K. Inami, T. Mori, T. Matsumura, K. Kurimoto, S. Hasegawa, Y. Suzuki, T. Murase, Y. Yurikusa, M. Akatsu, Y. Enari, T. Hokuue, A. Tomita, N. Kishimoto, T. Ohshim… 展开作者
K. Inami, T. Mori, T. Matsumura, K. Kurimoto, S. Hasegawa, Y. Suzuki, T. Murase, Y. Yurikusa, M. Akatsu, Y. Enari, T. Hokuue, A. Tomita, N. Kishimoto, T. Ohshima, T. Ihara, H. Nishizawa
We have developed a 4-channel multi-anode MCP-PMT, SL10, which exhibits a performance of sigma_TTS ~ 30 ps for single photons with G ~ 10^6 and QE=20% under a magnetic field of B <= 1.5 T. The cross-talk among anodes has been extensively studied. We have taken two measures to suppress it: one is to configure the SL10 to an effectively independent 4 small pieces of MCP-PMT's by segmenting an electrode of the second MCP-layer; the other is to use a constant fractional discriminator. Remarkable improvement has been achieved.
The motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance. MCP-PMTs based on two different designs were tested.The magnetic field tolerance of MCP-PMT based on a design providing independently biased voltages showed a significant improvement (up to 0.7 T) compared to the one utilizing an internal resistor chain design (up to 0.1 T), indicating the importance of individually adjustable voltages. The effects of the ro…
In order to develop a long-lifetime MCP-PMT under high rates of circumstance, we investigated the degradation of the quantum efficiency (QE) of PMT's with a multialkali photocathode. We found that not only positive ions, but also neutral residual gases would damage the photocathode resulting in an enhancement of the work function; their countermeasures were established in newly manufactured square-shaped MCP-PMT's with 4 or 4x4 multi-anodes. The performances of the PMT's were measured: QE was stable up to an integrated amount of anode output charge of 2-3 C/cm^2, while keeping other basic perf…
This paper reports on the time resolution of two photodetectors operated as single photon counters at high rate: a Hamamatsu R13742-103-M64 "conventional" (based on metal dynodes) multi-anode photomultiplier tube (MaPMT) and a Hamamatsu R10754-07-M16 microchannel plate photomultiplier tube (MCP-PMT). The MCP-PMT shows a time resolution (transit time spread, or jitter) of ~70 ps FWHM (~30 ps RMS) at low photon rates, but saturates above ~100 kHz/mm^2. The MaPMT can handle photon counting rates up to the highest tested, 10 MHz/mm^2. Its time resolution is ~250 ps FWHM (~110 ps RMS) when only the…
We have measured and compared the characteristics of ALD-coated Planacon MCP-PMTs (XP85112/A1-Q-L) with their non-ALD counterparts (XP85012/A1-Q). While the later show excellent performance, the ALD-coated sensors have surprisingly low current saturation levels (~two orders of magnitude lower than expected) and extremely high gain recovery time (more than 7 orders of magnitude higher than expected). We suspect that these problems might be caused by the unexpected side-effects of the ALD process. To make a definite conclusion, more samples need to be tested, preferably from different production…
We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We als…
The linearity of charge response is an important feature of photomultiplier tubes (PMT) for physics measurements, especially the newly developed 20" MCP-PMT. In this paper, in addition to the traditional method of double light sources, we applied another relative method of 20" PMT to 3" PMT to measure the linearity of the 20" dynode and MCP PMTs in pulse mode with a waveform digitizer. The measurements show a good linear response of 20" PMTs to 1,000 photoelectrons (p.e.). The correlations of the amplitude, rise-time, fall-time, FWHM, baseline recovery, overshoot, and late-pulse to the output …
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection module for the positron emission tomography using the liquid detection media, the tri-methyl bismuth. In this study we use the commercial MCP-PMT Planacon from Photonis, with 32x32 anode structure. The PCB…
We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT XP85012. Amplified PMT signals are digitized by the SAMPIC module with high readout rate, up to $10^5$ events/s, and a negligible contribution to the time resolution, below 20 ps (FWHM). We developed a fast 2D scanning system to calibrate the PMT time response and studied in details the timing characteristics of the Planacon PMT. Using a radioactive $^{22}$N…
