I present a novel algorithm for reconstructing the Wigner function from homodyne statistics. The proposed method, based on maximum-likelihood estimation, is capable of compensating for detection losses in a numerically stable way.
We show that data from homodyne-like detection based on photon-number-resolving (PNR) detectors may be effectively exploited to reconstruct quantum states of light using the tomographic reconstruction techniques originally developed for homodyne detection based on photodiodes. Our results open new perspectives to quantum state reconstruction, and pave the way to the use of PNR-based homodyne-like detectors in quantum information science.
An adaptive optimization technique to improve precision of quantum homodyne tomography is presented. The method is based on the existence of so-called null functions, which have zero average for arbitrary state of radiation. Addition of null functions to the tomographic kernels does not affect their mean values, but changes statistical errors, which can then be reduced by an optimization method that "adapts" kernels to homodyne data. Applications to tomography of the density matrix and other relevant field-observables are studied in detail.
An analysis of the homodyne tomography process that is often used to determine the Wigner functions of quantum optical states is performed to consider the effects of the spatiotemporal degrees of freedom. The homodyne tomography process removes those parts of the input state that are not associated with the mode of the local oscillator by tracing out those degrees of freedom. Using a functional approach to incorporate all the spatiotemporal degrees of freedom, we find that this reduction in the degrees of freedom introduces distortions in the observed Wigner function. The analysis also shows h…
We provide optimized recursion relations for homodyne tomography. We improve previous methods by mitigating the divergences intrinsic in the calculation of the pattern functions used previously, and detail how to implement the data analysis through Monte Carlo simulations. Our refinements are necessary for the reconstruction of excited quantum states which populate a high-dimensional subspace of the electromagnetic field Hilbert space. We also present a Julia package for the analysis and the reconstruction method.
The effect of the detector electronic noise in an optical homodyne tomography experiment is shown to be equivalent to an optical loss if the detector is calibrated by measuring the quadrature noise of the vacuum state. An explicit relation between the electronic noise level and the equivalent optical efficiency is obtained and confirmed in an experiment with a narrowband squeezed vacuum source operating at an atomic rubidium wavelength.
I propose an iterative expectation maximization algorithm for reconstructing a quantum optical ensemble from a set of balanced homodyne measurements performed on an optical state. The algorithm applies directly to the acquired data, bypassing the intermediate step of calculating marginal distributions. The advantages of the new method are made manifest by comparing it with the traditional inverse Radon transformation technique.
A single photon, delocalized over two optical modes, is characterized by means of quantum homodyne tomography. The reconstructed four-dimensional density matrix extends over the entire Hilbert space and thus reveals, for the first time, complete information about the dual-rail optical quantum bit as a state of the electromagnetic field. The experimental data violate the Bell inequality albeit with a loophole similar to the detection loophole in photon counting experiments.
We derive various sampling functions for multimode homodyne tomography with a single local oscillator. These functions allow us to sample multimode s-parametrized quasidistributions, density matrix elements in Fock basis, and s-ordered moments of arbitrary order directly from the measured quadrature statistics. The inevitable experimental losses can be compensated by proper modification of the sampling functions. Results of Monte Carlo simulations for squeezed three-mode state are reported and the feasibility of reconstruction of the three-mode Q-function and s-ordered moments from 10^7 sample…
In this paper, we study how a displacement of a quantum system appears under a change of relativistic reference frame. We introduce a generic method in which a displacement operator in one reference frame can be transformed into another reference frame. It is found that, when moving between non-inertial reference frames there can be distortions of phase information, modal structure and amplitude. We analyse how these effects affect traditional homodyne detection techniques. We then develop an in principle homodyne detection scheme which is robust to these effect, called the ideal homodyne dete…
We propose a general method for measuring an arbitrary observable of a multimode electromagnetic field using homodyne detection with a single local oscillator. In this method the local oscillator scans over all possible linear combinations of the modes. The case of two modes is analyzed in detail and the feasibility of the measurement is studied on the basis of Monte-Carlo simulations. We also provide an application of this method in tomographic testing of the GHZ state.
A self-homodyne detection scheme is proposed to perform two-mode tomography on a twin-beam state at the output of a nondegenerate optical parametric amplifier. This scheme has been devised to improve the matching between the local oscillator and the signal modes, which is the main limitation to the overall quantum efficiency in conventional homodyning. The feasibility of the measurement is analyzed on the basis of Monte-Carlo simulations, studying the effect of non-unit quantum efficiency on detection of the correlation and the total photon-number oscillations of the twin-beam state.
