基于稀疏电压电流混合测量的网状电网故障定位算法

An Accurate Fault Location Algorithm for Meshed Power Networks Utilizing Hybrid Sparse Voltage and Current Measurements

Adil Khan, Abdul Qayyum Khan, Muhammad Sarwar, Muhammad Abubakar, Naeem Iqbal

摘要:

提出了一种基于稀疏电压和稀疏电流相量混合同步测量的精确故障定位算法。该算法解决了仅基于同步稀疏电压测量(SSVM)和仅基于同步稀疏电流测量(SSCM)的故障定位算法的性能限制。该方法利用故障线路或其附近母线的电压相量和相邻线路的支路电流相量。本文提出的电压电流混合测量方法有助于提高故障测距的准确性,并能有效地消除电流互感器饱和的影响。该算法已在四节点两区域电力系统和IEEE 14节点系统上进行了测试,并具有实际配电系统的典型特征。通过故障位置、故障电阻、负荷切换等参数的变化,验证了算法的鲁棒性。仿真结果验证了该算法的准确性,保证了可靠的故障检测和定位方法。

英文摘要:

This paper proposes an accurate fault location algorithm technique based on hybrid synchronized sparse voltage and sparse current phasor measurements. The proposed algorithm addresses the performance limitation of fault location algorithms based on only synchronized sparse voltage measurements (SSVM) and on only synchronized sparse current measurements (SSCM). In the proposed method, bus voltage phasor of faulty line or close to the faulty line and branch current phasor of the adjacent line is utilized. The paper contributes to improve the accuracy of fault location and deter the effect of CT saturation by using hybrid voltage and current measurements. The proposed algorithm has been tested on four bus two area power system and IEEE 14 bus system with the typical features of an actual distribution system. The robustness of algorithm has been tested by variation in fault location, fault resistance, load switching. The simulation results demonstrate the accuracy of the proposed algorithm and ensure a reliable fault detection and location method.