JUNO is a 20-kton liquid scintillator detector aiming to determine the neutrino mass ordering, precisely measure the oscillation parameters, detect the astrophysical neutrinos and search for exotic physics. It is designed to reach an energy resolution of 3% at 1 MeV with the highest ever PMT coverage, using two types of 20 inch phototubes: MCP-PMT from NNVT and dynode-PMT from Hamamatsu. In this article, the gain and charge response of the MCP and dynode PMTs are investigated with the study of JUNO Central Detector prototype. The linearity of the MCP-PMT charge output is measured too to check …
Aging experiments of a novel type of large area MCP-PMT made by JUNO collaboration were conducted.In these aging experiments, the multi-photoelectron spectrum and single photoelectron spectrum were measured daily,as well as the MCP resistance of the second PMT before and after the experiment. Two PMTs were aged successivelyfor cross check. The first PMT was aged for 52 days, while the other one was aged for 84 days. In order to study the mechanism of the aging process, the high voltage on the second PMT was increased to accelerate its aging process when the cumulative output of charge from its…
The high flux of charged particles interacting with the CMS Forward Hadron Calorimeter PMT windows introduced a significant background for the trigger and offline data analysis. During Long Shutdown 1, all of the original PMTs were replaced with multi-anode, thin window photomultiplier tubes. At the same time, the back-end electronic readout system was upgraded to μTCA readout. The experience with commissioning and calibration of the Forward Hadron Calorimeter is described as well as the μTCA system. The upgrade was successful and provided quality data for Run 2 data-analysis at 13 TeV.
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n=1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS pi2 beam line in November, 2002. To evaluate systematically the …
Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected; this is in contrast to conventional MCPs where about 50% of photoelectrons are lost at the MCP stage. The drawback of the Hi-CE MCPs is a small degradation of the transfer time spread (TTS). However for applications where no sub-ns time resolution is required the implementation of Hi-CE MCPs is extremely beneficial, as it improves the detection efficiency of th…
This report highlights two different types of cross-talk in the photodetectors of the miniTimeCube neutrino experiment. The miniTimeCube detector has 24 $8 \times 8$-anode Photonis MCP-PMTs Planacon XP85012, totalling 1536 individual pixels viewing the 2-liter cube of plastic scintillator.
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using a 20 kiloton underground liquid scintillator detector (CD). One of the keys is the energy resolution of the CD to reach <3% at 1 MeV, where totally 15,000 MCP-PMT will be used. The optimization of the 20-inch MCP-PMT is very important for better detection efficiency and stable performance. In this work, we will show the study to optimize the MCP-PMT working configuration for charge measurement. Particularly, the quality of PMT signal is another key for high-precision neutrino experim…
Large-Area Picosecond Photo-Detectors (LAPPDs) show great potential for expanding the performance envelope of Micro-Channel Plates (MCPs) to areas of up to 20 x 20 cm and larger. Such scaling introduces new challenges, including how to meet the electronics readout burden of ever larger area MCPs. One solution is to replace the traditional grid anode used for readout with a microwave stripline anode, thus allowing the channel count to scale with MCP width rather than area. However, stripline anodes introduce new issues not commonly dealt with in grid-anodes, especially as their length increases…
The Argonne micro-channel plate photomultiplier tube (MCP-PMT) is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein \mbox{6 $\times$ 6 cm$^2$} sized detectors are made at Argonne National Laboratory. Measurements of the properties of these detectors, including gain, time and spatial resolution, dark count rates, cross-talk and sensitivity to magnetic fields are reported. In addition, possible applications of these devices in future neutrino and collider physics experiments are discussed.
