A Real-time Image Reconstruction System for Particle Treatment Planning Using Proton Computed Tomography (pCT)
Caesar E. Ordoñez, Nicholas Karonis, Kirk Duffin, George Coutrakon, Reinhard Schulte, Robert Johnson, Mark Pankuch
备注:
Paper presented at Conference on the Application of Accelerators in Research and Industry, CAARI 2016, 30 October to 4 November 2016, Ft. Worth, TX, USA
Proton computed tomography (pCT) is a novel medical imaging modality for mapping the distribution of proton relative stopping power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range uncertainty margins are around 3.5%, pCT has the potential to provide more accurate measurements to within 1%. This improved efficiency will be beneficial to proton-therapy planning and pre-treatment verification. A prototype pCT imaging device has recently been developed capable of rapidly acquiring low-dose proton radiographs of head-sized objects. We have also developed an advanced, fast image reconstruction software based on distributed computing that utilizes parallel processors and graphical processing units. The combination of fast data acquisition and fast image reconstruction will enable the availability of RSP images within minutes for use in clinical settings. The performance of our image reconstruction software has been evaluated using data collected by the prototype pCT scanner from several phantoms.
Performance of Hull-Detection Algorithms For Proton Computed Tomography Reconstruction
Baylor University(贝勒大学);California State University, San Bernardino(加州州立大学圣贝纳迪诺分校);University of Haifa(海法大学);Loma Linda University Medical Center(洛马林达大学医学中心)
Total variation superiorization schemes in proton computed tomography image reconstruction
目的:迭代投影重建算法是目前质子计算机断层成像(pCT)的首选重建方法。然而,由于质子能量离散和多次库仑散射引起的测量数据的不一致性,重建图像中的噪声随着连续迭代而增加。在目前的工作中,我们研究了使用全变差优化(TVS)计划,可以作为一个算法的附加扰动弹性迭代投影算法的pCT图像重建。研究方法:块迭代对角松弛正交投影(DROP)算法用于重建Geant 4 Monte Carlo模拟pCT数据集。两个TVS计划添加到DROP进行了研究,第一次进行了superiorization的步骤,每个周期一次,第二次每个块一次。这些计划的简化,包括消除计算昂贵的可行性邻近检查步骤的TVS框架,也进行了研究。调制传递函数和对比度判别函数分别用于量化空间和密度分辨率。结果:与标准DROP算法相比,这两种TVS方案实现了更高的空间和密度分辨率。消除可行性邻近检查提高了图像质量,特别是图像噪声,在每块一次的优越化,同时也减半图像重建时间。总体而言,当每个组织块执行一次优越化并消除可行性邻近检查时,观察到最佳图像质量。结论:TVS使低对比度成像成为可能,有望将其纳入我们未来的pCT研究。
Proton Computed Tomography Image Reconstruction Based on the Richardson-Lucy Algorithm
HUN-REN Wigner Research Centre for Physics(匈牙利科学院维格纳物理研究中心);ELTE Eötvös Loránd University, Institute of Physics(罗兰大学物理研究所);National Institute of Oncology(国家肿瘤研究所);Budapest University of Technology and Economics, Institute of Nuclear Techniques(布达佩斯技术与经济大学核技术研究所)
我们正在探索低剂量质子射线照相术和计算机断层成像(pCT)技术,以提高质子治疗计划的准确性,并在治疗时提供无伪影图像进行验证和适应性治疗。在这里,我们报告了我们的原型pCT头部扫描仪的全面光束测试结果。探测器系统和数据采集可实现每秒超过一百万个单独测量的质子的持续速率,允许在六分钟或更短的射束时间内完成完整的CT扫描。为了评估质子射线照相以及计算机断层成像扫描仪的性能,我们在Northwestern Medicine Chicago质子中心进行了多次体模扫描,包括设计用于评估空间分辨率的定制体模、评估相对阻止本领测量的体模和剂量测定体模。一些图像,性能,和剂量测定结果,从这些幻影扫描的仪器,数据采集系统和校准方法的描述一起。
