We report a surface treatment that systematically improves the quality factor of niobium radio frequency cavities beyond the expected limit for niobium. A combination of annealing in a partial pressure of nitrogen or argon gas and subsequent electropolishing of the niobium cavity surface leads to unprecedented low values of the microwave surface resistance, and an improvement in the efficiency of the accelerating structures up to a factor of 3, reducing the cryogenic load of superconducting cavities for both pulsed and continuous duty cycles. The field dependence of the surface resistance is reversed compared to standardly treated niobium.
Experimental data on N-doped superconducting (sc) cavities are further analyzed which contribute to confirm a recently proposed model explaining the increase of the Q-value versus the accelerating gradient.
A deeply modulated, regular, continuous, oscillating current waveform is reliably and repeatably achieved during electropolishing of niobium single-cell elliptical radiofrequency cavities. Details of the technique and cavity test results are reported here. The method is applicable for cavity frequencies in the range 500 MHz to 3.9 GHz and can be extended to multicell structures.
First, this is a response to a criticism I have received about the paper which is mentioned in the title. Second, the aim is to show the important role of small (compared to coherence length) weak superconducting spots when located at the surface in connection with the proximity and percolation effects.
As a result of a collaboration between Jefferson Lab and niobium manufacturer CBMM, ingot niobium was explored as a possible material for superconducting radiofrequency (SRF) cavity fabrication. The first single cell cavity from large grain high purity niobium was fabricated and successfully tested at Jefferson Lab in 2004. This pioneering work triggered research activities in other SRF laboratories around the world. Large grain niobium became not only an interesting alternative material for cavity builders, but also material scientists and surface scientists were eager to participate in the d…
An increase in the quality factor of superconducting radiofrequency cavities is achieved by minimizing the surface resistance during processing steps. The surface resistance is the sum of temperature independent residual resistance and temperature/material dependent Bardeen-Cooper-Schrieffer (BCS) resistance. High temperature heat treatment usually reduces the impurities concentration from the bulk niobium, lowering the residual resistance. The BCS part can be reduced by selectively doping non-magnetic impurities. The increase in quality factor, termed as Q-rise, was observed in cavities when …
The Q-factor of superconducting accelerating cavities can be substantially improved by a special heat treatment under N2 atmosphere (N-doping). Recent experiments at Fermi National Laboratory investigated the dependence of Q on the RF frequency and showed, unexpectedly, both an increase and a decrease with the RF field amplitude. This paper shall explain this finding by extending a previously proposed model founded on the two fluid model of RF losses, percolation and the proximity effect in a disordered composite.
The surface resistance Rs of superconducting cavities prepared by sputter coating a thin niobium film on a copper substrate increases significantly stronger with the applied RF field compared to cavities of bulk material. A possible cause is that due to the thermal boundary resistance between the copper substrate and the niobium film Rs is enhanced due to global heating of the inner cavity wall. Introducing helium gas in the cavity and measuring its pressure as a function of applied field allowed to conclude that the inner surface of the cavity is heated up by only 60+/-60 mK when Rs increases…
The dependence of the Q-value on the RF field (Q-slope) is actively studied in various accelerator laboratories. Although remedies against this dependence have been found, the physical cause still remains obscure. A rather straightforward two-fluid model description of the Q-slope in the low and high field domains is presented with emphasis on the recently experimentally identified improvement of the Q-value by so-called "N-doping".
