摘要:

在核物理和中子物理的许多实验中,超导磁谱仪的杂散磁场会对其他实验产生潜在的影响。延迟谱仪aSPECT尤其由超导磁体系统组成,该超导磁体系统产生高达6.2T的强纵向磁场。为了不干扰aSPECT附近的其他实验,我们必须为磁体系统开发一个磁场返回轭。当回磁轭必须减少杂散磁场时,内部磁场及其均匀性不应受到影响。在许多情况下,用于aSPECT的磁屏蔽必须以有限的空间进行管理。此外,我们必须确保磁体线圈上的附加磁力不具有破坏性。为了确定用于aSPECT的磁屏蔽的最合适的几何形状,我们模拟了各种可能的几何形状和非线性磁导率的屏蔽材料的组合。通过霍尔和核磁共振探头的磁场测量,我们的模拟结果进行了检查。实验数据与模拟值吻合较好:与模拟外磁场的平均偏差为(-1.7+/-4.8)%。然而,在两个临界区域,内部磁场偏离模拟值分别为0.2%<1 E-4。

英文摘要:

Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2T. In order not to disturb other experiments in the vicinity of aSPECT, we had to develop a magnetic field return yoke for the magnet system. While the return yoke must reduce the stray magnetic field, the internal magnetic field and its homogeneity should not be affected. As in many cases, the magnetic shielding for aSPECT must manage with limited space. In addition, we must ensure that the additional magnetic forces on the magnet coils are not destructive. In order to determine the most suitable geometry for the magnetic shielding for aSPECT, we simulated a variety of possible geometries and combinations of shielding materials of non-linear permeability. The results of our simulations were checked through magnetic field measurements both with Hall and nuclear magnetic resonance probes. The experimental data are in good agreement with the simulated values: The mean deviation from the simulated exterior magnetic field is (-1.7+/-4.8)%. However, in the two critical regions, the internal magnetic field deviates by 0.2% respectively <1E-4 from the simulated values.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