Reconstruction of proton relative stopping power with a granular calorimeter detector model
University of Kaiserslautern-Landau(凯泽斯劳滕-兰道大学);University of Bergen(卑尔根大学);HUN-REN Wigner Research Centre for Physics(匈牙利研究与教育网络维格纳物理研究中心);Research and Production Enterprise ”LTU” (RPELTU)(LTU研究与生产企业);Institute for Subatomic Physics, Utrecht University/Nikhef(乌得勒支大学/尼赫夫亚原子物理研究所);St. Petersburg University(圣彼得堡大学);Western Norway University of Applied Sciences(西挪威应用科学大学)
Towards order of magnitude X-ray dose reduction in breast cancer imaging using phase contrast and deep denoising
The University of Melbourne(墨尔本大学);The University of Sydney(悉尼大学);Eastern Health(东部健康);Monash Health(莫纳什健康);Monash University(莫纳什大学);Australian Synchrotron, ANSTO(澳大利亚同步辐射中心,ANSTO);Commonwealth Scientific and Industrial Research Organisation(澳大利亚联邦科学与工业研究组织)
Domain Adaptation of Automated Treatment Planning from Computed Tomography to Magnetic Resonance
University of Toronto(多伦多大学);Techna Institute, University Health Network(大学健康网络泰克纳研究所);Princess Margaret Cancer Center(玛格丽特公主癌症中心);Peter Munk Cardiac Center, University Health Network(大学健康网络彼得·蒙克心脏中心);Joint Department of Medical Imaging, University Health Network(大学健康网络医学影像联合部);Vector Institute(矢量研究所)
COBRA2026: a large-scale multicenter pelvic cone-beam computed tomography projection dataset
University of Bern(伯尔尼大学);LMU Munich(慕尼黑大学);University Hospital of Cologne(科隆大学医院);University Medical Center Utrecht(乌得勒支大学医学中心);Medical University of Graz(格拉茨医科大学);Lund University(隆德大学);Skåne University Hospital(斯卡奈大学医院)
Voxel-Based Dose Prediction with Multi-Patient Atlas Selection for Automated Radiotherapy Treatment Planning
放射治疗计划过程的自动化是一个技术上具有挑战性的问题。大多数自动化方法集中于定制和推断剂量体积目标以用于计划优化。在这项工作中,我们概述了一个多病人的图集为基础的剂量预测方法,学习预测剂量每体素的一个新的病人直接从计算机断层成像(CT)计划扫描,而不需要指定任何目标。我们的方法学会自动为新患者选择最有效的图谱,然后将这些图谱中的剂量映射到新患者身上。我们扩展我们以前的工作,包括一个有条件的随机场的联合分布之前,匹配的互补目标的准确的空间分布的剂量分布,同时仍然坚持所需的剂量体积直方图的优化。然后,所得到的分布可以用于具有新的空间剂量目标的逆规划,或者用于为规范优化管道创建典型的剂量体积目标。我们调查了6个治疗部位(633例患者用于培训,113例患者用于测试),并评估了所有DVH的临床和预测剂量分布的平均绝对差(MAD)。与我们以前的方法相比,平均结果是有利的(1.91 vs 2.57)。将我们的方法与有和没有图谱选择进行比较,进一步验证了图谱选择平均改善了全乳腺中的剂量预测。(0.64 vs 1.59),前列腺(2.13对4.07),和直肠(1.46 vs 3.29),而在乳腺腔中不太重要(0.79 vs 0.92)和肺(1.33 vs 1.27),具有高度一致性和最小剂量成形。在CNS脑中,图谱选择具有潜在的影响力(3.65 vs 5.09),但选择理想的图谱是最具挑战性的。
SynthRAD2023 Grand Challenge dataset: generating synthetic CT for radiotherapy
University Medical Center Groningen, University of Groningen(格罗宁根大学医学中心,格罗宁根大学);Radboud University Medical Center(拉德堡德大学医学中心);University Medical Center Utrecht(乌得勒支大学医学中心)
Fast PET Scan Tumor Segmentation using Superpixels, Principal Component Analysis and K-means Clustering
Erasmus+ Joint Program in Medical Imaging and Applications, University of Burgundy (France), UNICLAM (Italy) and University of Girona (Spain)(伊拉斯谟+医学影像与应用联合项目,勃艮第大学(法国)、UNICLAM(意大利)与赫罗纳大学(西班牙))