Planck pre-launch status: High Frequency Instrument polarization calibration

C. Rosset, M. Tristram, N. Ponthieu, P. Ade, A. Catalano, L. Conversi, F. Couchot, B. P. Crill, F. -X. Désert, K. Ganga, M. Giard, Y. Giraud-Héraud, J. Haïssins… 展开作者

C. Rosset, M. Tristram, N. Ponthieu, P. Ade, A. Catalano, L. Conversi, F. Couchot, B. P. Crill, F. -X. Désert, K. Ganga, M. Giard, Y. Giraud-Héraud, J. Haïssinski, S. Henrot-Versillé, W. Holmes, W. C. Jones, J. -M. Lamarre, A. Lange, C. Leroy, J. Macías-Pérez, B. Maffei, P. de Marcillac, M. -A. Miville-Deschênes, L. Montier, F. Noviello, F. Pajot, O. Perdereau, F. Piacentini, M. Piat, S. Plaszczynski, E. Pointecouteau, J. -L. Puget, I. Ristorcelli, G. Savini, R. Sudiwala, M. Veneziani, D. Yvon

摘要:

普朗克的高频仪器将在100至857 GHz的毫米和亚毫米域中绘制整个天空,在100、143、217和353 GHz具有前所未有的偏振灵敏度($ΔP/T_{\tiny cmb} \sim 4\cdot 10^{-6}$)。它将导致我们对宇宙微波背景各向异性和极化前景信号的理解的重大改进。普朗克将对$E$模谱进行高分辨率测量(高达$\ell \sim 1500$),并将在寻找原始引力波对CMB偏振的微弱印记方面发挥突出作用。本文讨论了温度(增益)和偏振(偏振效率和探测器方向)的校准对偏振测量的影响。仪器的偏振参数的具体要求的设置,我们报告他们的飞行前测量HFI测辐射热计。我们提出了一个半分析的方法,准确地占仪器的扫描策略,以及不同的检测器的组合。我们使用这种方法来传播误差通过的CMB角功率谱在特定情况下的普朗克-HFI,并推导出偏振参数的约束。我们表明,为了将系统误差限制在$E$模功率谱宇宙方差的10%以内,增益、偏振效率和探测器方位的不确定度必须分别低于0.15%、0.3%和1°。本文报道的发射前地面测量已经满足了这些要求。

英文摘要:

The High Frequency Instrument of Planck will map the entire sky in the millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented sensitivity to polarization ($ΔP/T_{\tiny cmb} \sim 4\cdot 10^{-6}$) at 100, 143, 217 and 353 GHz. It will lead to major improvements in our understanding of the Cosmic Microwave Background anisotropies and polarized foreground signals. Planck will make high resolution measurements of the $E$-mode spectrum (up to $\ell \sim 1500$) and will also play a prominent role in the search for the faint imprint of primordial gravitational waves on the CMB polarization. This paper addresses the effects of calibration of both temperature (gain) and polarization (polarization efficiency and detector orientation) on polarization measurements. The specific requirements on the polarization parameters of the instrument are set and we report on their pre-flight measurement on HFI bolometers. We present a semi-analytical method that exactly accounts for the scanning strategy of the instrument as well as the combination of different detectors. We use this method to propagate errors through to the CMB angular power spectra in the particular case of Planck-HFI, and to derive constraints on polarization parameters. We show that in order to limit the systematic error to 10% of the cosmic variance of the $E$-mode power spectrum, uncertainties in gain, polarization efficiency and detector orientation must be below 0.15%, 0.3% and 1° respectively. Pre-launch ground measurements reported in this paper already fulfill these requirements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