Purpose: Multiple Coulomb scattering (MCS) poses a challenge in proton CT (pCT) image reconstruction. The assumption of straight paths is replaced with Bayesian models of the most likely path (MLP). Current MLP-based pCT reconstruction approaches assume a water scattering environment. We propose an MLP formalism based on accurate determination of scattering moments in inhomogeneous media. Methods: Scattering power relative to water (RScP) was calculated for a range of human tissues and investigated against relative stopping power (RStP). Monte Carlo simulation was used to compare the new inhomogeneous MLP formalism to the water approach in a slab geometry and a human head phantom. An MLP-Spline-Hybrid method was investigated for improved computational efficiency. Results: A piecewise-linear correlation between RStP and RScP was shown, which may assist in iterative pCT reconstruction. The inhomogeneous formalism predicted Monte Carlo proton paths through a water cube with thick bone inserts to within 1.0 mm for beams ranging from 210 to 230 MeV incident energy. Improvement in accuracy over the conventional MLP ranged from 5% for a 230 MeV beam to 17% for 210 MeV. There was no noticeable gain in accuracy when predicting 200 MeV proton paths through a clinically relevant human head phantom. The MLP-Spline-Hybrid method reduced computation time by half while suffering negligible loss of accuracy. Conclusions: We have presented an MLP formalism that accounts for material composition. In most clinical cases a water scattering environment can be assumed, however in certain cases of significant heterogeneity the proposed algorithm may improve proton path estimation.
Performance of Hull-Detection Algorithms For Proton Computed Tomography Reconstruction
Baylor University(贝勒大学);California State University, San Bernardino(加州州立大学圣贝纳迪诺分校);University of Haifa(海法大学);Loma Linda University Medical Center(洛马林达大学医学中心)
Proton Computed Tomography Image Reconstruction Based on the Richardson-Lucy Algorithm
HUN-REN Wigner Research Centre for Physics(匈牙利科学院维格纳物理研究中心);ELTE Eötvös Loránd University, Institute of Physics(罗兰大学物理研究所);National Institute of Oncology(国家肿瘤研究所);Budapest University of Technology and Economics, Institute of Nuclear Techniques(布达佩斯技术与经济大学核技术研究所)
我们正在探索低剂量质子射线照相术和计算机断层成像(pCT)技术,以提高质子治疗计划的准确性,并在治疗时提供无伪影图像进行验证和适应性治疗。在这里,我们报告了我们的原型pCT头部扫描仪的全面光束测试结果。探测器系统和数据采集可实现每秒超过一百万个单独测量的质子的持续速率,允许在六分钟或更短的射束时间内完成完整的CT扫描。为了评估质子射线照相以及计算机断层成像扫描仪的性能,我们在Northwestern Medicine Chicago质子中心进行了多次体模扫描,包括设计用于评估空间分辨率的定制体模、评估相对阻止本领测量的体模和剂量测定体模。一些图像,性能,和剂量测定结果,从这些幻影扫描的仪器,数据采集系统和校准方法的描述一起。
Total variation superiorization schemes in proton computed tomography image reconstruction
目的:迭代投影重建算法是目前质子计算机断层成像(pCT)的首选重建方法。然而,由于质子能量离散和多次库仑散射引起的测量数据的不一致性,重建图像中的噪声随着连续迭代而增加。在目前的工作中,我们研究了使用全变差优化(TVS)计划,可以作为一个算法的附加扰动弹性迭代投影算法的pCT图像重建。研究方法:块迭代对角松弛正交投影(DROP)算法用于重建Geant 4 Monte Carlo模拟pCT数据集。两个TVS计划添加到DROP进行了研究,第一次进行了superiorization的步骤,每个周期一次,第二次每个块一次。这些计划的简化,包括消除计算昂贵的可行性邻近检查步骤的TVS框架,也进行了研究。调制传递函数和对比度判别函数分别用于量化空间和密度分辨率。结果:与标准DROP算法相比,这两种TVS方案实现了更高的空间和密度分辨率。消除可行性邻近检查提高了图像质量,特别是图像噪声,在每块一次的优越化,同时也减半图像重建时间。总体而言,当每个组织块执行一次优越化并消除可行性邻近检查时,观察到最佳图像质量。结论:TVS使低对比度成像成为可能,有望将其纳入我们未来的pCT研究。
Experimental Demonstration of Soft-Tissue Muon Scattering Tomography
CERN, European Organization for Nuclear Research(欧洲核子研究中心);ETH Zürich(苏黎世联邦理工学院);Instituto de Física Corpuscular (CSIC/Universitat de València)(粒子物理研究所(西班牙科学理事会/瓦伦西亚大学))
Reconstruction of proton relative stopping power with a granular calorimeter detector model
University of Kaiserslautern-Landau(凯泽斯劳滕-兰道大学);University of Bergen(卑尔根大学);HUN-REN Wigner Research Centre for Physics(匈牙利研究与教育网络维格纳物理研究中心);Research and Production Enterprise ”LTU” (RPELTU)(LTU研究与生产企业);Institute for Subatomic Physics, Utrecht University/Nikhef(乌得勒支大学/尼赫夫亚原子物理研究所);St. Petersburg University(圣彼得堡大学);Western Norway University of Applied Sciences(西挪威应用科学大学)
Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report
Radiation Physics, Department of Hematology, Oncology;Radiation Physics, Skåne University Hospital, Lund, Sweden;Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden;Radiotherapy Department, University Medical Center Utrecht, Utrecht, The Netherlands;Computational Imaging Group for MR Diagnostics \& Therapy, University Medical Center Utrecht, Utrecht, The Netherlands;Division of Medical Physics in Radiation Oncology, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Germany;Heidelberg Institute for Radiation Oncology (HIRO);National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany;Department of Radiation Oncology;Cyberknife Center, University Hospital of Cologne, Cologne, Germany;Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands;Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands;Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany;Bavarian Cancer Research Center (BZKF), Munich, Germany;Australian eHealth Research Center, CSIRO, Brisbane, Australia;School of Computer Science, University of Sydney, Sydney, Australia;Department of Orthodontics;Pattern Recognition Lab, FAU Erlangen-Nuremberg, Germany;RIKEN Center for Integrative Medical Sciences, Tokyo, Japan;Erasmus Mundus Joint Master's Degree IPCVai, University of Bordeaux, France;Computer Science, Huazhong University of Science;Huazhong University of Science;Canon Medical Systems (China) CO., LTD., Beijing, China;Department of Radiation Oncology, Inselspital, Bern University Hospital;University of Bern, Bern, Switzerland