Planck 2015 results. II. Low Frequency Instrument data processing
Planck Collaboration, P. A. R. Ade, N. Aghanim, M. Ashdown, J. Aumont, C. Baccigalupi, M. Ballardini, A. J. Banday, R. B. Barreiro, N. Bartolo, S. Basak, P. Bat… 展开作者
Planck Collaboration, P. A. R. Ade, N. Aghanim, M. Ashdown, J. Aumont, C. Baccigalupi, M. Ballardini, A. J. Banday, R. B. Barreiro, N. Bartolo, S. Basak, P. Battaglia, E. Battaner, K. Benabed, A. Benoît, A. Benoit-Lévy, J. -P. Bernard, M. Bersanelli, P. Bielewicz, J. J. Bock, A. Bonaldi, L. Bonavera, J. R. Bond, J. Borrill, F. R. Bouchet, M. Bucher, C. Burigana, R. C. Butler, E. Calabrese, J. -F. Cardoso, G. Castex, A. Catalano, A. Chamballu, P. R. Christensen, S. Colombi, L. P. L. Colombo, B. P. Crill, A. Curto, F. Cuttaia, L. Danese, R. D. Davies, R. J. Davis, P. de Bernardis, A. de Rosa, G. de Zotti, J. Delabrouille, C. Dickinson, J. M. Diego, H. Dole, S. Donzelli, O. Doré, M. Douspis, A. Ducout, X. Dupac, G. Efstathiou, F. Elsner, T. A. Enßlin, H. K. Eriksen, J. Fergusson, F. Finelli, O. Forni, M. Frailis, C. Franceschet, E. Franceschi, A. Frejsel, S. Galeotta, S. Galli, K. Ganga, M. Giard, Y. Giraud-Héraud, E. Gjerløw, J. González-Nuevo, K. M. Górski, S. Gratton, A. Gregorio, A. Gruppuso, F. K. Hansen, D. Hanson, D. L. Harrison, S. Henrot-Versillé, D. Herranz, S. R. Hildebrandt, E. Hivon, M. Hobson, W. A. Holmes, A. Hornstrup, W. Hovest, K. M. Huffenberger, G. Hurier, A. H. Jaffe, T. R. Jaffe, M. Juvela, E. Keihänen, R. Keskitalo, K. Kiiveri, T. S. Kisner, J. Knoche, N. Krachmalnicoff, M. Kunz, H. Kurki-Suonio, G. Lagache, A. Lähteenmäki, J. -M. Lamarre, A. Lasenby, M. Lattanzi, C. R. Lawrence, J. P. Leahy, R. Leonardi, J. Lesgourgues, F. Levrier, M. Liguori, P. B. Lilje, M. Linden-Vørnle, V. Lindholm, M. López-Caniego, P. M. Lubin, J. F. Macías-Pérez, G. Maggio, D. Maino, N. Mandolesi, A. Mangilli, M. Maris, P. G. Martin, E. Martínez-González, S. Masi, S. Matarrese, P. Mazzotta, P. McGehee, P. R. Meinhold, A. Melchiorri, L. Mendes, A. Mennella, M. Migliaccio, S. Mitra, L. Montier, G. Morgante, N. Morisset D. Mortlock, A. Moss, D. Munshi, J. A. Murphy, P. Naselsky, F. Nati, P. Natoli, C. B. Netterfield, H. U. Nørgaard-Nielsen, D. Novikov, I. Novikov, N. Oppermann, F. Paci, L. Pagano, D. Paoletti, B. Partridge, F. Pasian, G. Patanchon, T. J. Pearson, M. Peel, O. Perdereau, L. Perotto, F. Perrotta, V. Pettorino, F. Piacentini, E. Pierpaoli, D. Pietrobon, E. Pointecouteau, G. Polenta, G. W. Pratt, G. Prézeau, S. Prunet, J. -L. Puget, J. P. Rachen, R. Rebolo, M. Reinecke, M. Remazeilles, A. Renzi, G. Rocha, E. Romelli, C. Rosset, M. Rossetti, G. Roudier, J. A. Rubiňo-Martín, B. Rusholme, M. Sandri, D. Santos, M. Savelainen, D. Scott, M. D. Seiffert, E. P. S. Shellard, L. D. Spencer, V. Stolyarov, D. Sutton, A. -S. Suur-Uski, J. -F. Sygnet, J. A. Tauber, D. Tavagnacco, L. Terenzi, L. Toffolatti, M. Tomasi, M. Tristram, M. Tucci, J. Tuovinen, M. Türler, G. Umana, L. Valenziano, J. Valiviita, B. Van Tent, T. Vassallo, P. Vielva, F. Villa, L. A. Wade, B. D. Wandelt, R. Watson, I. K. Wehus, A. Wilkinson, D. Yvon, A. Zacchei, A. Zonca
We present an updated description of the Planck Low Frequency Instrument (LFI) data processing pipeline, associated with the 2015 data release. We point out the places where our results and methods have remained unchanged since the 2013 paper and we highlight the changes made for the 2015 release, describing the products (especially timelines) and the ways in which they were obtained. We demonstrate that the pipeline is self-consistent (principally based on simulations) and report all null tests. For the first time, we present LFI maps in Stokes Q and U polarization. We refer to other related papers where more detailed descriptions of the LFI data processing pipeline may be found if needed.
