arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1407.4608physics.ins-dethep-ex
收藏

用于稀有事件搜索的柔性闪烁光装置

A flexible scintillation light apparatus for rare event searches

Valter Bonvicini, Silvia Capelli, Oliviero Cremonesi, Giacomo Cucciati, Luca Gironi, Maura Pavan, Ezio Previtali, Monica Sisti

摘要:

中微子振荡的有力实验证据以及中微子是大质量粒子的暗示,使无中微子双β衰变在天体粒子物理学中扮演了核心角色。事实上,发现这种难以捉摸的衰变将是一个重大突破,揭示中微子和反中微子是同一种粒子,轻子数不守恒。这也将影响我们建立绝对中微子质量尺度的努力,并最终理解基本粒子相互作用的统一。目前所有寻找无中微子双β衰变的实验计划都面临着技术和财政上的挑战,即在增加实验质量的同时保持令人难以置信的低水平的虚假背景。本文描述的新概念可能是答案,它结合了理想实验的所有特征:能量分辨率,低成本质量可扩展性,同位素选择的灵活性和许多强大的处理,使背景可以忽略不计。所提出的技术是基于使用冷却到120 K的硅探测器阵列来优化超纯晶体发射的闪烁光的收集。结果表明,用54公斤的这种类型的天然CaMoO_4闪烁探测器阵列,在一年的数据采集中,就有可能对~(100)Mo的无中微子双β衰变的半衰期产生高达~ 10 E ~(24)年的有竞争力的灵敏度。用40 CaMoO 4闪烁探测器(为了消除48 Ca的两个中微子双β衰变产生的连续背景)制成的相同阵列,将能够在仅一年的测量中实现对100 Mo无中微子双β衰变半衰期的~ 10 E25年的显著灵敏度。

英文摘要:

Compelling experimental evidences of neutrino oscillations and their implication that neutrinos are massive particles have given neutrinoless double beta decay a central role in astroparticle physics. In fact, the discovery of this elusive decay would be a major breakthrough, unveiling that neutrino and antineutrino are the same particle and that the lepton number is not conserved. It would also impact our efforts to establish the absolute neutrino mass scale and, ultimately, understand elementary particle interaction unification. All current experimental programs to search for neutrinoless double beta decay are facing with the technical and financial challenge of increasing the experimental mass while maintaining incredibly low levels of spurious background. The new concept described in this paper could be the answer which combines all the features of an ideal experiment: energy resolution, low cost mass scalability, isotope choice flexibility and many powerful handles to make the background negligible. The proposed technology is based on the use of arrays of silicon detectors cooled to 120 K to optimize the collection of the scintillation light emitted by ultra-pure crystals. It is shown that with a 54 kg array of natural CaMoO4 scintillation detectors of this type it is possible to yield a competitive sensitivity on the half-life of the neutrinoless double beta decay of 100Mo as high as ~10E24 years in only one year of data taking. The same array made of 40CaMoO4 scintillation detectors (to get rid of the continuous background coming from the two neutrino double beta decay of 48Ca) will instead be capable of achieving the remarkable sensitivity of ~10E25 years on the half-life of 100Mo neutrinoless double beta decay in only one year of measurement.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