Planck/LFI星载数据处理的优化

Optimization of Planck/LFI on--board data handling

M. Maris, M. Tomasi, S. Galeotta, M. Miccolis, S. Hildebrandt, M. Frailis, R. Rohlfs, N. Morisset, A. Zacchei, M. Bersanelli, P. Binko, C. Burigana, R. C. Butle… 展开作者

M. Maris, M. Tomasi, S. Galeotta, M. Miccolis, S. Hildebrandt, M. Frailis, R. Rohlfs, N. Morisset, A. Zacchei, M. Bersanelli, P. Binko, C. Burigana, R. C. Butler, F. Cuttaia, H. Chulani, O. D'Arcangelo, S. Fogliani, E. Franceschi, F. Gasparo, F. Gomez, A. Gregorio, J. M. Herreros, R. Leonardi, P. Leutenegger, G. Maggio, D. Maino, M. Malaspina, N. Mandolesi, P. Manzato, M. Meharga, P. Meinhold, A. Mennella, F. Pasian, F. Perrotta, R. Rebolo, M. Turler, A. Zonca

摘要:

为了评估对1/f噪声的稳定性,普朗克任务机载低频仪器(LFI)将以远高于其遥测带宽35.5 kbps所允许的数据速率的速率获取数据。数据由机载管道处理,然后在地面上进行反向步骤。本文阐述了LFI的科学星上处理,以适应允许的数据速率。这是一个有损过程,通过对44个LFI检测器中的每一个使用一组5个参数Naver、r1、r2、q、O进行调谐。本文量化了由板载处理引入的失真水平,EpsilonQ,作为这些参数的函数。它描述了优化机载处理链的方法。调整程序基于应用于未处理和未压缩原始数据的优化算法,这些原始数据由模拟、发射前测试或从诊断模式下的LFI操作中获取的数据提供。所有需要的优化步骤都由自动化工具OCA 2执行,该工具以优化的参数结束并产生一组统计指标,其中包括压缩率Cr和EpsilonQ。对于Planck/LFI,要求是Cr = 2.4和ε Q <=仪器白噪声均方根的10%。为了加速该过程,开发了一种分析模型,该模型能够提取关于ε Q和Cr的大部分相关信息作为信号统计和处理参数的函数。该模型将用于仪器数据分析。该方法应用于地面试验期间,当仪器在代表飞行的条件下工作时。通过优化参数和性能验证,达到了35.5Kbps的数据传输速率,同时使EpsilonQ保持在3.8%的白噪声均方根值,满足要求。

英文摘要:

To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy process tuned by using a set of 5 parameters Naver, r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level of distortion introduced by the onboard processing, EpsilonQ, as a function of these parameters. It describes the method of optimizing the onboard processing chain. The tuning procedure is based on a optimization algorithm applied to unprocessed and uncompressed raw data provided either by simulations, prelaunch tests or data taken from LFI operating in diagnostic mode. All the needed optimization steps are performed by an automated tool, OCA2, which ends with optimized parameters and produces a set of statistical indicators, among them the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr = 2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup the process an analytical model is developed that is able to extract most of the relevant information on EpsilonQ and Cr as a function of the signal statistics and the processing parameters. This model will be of interest for the instrument data analysis. The method was applied during ground tests when the instrument was operating in conditions representative of flight. Optimized parameters were obtained and the performance has been verified, the required data rate of 35.5 Kbps has been achieved while keeping EpsilonQ at a level of 3.8% of white noise rms well within the requirements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