我们提出了一种核医学成像技术,采用从β ^+ -γ符合的三重γ轨迹相交,能够达到亚毫米空间分辨率的3维与减少的要求,重建每个体素的交叉相比,传统的PET重建分析。这种“$γ$ -PET”技术利用特定的β ^+衰变同位素,同时发射出额外的光子。利用正电子湮没和第三光子之间的三重符合,可以将重建的“真实”事件与背景分离。为了表征这种技术,已经进行了蒙特卡罗模拟和图像重建。已发现可实现的空间分辨率达到ca。0.4 mm(FWHM),用于22 Na点源的可视化。只有40个交叉点足以对嵌入在大约1 mm^3的体素体积内的水的散射体积中的点源进行可靠的亚毫米图像重建(“高分辨率模式”)。此外,从400 MBq的^76Br注入活度开始,在2 x 2 x 3 mm^3的较大体素体积(“高灵敏度模式”)的情况下,仅需要大约40个重建交叉点的相同数量。需要这样低数量的重建事件显著地减少了图像重建所需的采集时间(在上述情况下为大约140秒),并且因此可以打开准实时成像的前景。
英文摘要:
We present a nuclear medical imaging technique, employing triple-gamma trajectory intersections from beta^+ - gamma coincidences, able to reach sub-millimeter spatial resolution in 3 dimensions with a reduced requirement of reconstructed intersections per voxel compared to a conventional PET reconstruction analysis. This '$γ$-PET' technique draws on specific beta^+ - decaying isotopes, simultaneously emitting an additional photon. Exploiting the triple coincidence between the positron annihilation and the third photon, it is possible to separate the reconstructed 'true' events from background. In order to characterize this technique, Monte-Carlo simulations and image reconstructions have been performed. The achievable spatial resolution has been found to reach ca. 0.4 mm (FWHM) in each direction for the visualization of a 22Na point source. Only 40 intersections are sufficient for a reliable sub-millimeter image reconstruction of a point source embedded in a scattering volume of water inside a voxel volume of about 1 mm^3 ('high-resolution mode'). Moreover, starting with an injected activity of 400 MBq for ^76Br, the same number of only about 40 reconstructed intersections are needed in case of a larger voxel volume of 2 x 2 x 3~mm^3 ('high-sensitivity mode'). Requiring such a low number of reconstructed events significantly reduces the required acquisition time for image reconstruction (in the above case to about 140 s) and thus may open up the perspective for a quasi real-time imaging.
Three-Photon Bayesian Imaging of Ortho-Positronium
National Centre for Nuclear Research(国家核研究中心);INSA-Lyon(里昂国立应用科学学院);Université Claude Bernard Lyon 1(里昂第一大学(克洛德·贝尔纳大学));CNRS(法国国家科学研究中心);Inserm(法国国家健康与医学研究院);IT:U Interdisciplinary Transformation University(IT:U跨学科转型大学);University of Vienna(维也纳大学)
108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations
Central Research Laboratory, Hamamatsu Photonics K. K.(滨松光子株式会社中央研究实验室)
Roadmap Towards Quantum Entanglement Positron Emission Tomography (QE-PET)
Institute of Physics, Jagiellonian University(雅盖隆大学物理研究所);Center for Theranostics, Jagiellonian University(雅盖隆大学诊疗中心);University of California Santa Cruz(加州大学圣克鲁兹分校);Indian Institute of Technology Bombay(印度理工学院孟买分校);The University of Tokyo(东京大学);Institute for Medical Research and Occupational Health, Division of Radiation Protection(医学研究与职业健康研究所辐射防护部);University of Sydney(悉尼大学);University of Zagreb Faculty of Science, Department of Physics(萨格勒布大学理学院物理系);ICTP South American Institute for Fundamental Research(ICTP南美基础研究所);Universidade Federal de São Paulo(圣保罗联邦大学);Instituto de Fisica Corpuscular (IFIC), CSIC-UV(粒子物理研究所(IFIC),西班牙国家研究委员会-瓦伦西亚大学);University of Illinois Urbana–Champaign(伊利诺伊大学厄巴纳-香槟分校);National Institutes for Quantum Science and Technology(国立量子科学技术研究院);Institute of Science Tokyo(东京科学研究所)
Machine Learning-Based Inter-Crystal Scatter Recovery for Ultra-High Resolution PET Imaging
Université de Sherbrooke(谢布鲁克大学);Interdisciplinary Institute for Technological Innovation(跨学科技术创新研究所);Sherbrooke Molecular Imaging Center of CRCHUS(CRCHUS谢布鲁克分子成像中心);Institut Fresnel(弗雷内尔研究所);Aix Marseille Univ(艾克斯-马赛大学);Centrale Med(中央医学院);Imaging Research & Technology (IR&T) Inc.(成像研究与技术公司)
CRYSP: a Total-Body PET based on cryogenic cesium iodide crystals
Donostia International Physics Center(多诺斯蒂亚国际物理中心);Ikerbasque (Basque Foundation for Science)(伊克拉巴斯基(巴斯克科学基金会));Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València(分子成像仪器研究所(I3M),CSIC-瓦伦西亚理工大学联合中心);Universidad del País Vasco (UPV/EHU)(巴斯克大学);Instituto de Física Corpuscular (IFIC), CSIC & Universitat de València(粒子物理研究所(IFIC),CSIC与瓦伦西亚大学)
Fast full-body reconstruction for a functional human RPC-PET imaging system using list-mode simulated data and its applicability to radiation oncology and radiology