In a recent publication [Appl. Phys. Lett. 104, 092601 (2014)] Ciovati et al. claim that: 1) thermal effects were disregarded in our original work [*]; 2) increase of $Q$ at $T=2$ K up to about $B\sim$100 mT in nitrogen doped cavities is just an extended low field $Q$ slope observed in non-doped cavities, which is furthermore attributed to the decrease of the "BCS" component of surface resistance. Here we show that both claims are wrong and the conclusions of Ciovati et al. are incorrect. [*] A. Romanenko and A. Grassellino, Appl. Phys. Lett. 102, 252603 (2013)
In a recent comment [arXiv:1405.2978v1 (2014)] Romanenko and Grassellino made unsubstantiated statements about our work [Appl. Phys. Lett. 104, 092601 (2014)] and ascribed to us wrong points which we had not made. Here we show that the claims of Romanenko and Grassellino are based on misinterpretation of our Letter and inadequate data analysis in their earlier work [*]. [*] A. Romanenko and A. Grassellino, Appl. Phys. Lett. 102, 252603 (2013)
The improvement of the quality factor Q0 of superconducting radio-frequency (SRF) cavities at medium accelerating gradients (20-25 MV/m) is important in order to reduce the cryogenic losses in continuous wave (CW) accelerators used for a variety of applications. In recent years, SRF cavities fabricated from ingot niobium have become a viable alternative to standard high-purity fine-grain Nb for the fabrication of high-performing SRF cavities with the possibility of significant cost reduction. Recent studies demonstrated the improvement of Q0 at medium field in cavities heat treated at 800-1200…
The PIP II linear accelerator includes different types of niobium SRF cavities including 650 MHz elliptical low (0.61) and high (0.92) beta cavities. The elliptical cavity surface is processed with the electropolishing method. The elliptical cavities especially the low-$β$ 650 MHz cavities showed a rough equator surface after the EP was per-formed with the standard EP conditions. This work was focused to study the effect of different EP parameters, including cathode surface area, temperature and voltage, and optimize them to improve the cavity surface.
Trapped magnetic flux is known to be a significant contribution to the residual resistance of superconducting radio frequency (SRF) cavities. The additional losses depend strongly if the vortices are depinned by the RF. The depinning is affected by the purity of the material, and the size of the pinning centers, as well as the cavity operation frequency. One may define a depinning frequency, above which significant depinning occurs. This publication presents a derivation of the depinning frequency from experimental data. We find a depinning frequency of 673 MHz for RRR 110 niobium. On this bas…
In this paper we present the discovery of a new surface treatment applied to superconducting radio frequency (SRF) niobium cavities, leading to unprecedented accelerating fields of 49 MV/m in TESLA-shaped cavities, in continuous wave (CW); the corresponding peak magnetic fields are the highest ever measured in CW, about 210 mT. For TESLA-shape cavities the maximum quench field ever achieved was ~45 MV/m - reached very rarely- with most typical values being below 40 MV/m. These values are reached for niobium surfaces treated with electropolishing followed by the so called mild bake, a 120C vacu…
Cool-down dynamics of superconducting accelerating cavities became particularly important for obtaining very high quality factors in SRF cavities. Previous studies proved that when cavity is cooled fast, the quality factor is higher than when cavity is cooled slowly. This has been discovered to derive from the fact that a fast cool-down allows better magnetic field expulsion during the superconducting transition. In this paper we describe the first experiment where the temperature all around the cavity was mapped during the cavity cool-down through transition temperature, proving the existence…
We present results on the effects of interstitial oxygen and carbon on a bulk-niobium superconducting radio-frequency cavity. Previous experiments have shown that high-temperature (~800 $^\circ\text{C}$) nitrogen-doping plays the dominant role in the reduction of the electron mean free path in the RF penetration layer of niobium that leads to a decrease in microwave surface resistance and a suppression the temperature-dependent component of the surface resistance with increasing accelerating gradient. In this work, we show that oxygen and carbon-doping has very similar effects on cavity perfor…
