arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1203.5401cond-mat.mtrl-sci
收藏

原子分辨率Kelvin探针力显微镜的多尺度模拟

A Multi-scale Approach for Simulations of Kelvin Probe Force Microscopy with Atomic Resolution

Ali Sadeghi, Alexis Baratoff, S. Alireza Ghasemi, Stefan Goedecker, Thilo Glatzel, Shigeki Kawai, Ernst Meyer

摘要:

距离依赖性和原子尺度的对比度观察到标称接触电势差(CPD)信号记录的绝缘和半导体样品的表面上,刺激理论试图解释这种影响。我们分两步解决这个问题。首先,在可调非均匀网格上用有限差分法处理宏观针尖-悬臂梁-样品系统的静电问题。然后将尖端尖端下的电场插入到一系列基于原子小波的密度泛函理论(DFT)计算中。结果显示了一个现实的中性,但反应性硅纳米级尖端与NaCl(001)样品相互作用。偏置相关的力和由此产生的原子位移计算到前所未有的精度。振幅调制(AM)和频率调制(FM)KPFM信号和相应的本地接触电势差(LCPD)的理论表达式通过结合宏观和原子贡献的静电力分量产生的电压调制频率,并评估几个尖端振荡幅度A高达10 nm。原子力相对于偏压的斜率在几伏特内基本恒定,是决定原子尺度LCPD对比度变化的基本量。已经高于A = 0.1 nm,两种模式下的LCPD对比度表现出与斜率几乎相同的空间依赖性。在AM模式中,该对比度与$A^{-1/2}$近似成比例,但仍然比FM模式中的对比度弱得多,FM模式中的对比度随着A的增加而下降得更快。这些趋势是宏观贡献的KPFM信号,这是更强的AM模式,特别重要的是,如果样品是一个绝缘体,即使在亚纳米分离的原子尺度的对比度出现的结果。

英文摘要:

The distance dependence and atomic-scale contrast observed in nominal contact potential difference (CPD) signals recorded by KPFM on surfaces of insulating and semiconducting samples, have stimulated theoretical attempts to explain such effects. We attack this problem in two steps. First, the electrostatics of the macroscopic tip-cantilever-sample system is treated by a finite-difference method on an adjustable nonuniform mesh. Then the resulting electric field under the tip apex is inserted into a series of atomistic wavelet-based density functional theory (DFT) calculations. Results are shown for a realistic neutral but reactive silicon nano-scale tip interacting with a NaCl(001) sample. Bias-dependent forces and resulting atomic displacements are computed to within an unprecedented accuracy. Theoretical expressions for amplitude modulation (AM) and frequency modulation (FM) KPFM signals and for the corresponding local contact potential differences (LCPD) are obtained by combining the macroscopic and atomistic contributions to the electrostatic force component generated at the voltage modulation frequency, and evaluated for several tip oscillation amplitudes A up to 10 nm. Being essentially constant over a few Volts, the slope of atomistic force versus bias is the basic quantity which determines variations of the atomic-scale LCPD contrast. Already above A = 0.1 nm, the LCPD contrasts in both modes exhibit almost the same spatial dependence as the slope. In the AM mode, this contrast is approximately proportional to $A^{-1/2}$, but remains much weaker than the contrast in the FM mode, which drops somewhat faster as A is increased. These trends are a consequence of the macroscopic contributions to the KPFM signal, which are stronger in the AM-mode and especially important if the sample is an insulator even at sub-nanometer separations where atomic-scale contrast appears.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