液态氩中Cosmic-Ray μ子的闪烁光

Scintillation Light from Cosmic-Ray Muons in Liquid Argon

Denver Whittington, Stuart Mufson, Bruce Howard

摘要:

本文报道了直接测量宇宙线μ子通过液氩时的时间分辨闪烁信号的实验结果。这些μ子产生的闪烁光对中微子实验和暗物质研究中弱相互作用粒子的研究具有重要价值。实验是在费米实验室的TallBo杜瓦瓶设施中进行的,使用的是为深层地下中微子实验开发的原型光导探测器和电子设备。提出了两种闪烁光时间结构的模型:唯象模型和复合模型。这两种模型发现$τ_{\text{T}} = 1.52$ $μ$ s的Ar $_2^*$三重态的衰变时间常数。这些模型还表明,“早期”的光部分的现象学模型,$F_{\text{E}}\approx 25\%$的信号,与总的光从单重态衰变的识别是低估。单线态光的总分数是$F_{\text{S}} \approx 36\%$,其中超过$F_{\text{E}}$的增加来自波长移位器通过具有长衰减常数的过程发射的单线态光。该模型还用于计算实验粒子识别参数$F_{\text{prompt}}$,即与总记录波形中的光相比,在触发后的短时间窗口中进入的光的分数。该模型再现相当好的典型的实验值$\sim0.3$发现暗物质和双$β$衰变实验,这表明该参数提供了一个强大的度量更严重的电离粒子的歧视电子和μ子。

英文摘要:

This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a composite model. Both models find $τ_{\text{T}} = 1.52$ $μ$s for the decay time constant of the Ar$_2^*$ triplet state. These models also show that the identification of the "early" light fraction in the phenomenological model, $F_{\text{E}}\approx 25\%$ of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is $F_{\text{S}} \approx 36\%$, where the increase over $F_{\text{E}}$ is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter $F_{\text{prompt}}$, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value $\sim0.3$ found by dark matter and double $β$-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