Many modern and proposed future particle accelerators rely on superconducting radio frequency cavities made of bulk niobium as primary particle accelerating structures. Such cavities suffer from the anomalous field dependence of their quality factors Q0. High field degradation - so-called high field Q-slope - is yet unexplained even though an empirical cure is known. Here we propose a mechanism based on the presence of proximity-coupled niobium hydrides, which can explain this effect. Furthermore, the same mechanism can be present in any surface-sensitive experiments or superconducting devices…
SRF niobium cavities are the building blocks of modern accelerators for scientific applications. Lower surface resistance, higher fields, and high operating temperatures advance the reach of the future accelerators for scientific discovery as well as potentially enabling cost-effective industrial solutions. We describe the design and performance of an Nb$_{3}$Sn coating system that converts the inner surface of niobium cavities to Nb$_{3}$Sn film. Niobium surface, heated by radiation from the niobium retort, is exposed to Sn and SnCl$_{2}$ vapor during the heat cycle, which results in about 2 …
Ambient magnetic field, if trapped in the penetration depth, leads to the residual resistance and therefore sets the limit for the achievable quality factors in superconducting niobium resonators for particle accelerators. Here we show that a complete expulsion of the magnetic flux can be performed and leads to: 1) record quality factors $Q > 2\times10^{11}$ up to accelerating gradient of 22 MV/m; 2) $Q\sim3\times10^{10}$ at 2 K and 16 MV/m in up to 190 mG magnetic fields. This is achieved by large thermal gradients at the normal/superconducting phase front during the cooldown. Our findings op…
Expulsion of ambient flux has been shown to be crucial to obtain high quality factors in bulk niobium SRF cavities. However, there remain many questions as to what properties of the niobium material determine its flux expulsion behavior. In this paper, we present first results from a new study of two cavities that were specially fabricated to study flux expulsion. Both cavities were made from large grain ingot niobium slices, one of which had its slices rolled prior to fabrication, and none these slices were annealed prior to measurement. Expulsion measurements indicate that a dense network of…
Long standing data from niobium thin film accelerating cavities will be revisited and analysed by a modified London model of RF superconductivity. Firstly, the applicability of this model is explored using data of the BCS surface resistance and its dependence on the RF magnetic field, temperature and mean free path. Secondly, the RF losses from trapped magnetic flux are analysed with regard to their dependence on these same parameters.
We investigate the effect of high temperature treatments followed by only high-pressure water rinse (HPR) of superconducting radio frequency (SRF) niobium cavities. The objective is to provide a cost effective alternative to the typical cavity processing sequence, by eliminating the material removal step post furnace treatment while preserving or improving the RF performance. The studies have been conducted in the temperature range 800-1000C for different conditions of the starting substrate: large grain and fine grain, electro-polished (EP) and centrifugal barrel polished (CBP) to mirror fini…
Titanium and niobium are the main materials used for the fabrication of Superconducting Radio Frequency (SRF) cavities. These two metals are usually joined , using various welding techniques, using a third material in between. This contribution focuses on the development of an innovative electron beam welding technique capable of producing a strong bond between these two different materials. Several samples are produced and tested to assess the mechanical strength at room and cryogenic temperature as well as the composition of the resulting welded joint. Also, the first units of the Single Spo…
Superconducting niobium film cavities deposited on copper substrates (Nb/Cu) have suffered from strong field-dependent surface resistance, often referred to as the Q-slope problem, since their invention. We argue that the Q-slope may not be an intrinsic problem, but rather originates from a combination of factors which can be revealed in appropriate environmental conditions. In this study, extrinsic effects were carefully minimized in a series of experiments on a seamless cavity. The origin of the Q-slope in low frequency cavities is traced back to two contributions with different temperature …
