arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1704.06330cond-mat.mes-hallphysics.app-ph
收藏

耗散调制开尔文探针力显微镜法

Dissipation modulated Kelvin probe force microscopy method

Yoichi Miyahara, Peter Grutter

摘要:

介绍了一种利用调频原子力显微镜(FM-AFM)的耗散信号作为直流偏置电压反馈(D-KPFM)的Kelvin探针力显微镜(KPFM)的实现方法。耗散产生于振荡的静电力,该静电力与尖端振荡相干,尖端振荡是通过在尖端和样品之间施加交流电压而引起的。外部诱导耗散的大小被发现是成比例的有效直流偏置电压,这是所施加的直流电压和接触电势差之间的差异。提出了两种不同的D-KPFM实现方案。在第一实施方式中,所施加的交流电压的频率$f_\mathrm{el}$被选择为与尖端振荡相同($f_\mathrm{el} = f_\mathrm{m}$:$1ω$ D-KPFM)。在第二种情况下,交流电压频率$f_\mathrm{el}$选择为尖端振荡频率的两倍($f_\mathrm{el}= 2 f_\mathrm{m}$:$2ω$ D-KPFM)。在$1ω$ D-KPFM中,耗散与静电力成比例,这使得可以使用甚至低至$\approx 10$ \,mV的小交流电压幅度。在$2ω$ D-KPFM中,耗散与静电力梯度成比例,这导致与FM-KPFM获得的电势对比度相同。D-KPFM的特点是实现简单,没有锁定放大器,扫描速度更快,因为它不需要低频调制。在$1ω$ D-KPFM中使用小的交流电压幅度对于表征技术相关材料具有重要意义,在这些材料中,它们的电性能可能被施加的电场干扰。当需要更精确的电位测量时,$2ω$ D-KPFM非常有用。$1ω$和$2ω$ D-KPFM中的操作可以轻松切换,以便在样品的同一位置利用这两种功能。

英文摘要:

We review a new implementation of Kelvin probe force microscopy (KPFM) in which the dissipation signal of frequency modulation atomic force microscopy (FM-AFM) is used for dc bias voltage feedback (D-KPFM). The dissipation arises from an oscillating electrostatic force that is coherent with the tip oscillation, which is caused by applying the ac voltage between the tip and sample. The magnitude of the externally induced dissipation is found to be proportional to the effective dc bias voltage, which is the difference between the applied dc voltage and the contact potential difference. Two different implementations of D-KPFM are presented. In the first implementation, the frequency of the applied ac voltage, $f_\mathrm{el}$, is chosen to be the same as the tip oscillation ($f_\mathrm{el} = f_\mathrm{m}$: $1ω$D-KPFM). In the second one, the ac voltage frequency, $f_\mathrm{el}$, is chosen to be twice the tip oscillation frequency ($f_\mathrm{el}= 2 f_\mathrm{m}$: $2ω$D-KPFM). In $1ω$D-KPFM, the dissipation is proportional to the electrostatic force, which enables the use of a small ac voltage amplitude even down to $\approx 10$\,mV. In $2ω$D-KPFM, the dissipation is proportional to the electrostatic force gradient, which results in the same potential contrast as that obtained by FM-KPFM. D-KPFM features a simple implementation with no lock-in amplifier and faster scanning as it requires no low frequency modulation. The use of a small ac voltage amplitude in $1ω$D-KPFM is of great importance in characterizing of technically relevant materials in which their electrical properties can be disturbed by the applied electric field. $2ω$D-KPFM is useful when more accurate potential measurement is required. The operations in $1ω$ and $2ω$D-KPFM can be switched easily to take advantage of both features at the same location on a sample.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