摘要:

自外差光纤干涉仪已经被证明能够将激光器稳定到超窄线宽,并为高精细腔的频率稳定提供了一个很好的替代方案。除了抑制频率噪声,这些器件是高度可调谐的,并且可以被操纵以在激光器的整个范围内产生高速频率扫描。我们提出了一种分析方法来选择延迟线的长度为最佳的噪声抑制和最高的环路频率扫描速率。使用这个模型,我们已经实现了一个基于光纤的有源迈克耳孙干涉仪作为一个传统的二极管激光器的频率放大器,并证明了700赫兹的线宽超过毫秒的时间尺度。我们还演示了1 THz/s的频率扫描速率,并独立测量线性扫描频率的最大偏差为100 kHz,主要受装置中的声共振限制。

英文摘要:

Self-heterodyne fiber interferometers have been shown to be capable of stabilizing lasers to ultra-narrow linewidths and present an excellent alternative to high finesse cavities for frequency stabilization. In addition to suppressing frequency noise, these devices are highly tunable, and can be manipulated to produce high speed frequency sweeps over the entire range of the laser. We present an analytic approach for choosing a delay-line length for both optimal noise suppression and highest in-loop frequency sweep rate. Using this model we have implemented a fiber-based active Michelson interferometer as a frequency discriminator for a conventional diode laser and demonstrated a linewidth of 700 Hz over millisecond timescales. We also demonstrate a frequency scan rate of 1 THz/s and independently measure the maximum deviation in frequency from the linear sweep to be 100 kHz, predominantly limited by acoustic resonances in the apparatus.