not conserved. It would also impact our efforts to establish the absolute neutrino mass scale and, ultimately, understand elementary particle interaction unification. All current experimental programs to search for neutrinoless do…
We present a detector apparatus, DireXeno (DIRectinal Xenon), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments, however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits correlation in light emission such as super-radiance, which depends on the type of interaction. Such properties of scintillation light may open a new window …
The sensitivity of neutrinoless double beta (0n2b) decay experiments is mainly depended on the internal background of a detector which, in its turn, is defined by the purity of material and possibility for selection of background events. The AMoRE (Advanced Mo based Rare process Experiment) collaboration plans to use 40Ca100MoO4 scintillation crystals as a detector for search of 0n2b decay of 100Mo isotope. A purpose of this paper is further investigation of internal background of 40Ca100MoO4 scintillation elements with a low background setup at YangYang underground laboratory. We present new …
The recent development of water-based liquid scintillator and the concurrent development of high-efficiency and high-precision-timing light sensors has opened up the possibility for a new kind of large-scale detector capable of a very broad program of physics. The program would span topics in nuclear, high-energy, and astrophysics, ranging from a next-generation neutrinoless double beta decay search capable of covering the inverted hierarchy region of phase space, to supernova neutrino detection, nucleon decay searches, and measurement of the neutrino mass hierarchy and CP violating phase. Thi…
High light collection efficiency is an important requirement in any application of scintillation detectors. The purpose of this study is to investigate the possibility for improving this parameter in cryogenic scintillation bolometers, which can be considered as a promising detectors in experiments investigating neutrinoless double beta decay and dark matter. Energy resolutions and relative pulse amplitudes of scintillation detectors using ZnWO4 scintillation crystals of different shapes (cylinder 20 mm in dimater by 20 mm and hexagonal prism with diagonal 20 mm and height 20 mm), reflector ma…
The possible use of a Spherical Proportional Counter for the search of neutrinoless double beta decay is investigated in the R2D2 R&D project. Dual charge and scintillation light readout may improve the detector performance. Tests were carried out with pure argon at 1.1 bar using a 6x6 mm2 silicon photomultiplier. Scintillation light was used for the first time to trigger in a spherical proportional counter. The measured drift time is in excellent agreement with the expectations from simulations. Furthermore the light signal emitted during the avalanche development exhibits features that could…
Simulation studies have been carried out to explore the ability to discriminate between single-site and multi-site energy depositions in large scale liquid scintillation detectors. A robust approach has been found that is predicted to lead to a significant statistical separation for a large variety of event classes, providing a powerful tool to discriminate against backgrounds and break important degeneracies in signal extraction. This has particularly relevant implications for liquid scintillator searches for neutrinoless double beta decay ($0νββ$) from $^{130}$Te and $^{136}$Xe, where it is …
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was observed from the energy spectrum fitting with precise background evaluation, and we set a lower limit of the half life of 3.7 $\times$ 10$^{24}$ years at 90$\%$ confidence level. This is the first experim…
We introduce a novel particle detection concept for large-volume, fine granularity particle detection: The Ion Fluorescence Chamber (IFC). In electronegative gases such as SF$_6$ and SeF$_6$, ionizing particles create ensembles of positive and negative ions. In the IFC, positive ions are drifted to a chemically active cathode where they react with a custom organic turn-on fluorescent monolayer encoding a long-lived 2D image. The negative ions are sensed electrically with course resolution at the anode, inducing an optical microscope to travel to and scan the corresponding cathode location for …