We present and demonstrate a method for optical homodyne tomography based on the inverse Radon transform. Different from the usual filtered back-projection algorithm, this method uses an appropriate polynomial series to expand the Wigner function and the marginal distribution and discretize Fourier space. We show that this technique solves most technical difficulties encountered with kernel deconvolution based methods and reconstructs overall better and smoother Wigner functions. We also give estimators of the reconstruction errors for both methods and show improvement in noise handling proper…
We present a continuous-variable experimental analysis of a two-photon Fock state of free-propagating light. This state is obtained from a pulsed non-degenerate parametric amplifier, which produces two intensity-correlated twin beams. Counting two photons in one beam projects the other beam in the desired two-photon Fock state, which is analyzed by using a pulsed homodyne detection. The Wigner function of the measured state is clearly negative. We developed a detailed analytic model which allows a fast and efficient analysis of the experimental results.
Continuous-variable (CV) photonic states are of increasing interest in quantum information science, bolstered by features such as deterministic resource state generation and error correction via bosonic codes. Data-efficient characterization methods will prove critical in the fine-tuning and maturation of such CV quantum technology. Although Bayesian inference offers appealing properties -- including uncertainty quantification and optimality in mean-squared error -- Bayesian methods have yet to be demonstrated for the tomography of arbitrary CV states. Here we introduce a complete Bayesian qua…
Optical homodyne tomography is discussed in the context of classical image processing. Analogies between these two fields are traced and used to formulate an iterative numerical algorithm for reconstructing the Wigner function from homodyne statistics.
We review experimental work on the measurement of the quantum state of optical fields, and the relevant theoretical background. The basic technique of optical homodyne tomography is described with particular attention paid to the role played by balanced homodyne detection in this process. We discuss some of the original single-mode squeezed-state measurements as well as recent developments including: other field states, multimode measurements, array detection, and other new homodyne schemes. We also discuss applications of state measurement techniques to an area of scientific and technological…
Pulsed homodyne quantum tomography usually requires a high detection efficiency limiting its applicability in quantum optics. Here, it is shown that the presence of low detection efficiency ($<50\%$) does not prevent the tomographic reconstruction of quantum states of light, specifically, of Gaussian type. This result is obtained by applying the so-called "minimax" adaptive reconstruction of the Wigner function to pulsed homodyne detection. In particular, we prove, by both numerical and real experiments, that an effective discrimination of different Gaussian quantum states can be achieved. Our…
This review covers latest developments in continuous-variable quantum-state tomography of optical fields and photons, placing a special accent on its practical aspects and applications in quantum information technology. Optical homodyne tomography is reviewed as a method of reconstructing the state of light in a given optical mode. A range of relevant practical topics are discussed, such as state-reconstruction algorithms (with emphasis on the maximum-likelihood technique), the technology of time-domain homodyne detection, mode matching issues, and engineering of complex quantum states of ligh…
We propose a procedure for tomographic characterization of continuous variable quantum operations which employs homodyne detection and single-mode squeezed probe states with a fixed degree of squeezing and anti-squeezing and a variable displacement and orientation of squeezing ellipse. Density matrix elements of a quantum process matrix in Fock basis can be estimated by averaging well behaved pattern functions over the homodyne data. We show that this approach can be straightforwardly extended to characterization of quantum measurement devices. The probe states can be mixed, which makes the pr…
Homodyne tomography provides a way for measuring generic field-operators. Here we analyze the determination of the most relevant quantities: intensity, field, amplitude and phase. We show that tomographic measurements are affected by additional noise in comparison with the direct detection of each observable by itself. The case of of coherent states has been analyzed in details and earlier estimations of tomographic precision are critically discussed.