This thesis is the result of my work as research fellow at IASF-MI, Milan section of the Istituto di Astrofisica Spaziale e Fisica Cosmica, part of INAF, Istituto Nazionale di Astrofisica. This work started in January 2006 in the context of the PhD school program in Astrophysics held at the Physics Department of Universita' degli Studi di Milano under the supervision of Aniello Mennella. The main topic of my work is the software modelling of the Low Frequency Instrument (LFI) radiometers. The LFI is one of the two instruments on-board the European Space Agency Planck Mission for high precision…
The High Frequency Instrument of Planck will map the entire sky in the millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented sensitivity to polarization ($ΔP/T_{\tiny cmb} \sim 4\cdot 10^{-6}$) at 100, 143, 217 and 353 GHz. It will lead to major improvements in our understanding of the Cosmic Microwave Background anisotropies and polarized foreground signals. Planck will make high resolution measurements of the $E$-mode spectrum (up to $\ell \sim 1500$) and will also play a prominent role in the search for the faint imprint of primordial gravitational waves on the CMB pol…
We report on the search for optical counterparts of Planck Sunyaev-Zel'dovich (SZ) cluster candidates using a 0.6 meter non-professional telescope. Among the observed sources, an unconfirmed candidate, PSZ2 G156.24+22.32, is found to be associated with a region of more than 100 galaxies within a 3 arcminutes radius around the Sunyaev-Zel'dovich maximum signal coordinates. Using 14 hours of cumulated exposure over the Sloan color filters g', r', i', and, z', we estimate the photometric redshift of these galaxies at zphot=0.29 +- 0.08. Using the red-sequence galaxy method gives a photometric red…
The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies of the cosmic microwave backgrond (CMB) at 30, 44 and 70 GHz. The thermal requirements of the LFI, and in particular the stringent limits to acceptable thermal fluctuations in the 20 K focal plane, are a critical element to achieve the instrument scientific performance. Thermal tests were carried out as part of the on-ground calibration campaign at various stages of instrument integration. In this paper we describe t…
The sky is full of variable and transient sources on all time scales, from milliseconds to decades. Planck's regular scanning strategy makes it an ideal instrument to search for variable sky signals in the millimetre and submillimetre regime, on time scales from hours to several years. A precondition is that instrumental noise and systematic effects, caused in particular by non-symmetric beam shapes, are properly removed. We present a method to perform a full sky blind search for variable and transient objects at all Planck frequencies.