Scintillating bolometers of ZnSe are the baseline choice of the LUCIFER experiment, whose aim is to observe the neutrinoless double beta decay of 82Se. The independent read-out of the heat and scintillation signals allows to identify and reject alpha particle interactions, the dominant background source for bolometric detectors. In this paper we report the performances of a ZnSe crystal operated within the LUCIFER R&D. We measured the scintillation yield, the energy resolution and the background in the energy region where the signal from neutrinoless double beta decay of 82Se is expected with …
A large cylindrical cadmium molybdate crystal with natural isotopic abundance has been used to fabricate a scintillating bolometer. The measurement was performed above ground at milli-Kelvin temperature, with simultaneous readout of the heat and the scintillation light. The energy resolution as FWHM has achieved from 5 keV (at 238 keV) to 13 keV (at 2615 keV). We present the results of the $α$ versus $β$/$γ$ events discrimination. The low internal trace contamination of the $\mathrm{CdMoO_4}$ crystal was evaluated as well. The detector performance with preliminary positive indications proves t…
Many rare event searches including dark matter direct detection and neutrinoless double beta decay experiments take advantage of the high VUV reflective surfaces made from polytetrafluoroethylene (PTFE) reflector materials to achieve high light collection efficiency in their detectors. As the detectors have grown in size over the past decade, there has also been an increased need for ever thinner detector walls without significant loss in reflectance to reduce dead volumes around active noble liquids, outgassing, and potential backgrounds. We report on the experimental results to measure the d…
The FlatDot detector has been used to demonstrate the separation of Cherenkov and scintillation light for 1 to 2MeV electrons in linear alkylbenzene (LAB). With an average PMT transit time spread (TTS) of 200ps, the early light in each event is clearly dominated by the Cherenkov signal, which on average comprises $86^{+2}_{-3}\%$ of the light collected in the first 4.1ns of each event. The spatial distributions of the Cherenkov and scintillation light are found to match those predicted in Monte Carlo simulations. This is a key step towards demonstrating direction reconstruction of $β$ decays, …
Performance evaluation of GYGAG crystals for neutrinoless double beta decay search
Research Center for Neutrino Science, Tohoku University(东北大学中微子科学研究中心);Faculty of Engineering, The University of Tokyo(东京大学工学部);Institute for Cosmic Ray Research, The University of Tokyo(东京大学宇宙线研究所)
The GERDA experiment searches for the neutrinoless double beta ($0νββ$) decay in $^{76}$Ge in order to probe whether the neutrino is a Majorana particle and to shed light on the neutrino mass ordering. For investigating such a rare decay it is necessary to minimize the background of the experiment. In Phase II of the GERDA experiment the scintillation light of liquid argon (LAr) is used as an additional background veto. In order to estimate the efficiency of such a LAr veto it has to be known how far the scintillation light, which peaks at 128 nm, can travel within the LAr. A dedicated setup w…
The use of 40Ca100MoO in experimental searches for neutrinoless double beta decay (0νDBD) relies on knowledge of fundamental scintillation properties of the material. In this work we determine the absolute light yield of calcium molybdate using Monte-Carlo refractive index matching technique (MCRIM). The MCRIM technique is a combination of experiment and simulations that allows the absolute light yield of scintillators to be determined by taking into account effects of refraction, scattering and absorption in the material. The light collection efficiency of the scintillator-detector assembly w…
Liquid scintillator detectors are widely used in modern neutrino studies. The unique optical properties of semiconducting nanocrystals, known as quantum dots, offer intriguing possibilities for improving standard liquid scintillator, especially when combined with new photodetection technology. Quantum dots also provide a means to dope scintillator with candidate isotopes for neutrinoless double beta decay searches. In this work, the first studies of the scintillation properties of quantum-dot-doped liquid scintillator using both UV light and radioactive sources are presented.