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial depe…
We have designed and tested a robust 20 $\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10nm-thick NiCr film deposited on a 96% pure Al$_2$O$_3$ 3mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put i…
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time resolutions of 30-50 psec for single photons. Incorporating a capacitively-coupled anode allows for the use of external pickup electrodes optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be implemented as a printed circuit card with a pattern chosen to match the specific application needs. The electrode elements are typically e…
The Jiangmen Underground Neutrino Observatory (JUNO) will install about 18,000 20-inch Photomultiplier Tubes (PMTs) in the center detector to achieve 3%/sqrt(E(MeV)) energy resolution. From the full detector Monte Carlo (MC) simulation, besides the liquid scitillator (LS) and Acrylic nodes, PMT glass has the largest contribution to the natural radioactive background. Various technologies have been developed in the Chinese industry to control the environment and to improve the production process. We have monitored the glass production for more than two months, and the radioactivity in glass was…
Development and characterization of hybrid MCP-PMT with embedded Timepix4 ASIC used as pixelated anode
INFN, Division of Ferrara(意大利国家核物理研究所费拉拉分部);Dept. of Physics and Earth Science, University of Ferrara(费拉拉大学地球科学与物理学系);EP Department, CERN(欧洲核子研究中心实验物理部)
A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77~cm long, 28~cm diameter, 40~kg cylindrical water mass instrumented with a combination of commercial $5.1\times5.1$~cm$^2$ micro-channel plate photo-multipliers (MCP-PMT) and $6.7\times6.7$~cm$^2$ mirrors. Five MCP-PMTs are installed in two columns along the OTPC cylinder in a small-angle stereo configuration. A mirror is mounted opposite eac…
A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast micro-channel plate PMTs (MCP-PMT), and readout by a dedicated FPGA (Field Programmable Gate Array) based front-end electronics. The full electronics chain consists of a programmable differential amplifier, a dual-threshold differential discriminator, and a timestamp Time-to-Digital convertor. By splitting a MCP-PMT output signal into two identical electronics ch…
Hamamatsu single anode R7761 and multi-anode R5900-00-M16 Photomultiplier Tubes have been characterized for use in a Secondary Emission (SE) Ionization Calorimetry study. SE Ionization Calorimetry is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The different operation modes used in these tests were developed by modifying the conventional PMT bias circuit. These modifications were simple changes to the arrangement of the voltage dividers of the baseboard circuits. The PMTs with modified bases, referred to as operating in SE mode, are used as a…
An event-counting thermal neutron imaging detector based on 3 mol % natGd2O3 doped micro channel plate (MCP) has been developed and tested. Thermal neutron imaging experiment was carried out with a low flux neutron beam. Detection efficiency of 33 % was achieved with only one doped MCP. The spatial resolution of 72 μm RMS is currently limited by the readout anode. A detector with larger area and improved readout method is now being developed.
Microchannel plates (MCP) are the basis for many spatially-resolved single-particle detectors such as ICCD or I-sCMOS cameras employing image intensifiers (II), MCPs with delay-line anodes for the detection of cold gas particles or Cherenkov radiation detectors. However, the spatial characterization provided by an MCP is severely limited by cross-talk between its microchannels, rendering MCP and II ill-suited for autocorrelation measurements. Here we present a cross-talk subtraction method experimentally exemplified for an I-sCMOS based measurement of pseudo-thermal light second-order intensit…
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position responses to high-energy $α$ particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it …
CMS-HF Calorimeters have been undergoing a major upgrade for the last couple of years to alleviate the problems encountered during Run I, especially in the PMT and the readout systems. In this poster, the problems caused by the old PMTs installed in the detectors and their solutions will be explained. Initially, regular PMTs with thicker windows, causing large Cherenkov radiation, were used. Instead of the light coming through the fibers from the detector, stray muons passing through the PMT itself produce Cherenkov radiation in the PMT window, resulting in erroneously large signals. Usually, …
Reliability assessment in concerned with the analysis of devices and systems whose individual components are prone to fail. This reliability analysis documents the process and results of reliability determination of the JEM-EUSO photomultiplier tube component using the methods 217 Plus. Quantum efficiency degradation and radiation hardness assurance. In conclussion, the levels of damage suffered by the PMTs which comprise the focal surface of JEM-EUSO Space Telescope, are acceptable. The results show as well the greatest contribution to the failure is due to radiation SET. The guaranteed perfo…
A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The syste…
Design and characterization of a photosensor system for the RELICS experiment
Westlake University(西湖大学);Westlake Institute for Advanced Study(西湖高等研究院);Tsinghua University(清华大学);Sun Yat-sen University(中山大学);The Chinese University of Hong Kong (Shenzhen)(香港中文大学(深圳));Beihang University(北京航空航天大学);University of Science and Technology of China(中国科学技术大学)