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeeping data by sampling regularly the on-board sensors and registers. The housekeeping data provides information on the overall health status of the instrument and on the scientific data quality. The scienti…
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on the receivers signal is described. The experimental test setup dedicated to evaluate these effects during the instrument ground calibration is reported together with data analysis methods. Finally, main re…
70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described along with the key InP MMIC low noise amplifiers and phase switches of the units. The units were tested in specially designed cryogenic vacuum chambers capable of producing the operating conditions required for Planck radiometers, specifically, a physical temperature of 20 K for the front-end modules, 300 K for the back-end modules and 4 K for the reference…
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference sign…
In this paper we discuss the Planck-LFI in-flight calibration campaign. After a brief overview of the ground test campaigns, we describe in detail the calibration and performance verification (CPV) phase, carried out in space during and just after the cool-down of LFI. We discuss in detail the functionality verification, the tuning of the front-end and warm electronics, the preliminary performance assessment and the thermal susceptibility tests. The logic, sequence, goals and results of the in-flight tests are discussed. All the calibration activities were successfully carried out and the inst…
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). More…
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mis…
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was …
Université Paris-Saclay(巴黎萨克雷大学);CNRS(法国国家科学研究中心);Institut d’Astrophysique Spatiale(空间天体物理研究所);Laboratoire d’Océanographie Physique et Spatiale(物理与空间海洋学实验室)
In the present work, we propose a neural network based data inversion approach to reduce structured contamination sources, with a particular focus on the mapmaking for Planck High Frequency Instrument (Planck-HFI) data and the removal of large-scale systematic effects within the produced sky maps. The removal of contamination sources is rendered possible by the structured nature of these sources, which is characterized by local spatiotemporal interactions producing couplings between different spatiotemporal scales. We focus on exploring neural networks as a means of exploiting these couplings …
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft. Protons with an energy above 40MeV can penetrate the focal plane unit box causing two different effects: glitches in the raw data from direct intera…
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekeeping telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and development of the Level 1 software has followed the ESA Software Engineering Standards. A fundamental step in the software life cycle is the Verification and Validation of the software. The purpose of…
The Planck satellite detectors are calibrated in the 2015 release using the "orbital dipole", which is the time-dependent dipole generated by the Doppler effect due to the motion of the satellite around the Sun. Such an effect has also relativistic time-dependent corrections of relative magnitude 10^(-3), due to coupling with the "solar dipole" (the motion of the Sun compared to the CMB rest frame), which are included in the data calibration by the Planck collaboration. We point out that such corrections are subject to a frequency-dependent multiplicative factor. This factor differs from unity…
This thesis describes the design and implementation of several instruments for digitizing and processing analogue astronomical signals collected using radio telescopes. Modern radio telescopes have significant digital signal processing demands that are typically best met using custom processing engines implemented in Field Programmable Gate Arrays. These demands essentially stem from the ever-larger analogue bandwidths that astronomers wish to observe, resulting in large data volumes that need to be processed in real time. We focused on the development of spectrometers for enabling improved pu…
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221 Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled by the Jet Propulsion Laboratory (JPL) for the European Space Agency (ESA) Planck mission. Each refrigerator has been designed to provide a total of ~ 1W of cooling power at two instrument interfaces: they directly cool the Planck Low Frequency Instrument (LFI) around 20K while providing a pre-cooling stage for a 4 K J-T mechanical refrigerator for the High…
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI cha…
We describe the processing of data from the Low Frequency Instrument (LFI) used in production of the Planck Early Release Compact Source Catalogue (ERCSC). In particular, we discuss the steps involved in reducing the data from telemetry packets to cleaned, calibrated, time-ordered data (TOD) and frequency maps. Data are continuously calibrated using the modulation of the temperature of the cosmic microwave background radiation induced by the motion of the spacecraft. Noise properties are estimated from TOD from which the sky signal has been removed using a generalized least square map-making a…
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst" This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal and electrical conditions. For this reason tuning has been repeated several times during ground tests and it has been repeated in flight before starting nominal operations. The paper discusses the tuning …
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics. The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Tr…
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed horns each connected to the Radiometer Chain Assembly (RCA). This paper describes the design, the manufacturing and the testing of the flight model feed horns. They have been designed to optimize the LFI optical interfaces taking into account the tight mechanical requirements imposed by the Planck focal plane layout. All the eleven units have been successfully…