The timing and spectral characteristics of four highly efficient, slow fluors are presented for liquid scintillator solutions using linear alkylbenzene (LAB) as the primary solvent. The mixtures exhibit high light yields, but with rise times of several ns or more and decay times on the order of tens of ns. Consequently, such liquid scintillator mixtures can be used for effective separation of Cherenkov and scintillation components based on timing in large scale liquid scintillation detectors. Such a separation, showing high light yield and directional information, is demonstrated here on a ben…
The AMoRE is an experiment to search for neutrinoless double-beta decay of 100Mo in molybdate crystal scintillators using a cryogenic detection technique. The crystals are equipped with metallic magnetic calorimeter sensors that detect both phonon and photon signals at temperatures of a few tens of mK. Simultaneous measurements of thermal and scintillation signals produced by particle interactions in the crystals by MMC sensors provide high energy resolution and efficient particle discrimination. AMoRE-Pilot, an R&D phase with six 48deplCa100MoO4 crystals and a total mass of ~1.9 kg in the fin…
ZnMoO$_4$ scintillators with a mass of $\sim$ 0.3 kg, as well as Zn$^{100}$MoO$_4$ crystals enriched in the isotope $^{100}$Mo were produced for the first time by using the low-thermal-gradient Czochralski technique. The optical and luminescent properties of the produced crystals were studied to estimate the progress in crystal growth quality. The low-temperature tests with a 313 g ZnMoO$_4$ and two enriched Zn$^{100}$MoO$_4$ crystals were performed aboveground in the Centre de Sciences Nucléaires et de Sciences de la Matière. The low background measurements with a three ZnMoO$_4$ and two enri…
The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $α$ from $γ$&$β$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addi…
This article reviews the progress made over the last 20 years in the development and applications of liquid xenon detectors in particle physics, astrophysics and medical imaging experiments. We begin with a summary of the fundamental properties of liquid xenon as radiation detection medium, in light of the most current theoretical and experimental information. After a brief introduction of the different type of liquid xenon detectors, we continue with a review of past, current and future experiments using liquid xenon to search for rare processes and to image radiation in space and in medicine…
The R&D for a new type of liquid xenon (LXe) detector is ongoing to search for the neutrinoless double-beta decay ($0\nu2β$). As a result of the KamLAND-Zen experiment, it is very important to realize the all active region detector for the energy deposition of the radiation. Newly developed additional BG reduction techniques will improve the sensitivity of $0\nu2β$ search in the future. Our detector concept is LXe stored in a new type of plastic scintillator vessel. The wavelength of LXe scintillation light is shifted to visible light from 175nm (VUV) on the inner surface of the vessel. Theref…
CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in 2018, and provide results from the first datasets. The demonstrator consists of an array of 20 scintillating bolometers comprised of $^{100}$Mo-enriched 0.2 kg Li$_2$MoO$_4$ crystals. The detectors are complemented by 20 thin cryogenic Ge bolometers acting as light detectors to distinguish $α$ from $γ$/$β$ events by the detection of both heat and scintillation light si…
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and …
The detection of scintillation light from liquid argon is an experimental technique key to a number of current and future nuclear/particle physics experiments, such as neutrino physics, neutrinoless double beta decay and dark matter searches. Although the idea of adding small quantities of xenon (doping) to enhance the light yield has attracted considerable interest, this technique has never been demonstrated at the necessary scale or precision. Here we report on xenon doping in a 100 l cryogenic vessel. Xenon doping was performed in four concentrations of 1.00$\pm$0.06 ppm, 2.0$\pm$0.1 ppm, 5…
Background coming from the $^{42}$Ar decay chain is considered to be one of the most relevant for the GERDA experiment, which aims to search of the neutrinoless double beta decay of $^{76}$Ge. The sensitivity strongly relies on the absence of background around the Q-value of the decay. Background coming from $^{42}$K, a progeny of $^{42}$Ar, can contribute to that background via electrons from the continuous spectrum with an endpoint of 3.5 MeV. Research and development on the suppression methods targeting this source of background were performed at the low-background test facility LArGe. It w…