Nitrogen doping treatment with the subsequent electropolishing (EP) of the niobium superconducting cavity can significantly increase the cavity's quality factor up to a factor of 3. But the process of the EP removal may reintroduce hydrogen in the cavity surface, which may influence the cavity's radio frequency performance. Plasma cleaning study on niobium samples with gas mixtures of argon and oxgen intended to remove contaminations (hydrocarbons and micronicdust particles) from cavity surface to avoid field emission, was performed in Peking University. The niobium samples have been analyzed …
Future particle accelerators such as the the SLAC ``Linac Coherent Light Source-II'' (LCLS-II) and the proposed Cornell Energy Recovery Linac (ERL) require hundreds of superconducting radio-frequency (SRF) cavities operating in continuous wave (CW) mode. In order to achieve economic feasibility of projects such as these, the cavities must achieve a very high intrinsic quality factor ($Q_0$) to keep cryogenic losses within feasible limits. To reach these high $Q_0$'s in the case of LCLS-II, nitrogen-doping has been proposed as a cavity preparation technique. When dealing with $Q_0$'s greater th…
Nanoscale defect structure within the magnetic penetration depth of ~100nm is key to the performance limitations of niobium superconducting radio frequency (SRF) cavities. Using a unique combination of advanced thermometry during cavity RF measurements, and TEM structural and compositional characterization of the samples extracted from cavity walls, we discover the existence of nanoscale hydrides in electropolished cavities limited by the high field Q slope, and show the decreased hydride formation in the electropolished cavity after 120C baking. Furthermore, we demonstrate that adding 800C hy…
The first heavy ion accelerator is being constructed by the rare isotope science project (RISP) launched by the Institute of Basic Science (IBS) in South Korea. Four different types of superconducting cavities were designed, and prototypes were fabricated such as a quarter wave resonator (QWR), a half wave resonator (HWR) and a single spoke resonator (SSR). One of the critical factors determining performances of the superconducting cavities is a residual resistance ratio (RRR). The RRR values essentially represent how much niobium is pure and how fast niobium can transmit heat as well. In gene…
In niobium superconducting radio frequency (SRF) accelerating cavities a decrease of the quality factor at lower fields - a so called \emph{low field Q slope or LFQS} - has been a long-standing unexplained effect. By extending the high $Q$ measurement techniques to ultralow fields we discover two previously unknown features of the effect: i) saturation at rf fields lower than $E_\mathrm{acc} \sim 0.1$~MV/m; ii) strong degradation enhancement by growing thicker niobium pentoxide. Our findings suggest that the LFQS may be caused by the two level systems in the natural niobium oxide on the inner …
The radio-frequency surface resistance of niobium resonators is incredibly reduced when nitrogen impurities are dissolved as interstitial in the material, conferring ultra-high Q-factors at medium values of accelerating field. This effect has been observed in both high and low temperature nitrogen treatments. As a matter of fact, the peculiar anti Q-slope observed in nitrogen doped cavities, i.e. the decreasing of the Q-factor with the increasing of the radio-frequency field, come from the decreasing of the BCS surface resistance component as a function of the field. Such peculiar behavior has…
We propose a model to explain power dissipation leading to the formation of hot spots in the inner walls of niobium thin film superconducting RF cavities. The physical mechanism that we explore is due to the constriction of surface electrical current flow at grain interface boundaries. This constriction creates an additional electrical contact resistance which induces localized punctual heat dissipation. The temperature at these spots is derived; and the electrical contact resistance is shown to depend on the magnetic field, on the gain contact size over which dissipation occurs, and on other …
The proposed linear electron-positron collider TESLA is based on 1.3 GHz superconducting niobium cavities for particle acceleration. For a centre-of-mass energy of 500 GeV, an accelerating field of 23.4 MV/m is required which is reliably achieved with a niobium surface preparation by chemical etching. An upgrade of the collider to 800 GeV requires an improved cavity preparation technique. In this paper, results are presented on single-cell cavities which demonstrate that fields of up to 40 MV/m are accessible by electrolytic polishing of the inner surface of the cavity.