The HIFI data processing pipeline was developed to systematically process diagnostic, calibration and astronomical observations taken with the HIFI science instrumentas part of the Herschel mission. The HIFI pipeline processed data from all HIFI observing modes within the Herschel automated processing environment, as well as, within an interactive environment. A common software framework was developed to best support the use cases required by the instrument teams and by the general astronomers. The HIFI pipeline was built on top of that and was designed with a high degree of modularity. This m…
We compare the absolute gain photometric calibration of the Planck/HFI and Herschel/SPIRE instruments on diffuse emission. The absolute calibration of HFI and SPIRE each relies on planet flux measurements and comparison with theoretical far-infrared emission models of planetary atmospheres. We measure the photometric cross calibration between the instruments at two overlapping bands, 545 GHz / 500 $μ$m and 857 GHz / 350 $μ$m. The SPIRE maps used have been processed in the Herschel Interactive Processing Environment (Version 12) and the HFI data are from the 2015 Public Data Release 2. For our …
CUBES (Cassegrain U-Band Efficient Spectrograph) is the recently approved high-efficiency VLT spectrograph aimed to observe the sky in the UV ground-based region (305-400 nm) with a high-resolution mode (~20K) and a low-resolution mode (~5K). In this paper we will briefly describe the requirements and the design of the several software packages involved in the project, namely the instrument control software, the exposure time calculator, the end-to-end simulator, and the data reduction software suite. We will discuss how the above mentioned blocks cooperate to build up a "software ecosystem" f…
We present an analysis of the effects of beam deconvolution on noise properties in CMB measurements. The analysis is built around the artDeco beam deconvolver code. We derive a low-resolution noise covariance matrix that describes the residual noise in deconvolution products, both in harmonic and pixel space. The matrix models the residual correlated noise that remains in time-ordered data after destriping, and the effect of deconvolution on it. To validate the results, we generate noise simulations that mimic the data from the Planck LFI instrument. A $χ^2$ test for the full 70 GHz covariance…
We present three non-parametric Bayesian primordial reconstructions using Planck 2018 polarization data: linear spline primordial power spectrum reconstructions, cubic spline inflationary potential reconstructions and sharp-featured primordial power spectrum reconstructions. All three methods conditionally show hints of an oscillatory feature in the primordial power spectrum in the multipole range $\ell\sim20$ to $\ell\sim50$, which is to some extent preserved upon marginalization. We find no evidence for deviations from a pure power law across a broad observable window ($50\lesssim\ell\lesssi…
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.
We describe the spectroscopic data processing pipeline of the Dark Energy Spectroscopic Instrument (DESI), which is conducting a redshift survey of about 40 million galaxies and quasars using a purpose-built instrument on the 4-m Mayall Telescope at Kitt Peak National Observatory. The main goal of DESI is to measure with unprecedented precision the expansion history of the Universe with the Baryon Acoustic Oscillation technique and the growth rate of structure with Redshift Space Distortions. Ten spectrographs with three cameras each disperse the light from 5000 fibers onto 30 CCDs, covering t…
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy process tuned by using a set of 5 parameters Naver, r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level of distortion introduced by the onboard processing, EpsilonQ, as a func…
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometers cooled to 100 mK as planned. The settings of the readout electronics, such as the bolometer bias current, that optimize HFI's noise performance on orbit are nearly the same as the ones chosen during…
Processing of raw data from modern astronomical instruments is nowadays often carried out using dedicated software, so-called "pipelines" which are largely run in automated operation. In this paper we describe the data reduction pipeline of the Multi Unit Spectroscopic Explorer (MUSE) integral field spectrograph operated at ESO's Paranal observatory. This spectrograph is a complex machine: it records data of 1152 separate spatial elements on detectors in its 24 integral field units. Efficiently handling such data requires sophisticated software, a high degree of automation and parallelization.…
Context: Bolometers are high sensitivity detector commonly used in Infrared astronomy. The HFI instrument of the Planck satellite makes extensive use of them, but after the satellite launch two electronic related problems revealed critical. First an unexpected excess response of detectors at low optical excitation frequency for ν < 1 Hz, and secondly the Analog To digital Converter (ADC) component had been insufficiently characterized on-ground. These two problems require an exquisite knowledge of detector response. However bolometers have highly nonlinear characteristics, coming from their el…
This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 3…
The extension of on-board data processing capabilities is an attractive option to reduce telemetry for scientific instruments on deep space missions. The challenges that this presents, however, require a comprehensive software system, which operates on the limited resources a data processing unit in space allows. We implemented such a system for the Polarimetric and Helioseismic Imager (PHI) on-board the Solar Orbiter (SO) spacecraft. It ensures autonomous operation to handle long command-response times, easy changing of the processes after new lessons have been learned and meticulous book-kee…