NEXT-DEMO is a 1:4.5 scale prototype of the NEXT100 detector, a high-pressure xenon gas TPC that will search for the neutrinoless double beta decay of $^{136}$Xe. X-ray energy depositions produced by the de-excitation of Xenon atoms after the interaction of gamma rays from radioactive sources have been used to characterize the response of the detector obtaining the spatial calibration needed for close-to-optimal energy resolution. Our result, 5.5% FWHM at 30 keV, extrapolates to 0.6% FWHM at the Q value of $^{136}$Xe. Additionally, alpha decays from radon have been used to measure several dete…
Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted when particles interact in the bolometer is a promising method to lower the background of the experiments. The different amount of light emitted in beta/gamma and alpha interactions, whether due to scintillation or Cerenkov emission, allows to discriminate the two interaction types. Because of the cryogenic environment, light detectors are often bolometers. I…
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the …
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolutio…
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution (<1%), very low background con- tamination (1E-4 counts/(keV \bullet kg \bullet y)) and large target mass. In addition, it needs to be operational as soon as possible. The design described here optimi…
The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn$^{82}$Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali …
The GERmanium Detector Array GERDA experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN, searches for $0νββ$ of $^{76}$Ge. Germanium diodes enriched to $\sim 86~\%$ in the double beta emitter $^{76}$Ge ($^{enr}$Ge) are exposed being both source and detectors of $0νββ$ decay. Neutrinoless double beta decay is considered a powerful probe to address still open issues in the neutrino sector of the (beyond) Standard Model of particle Physics. Since 2013, just after the completion of the first part of its experimental program (Phase I), the GERDA setup has been upgraded to p…
NEXT (Neutrino Experiment with a Xenon TPC) aims to observe the neutrinoless double beta decay of \ensuremath{{}^{136}\rm Xe} in a high-pressure gas xenon Time Projection Chamber using electroluminescence to amplify the signal from ionization. The two main advantages of this technology are a high energy resolution and the possibility of reconstructing electron tracks. NEXT-100 is an electroluminescent, asymmetric TPC which will host 100 kg of the \ensuremath{{}^{136}\rm Xe} isotope at 15 bar of pressure. On one side, a sparse array of photomultipliers records both the primary scintillation sig…
In the past few decades, numerous searches have been made for the neutrinoless double-beta decay (0$νββ$) process, aiming to establish whether neutrinos are their own antiparticles (Majorana neutrinos), but no 0$νββ$ decay signal has yet been observed. A number of new experiments are proposed but they ultimately suffer from a common problem: the sensitivity may not increase indefinitely with the target mass. We have performed a detailed analysis of the physics potential by using the Jiangmen Underground Neutrino Observatory (JUNO) to improve the sensitivity to 0$νββ$ up to a few meV, a major s…
The recent development of Water-based Liquid Scintillator (WbLS), and the concurrent development of high-efficiency and high-precision-timing light sensors, has opened up the possibility for a new kind of large-scale detector capable of a very broad program of physics. The program would include determination of the neutrino mass hierarchy and observation of CP violation with long-baseline neutrinos, searches for proton decay, ultra-precise solar neutrino measurements, geo- and supernova neutrinos including diffuse supernova antineutrinos, and neutrinoless double beta decay. We outline here the…
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improveme…
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \m…
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching …
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve hi…
Muon veto system for the CROSS double-beta decay search experiment
National Research Center Kurchatov Institute(库尔恰托夫国立研究中心);CNRS/IN2P3(法国国家科学研究中心/欧洲核子研究学院);IJCLab(伊夫林-约讷实验室);INFN Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所格兰萨索国家实验室);Institute for Nuclear Research of NASU(乌克兰国家科学院核物理研究所);Institute of Experimental and Applied Physics, CTU Prague(布拉格捷克理工大学实验与应用物理研究所)
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured …
A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
CNRS/IN2P3(法国国家科学研究中心/欧洲核子研究学会);National Research Center Kurchatov Institute(库尔恰托夫国家研究中心);Institute for Nuclear Research of NASU(乌克兰国家科学院核物理研究所);INFN Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所大萨索国家实验室);University College London(伦敦大学学院)