We present the results of from DC magnetization and penetration depth measurements of cylindrical bulk large-grain (LG) and fine-grain (FG) niobium samples used for the fabrication of superconducting radio frequency (SRF) cavities. The surface treatment consisted of electropolishing and low temperature baking as they are typically applied to SRF cavities. The magnetization data were fitted using a modified critical state model. The critical current density Jc and pinning force Fp are calculated from the magnetization data and their temperature dependence and field dependence are presented. The…
A systematic study is presented on the superconductivity (sc) parameters of the ultrapure niobium used for the fabrication of the nine-cell 1.3 GHz cavities for the linear collider project TESLA. Cylindrical Nb samples have been subjected to the same surface treatments that are applied to the TESLA cavities: buffered chemical polishing (BCP), electrolytic polishing (EP), low-temperature bakeout (LTB). The magnetization curves and the complex magnetic susceptibility have been measured over a wide range of temperatures and dc magnetic fields, and also for di erent frequencies of the applied ac m…
Superconducting radio frequency (SRF) cavities made from niobium and cooled with liquid helium are becoming key components of many particle accelerators. The helium vessels surrounding the RF cavities, portions of the niobium cavities themselves, and also possibly the vacuum vessels containing these assemblies, generally fall under the scope of local and national pressure vessel codes. In the U.S., Department of Energy rules require national laboratories to follow national consensus pressure vessel standards or to show "a level of safety greater than or equal to" that of the applicable standar…
We report the finding of new surface treatments that permit to manipulate the niobium resonator nitrogen content in the first few nanometers in a controlled way, and the resonator fundamental Mattis-Bardeen surface resistance and residual resistance accordingly. In particular, we find surface infusion conditions that systematically a) increase the quality factor of these 1.3 GHz superconducting radio frequency (SRF) bulk niobium resonators, up to very high gradients; b) increase the achievable accelerating gradient of the cavity compared to its own baseline with state-of-the-art surface proces…
Magnetic flux trapped during the cooldown of superconducting radio-frequency cavities through the transition temperature due to incomplete Meissner state is known to be a significant source of radio-frequency losses. The sensitivity of flux trapping depends on the distribution and the type of defects and impurities which pin vortices, as well as the cooldown dynamics when the cavity transitions from a normal to superconducting state. Here we present the results of measurements of the flux trapping sensitivity on 1.3 GHz elliptical cavities made from large-grain niobium with different purity fo…
Identifying the loss mechanisms of niobium film cavities enables an accurate determination of applications for future accelerator projects and points to research topics required to mitigate their limitations. Measurements on samples show that the electric field is a dominant loss mechanism for niobium films, acting through interface tunneling between localized states in surface oxides and delocalized states in the superconducting niobium.
The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of Eacc >= 25 MV/m at a quality factor Q0 > 5E+9. The design goal for the cavities of the TESLA Test Facility (TTF) linac was set to the more moderate value of Eacc >= 15 MV/m. In a first series of 27 industrially produced TTF cavities the average gradient at Q0 = 5E+9 was measured to be 20.1 +- 6.2 MV/m, excluding a few cavities suffering from serious fabrication or material defects. In the second production of 24 TTF cavitie…
An apparatus and a method are described for plasma etching of the inner surface of superconducting radio frequency (SRF) cavities. Accelerator SRF cavities are formed into a variable-diameter cylindrical structure made of bulk niobium, for resonant generation of the particle accelerating field. The etch rate non-uniformity due to depletion of the radicals has been overcome by the simultaneous movement of the gas flow inlet and the inner electrode. An effective shape of the inner electrode to reduce the plasma asymmetry for the coaxial cylindrical rf plasma reactor is determined and implemented…
We report a strong effect of the cooling dynamics through $T_\mathrm{c}$ on the amount of trapped external magnetic flux in superconducting niobium cavities. The effect is similar for fine grain and single crystal niobium and all surface treatments including electropolishing with and without 120$^\circ$C baking and nitrogen doping. Direct magnetic field measurements on the cavity walls show that the effect stems from changes in the flux trapping efficiency: slow cooling leads to almost complete flux trapping and higher residual resistance while fast cooling leads to the much more efficient flu…