The Stratospheric Observatory for Infrared Astronomy (SOFIA) is an airborne astronomical observatory comprised of a 2.5-meter telescope mounted in the aft section of a Boeing 747SP aircraft. During routine operations, several instruments will be available to the astronomical community including cameras and spectrographs in the near- to far-IR. Raw data obtained in-flight require a significant amount of processing to correct for background emission (from both the telescope and atmosphere), remove instrumental artifacts, correct for atmospheric absorption, and apply both wavelength and flux cali…
We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857 GHz with an angular resolution ranging from 9.9 to 4.4^2. The white noise level is around 1.5 μK degree or less in the 3 main CMB channels (100--217GHz). The photometric accuracy is better than 2% at frequencies between 100 and 353 GHz and around 7% at the two highest frequencies. The maps created…
The Planck satellite in orbit mission ended in October 2013. Between the end of Low Frequency Instrument (LFI) routine mission operations and the satellite decommissioning, a dedicated test was also performed to measure the Planck telescope emissivity. The scope of the test was twofold: (i) to provide, for the first time in flight, a direct measure of the telescope emissivity; and (ii) to evaluate the possible degradation of the emissivity by comparing data taken in flight at the end of mission with those taken during the ground telescope characterization. The emissivity was determined by heat…
Modern satellite based experiments are often very complex real-time systems, composed by flight and ground segments, that have challenging resource related constraints, in terms of size, weight, power, requirements for real-time response, fault tolerance, and specialized input/output hardware-software, and they must be certified to high levels of assurance. Hardware-software data processing systems have to be responsive to system degradation and to changes in the data acquisition modes, and actions have to be taken to change the organization of the mission operations. A big research & develop …
Calibration is a key step in the signal processing pipeline of any radio astronomical instrument. The required sky, ionospheric and instrumental models for this step can suffer from various kinds of incompleteness. In this paper we analyze several important calibration methods, ignoring for now the ionosphere. The aim is to use established statistical and signal processing tools to provide a generic method to assess calibratability of an instrument. We show how currently popular calibration techniques differ in their assumptions and also discuss their theoretical commonalities. We also study t…
The SuperAGILE (SA) instrument is a X-ray detector for As- trophysics measurements, part of the Italian AGILE satellite for X-Ray and Gamma-Ray Astronomy launched at 23/04/2007 from India. SuperAGILE is now studying the sky in the 18 - 60 KeV energy band. It is detecting sources with advanced imaging and timing detection and good spectral detection capabilities. Several astrophysical sources has been detected and localized, including Crab, Vela and GX 301-2. The instrument has the skill to resolve correctly sources in a field of view of [-40, +40] degrees interval, with the angular resolution …
Kanzelhöhe Observatory for Solar and Environmental Research (KSO) of the University of Graz (Austria) is in continuous operation since its foundation in 1943. Since the beginning its main task was the regular observation of the Sun in full disc. In this long time span covering almost seven solar cycles, a substantial amount of data was collected, which is made available online. In this paper we describe the separate processing steps from data acquisition to high level products for the different observing wavelengths. First of all we work out in detail the quality classification, which is impor…
The CIWS-FW is aimed at providing a common and standard solution for the storage, processing and quick look at the data acquired from scientific instruments for astrophysics. The target system is the instrument workstation either in the context of the Electrical Ground Support Equipment for space-borne experiments, or in the context of the data acquisition system for instrumentation. The CIWS-FW core includes software developed by team members for previous experiments and provides new components and tools that improve the software reusability, configurability and extensibility attributes. The …
We present the data processing pipeline to generate calibrated data products from the Spectral and Photometric Imaging Receiver (SPIRE) imaging Fourier Transform Spectrometer on the Herschel Space Observatory. The pipeline processes telemetry from SPIRE observations and produces calibrated spectra for all resolution modes. The spectrometer pipeline shares some elements with the SPIRE photometer pipeline, including the conversion of telemetry packets into data timelines and calculation of bolometer voltages. We present the following fundamental processing steps unique to the spectrometer: tempo…
After the focal plane of the HFI instrument of the Planck mission (launched in May 2009) reached its operational temperature, we observed thermal signatures of interactions of cosmic rays with the Planck satellite, located at the L2 Lagrange point. When a particle hits a component of the bolometers (e.g. thermometer, grid or wafer) mounted on the focal plane of HFI, a thermal spike (called glitch) due to energy deposition is measured. Processing these data revealed another effect due to particle showers of high energy cosmic rays: High Coincidence Events (HCE), composed of glitches occurring c…
{Context}. The HIFI instrument on the Herschel Space Observatory performed over 9100 astronomical observations, almost 900 of which were calibration observations in the course of the nearly four-year Herschel mission. The data from each observation had to be converted from raw telemetry into calibrated products and were included in the Herschel Science Archive. {Aims}. The HIFI pipeline was designed to provide robust conversion from raw telemetry into calibrated data throughout all phases of the HIFI missions. Pre-launch laboratory testing was supported as were routine mission operations. {Met…