We investigate the performance of a Kennedy receiver, which is known as a beneficial tool in optical coherent communications, to the quantum state discrimination of the two superpositions of vacuum and single photon states corresponding to the $\hatσ_x$ eigenstates in the single-rail encoding of photonic qubits. We experimentally characterize the Kennedy receiver in vacuum-single photon two-dimensional space using quantum detector tomography and evaluate the achievable discrimination error probability from the reconstructed measurement operators. We furthermore derive the minimum error rate ob…
Quantum state tomography aims to determine the quantum state of a system from measured data and is an essential tool for quantum information science. When dealing with continuous variable quantum states of light, tomography is often done by measuring the field amplitudes at different optical phases using homodyne detection. The quadrature-phase homodyne measurement outputs a continuous variable, so to reduce the computational cost of tomography, researchers often discretize the measurements. We show that this can be done without significantly degrading the fidelity between the estimated state …
We present a comprehensive theory and an easy to follow method for the design and construction of a wideband homodyne detector for time-domain quantum measurements. We show how one can evaluate the performance of a detector in a specific time-domain experiment based on electronic spectral characteristic of that detector. We then present and characterize a high-performance detector constructed using inexpensive, commercially available components such as low-noise high-speed operational amplifiers and high-bandwidth photodiodes. Our detector shows linear behavior up to a level of over 13 dB clea…
Russian Quantum Center(俄罗斯量子中心);Moscow Institute of Physics and Technology(莫斯科物理技术学院);University of Oxford(牛津大学)
Complete characterization of states and processes that occur within quantum devices is crucial for understanding and testing their potential to outperform classical technologies for communications and computing. However, solving this task with current state-of-the-art techniques becomes unwieldy for large and complex quantum systems. Here we realize and experimentally demonstrate a method for complete characterization of a quantum harmonic oscillator based on an artificial neural network known as the restricted Boltzmann machine. We apply the method to optical homodyne tomography and show it t…
Continuous variable quantum state tomography is one of the most powerful techniques to study the properties of light fields in quantum optics. However, the need for a fixed phase reference has so far prevented widespread usage in other fields such as semiconductor spectroscopy. Here, we introduce non-stationary quantum state tomography, which adapts the technique to the special requirements of ultrafast spectroscopy. In detail, we gain access to the amplitude and phase of light fields with a temporal resolution of about 100\,fs without the need for a fixed phase reference. Further, we show how…
In quantum optics, the quantum state of a light beam is represented through the Wigner function, a density on $\mathbb R^2$ which may take negative values but must respect intrinsic positivity constraints imposed by quantum physics. In the framework of noisy quantum homodyne tomography with efficiency parameter $1/2 < η\leq 1$, we study the theoretical performance of a kernel estimator of the Wigner function. We prove that it is minimax efficient, up to a logarithmic factor in the sample size, for the $\mathbb L_\infty$-risk over a class of infinitely differentiable. We compute also the lower …
The certificate of success for a number of important quantum information processing protocols, such as entanglement distillation, is based on the difference in the entanglement content of the quantum states before and after the protocol. In such cases, effective bounds need to be placed on the entanglement of non-local states consistent with statistics obtained from local measurements. In this work, we study numerically the ability of a novel type of homodyne detector which combines phase sensitivity and photon-number resolution to set accurate bounds on the entanglement content of two-mode qu…
We experimentally demonstrate that a non-classical state prepared in an atomic memory can be efficiently transferred to a single mode of free-propagating light. By retrieving on demand a single excitation from a cold atomic gas, we realize an efficient source of single photons prepared in a pure, fully controlled quantum state. We characterize this source using two detection methods, one based on photon-counting analysis, and the second using homodyne tomography to reconstruct the density matrix and Wigner function of the state. The latter technique allows us to completely determine the mode o…
We design and demonstrate on-chip homodyne detection operating in the quantum regime, i.e. able to detect genuine nonclassical features. Our setup exploits a glass-integrated homodyne analyzer (IHA) entirely fabricated by femtosecond laser micromachining. The IHA incorporates on the same chip a balanced waveguide beam splitter and a thermo-optic phase shifter, allowing us to record homodyne traces at different phases and to perform reliable quantum state tomography. In particular, we show that the IHA allows for the detection of nonclassical features of continuous-variable quantum states, such…
We describe a new scheme for the measurement of mean photon flux at an arbitrary optical sideband frequency using homodyne detection. Experimental implementation of the technique requires an AOM in addition to the homodyne detector, and does not require phase locking. The technique exhibits polarisation, frequency and spatial mode selectivity, as well as much improved speed, resolution and dynamic range when compared to linear photodetectors and avalanche photo diodes (APDs), with potential application to quantum state tomography and information encoding using an optical frequency basis. Exper…
We describe a novel tool for the quantum characterization of optical devices. The experimental setup involves a stable reference state that undergoes an unknown quantum transformation and is then revealed by balanced homodyne detection. Through tomographic analysis on the homodyne data we are able to characterize the signal and to estimate parameters of the interaction, such as the loss of an optical component, or the gain of an amplifier. We present experimental results for coherent signals, with application to the estimation of losses introduced by simple optical components, and show how the…
We reveal that quadrature squeezing can result in significantly better quantum-estimation performance with quantum heterodyne detection (of H. P. Yuen and J. H. Shapiro) as compared to quantum homodyne detection for Gaussian states, which touches an important aspect in the foundational understanding of these two schemes. Taking single-mode Gaussian states as examples, we show analytically that the competition between the errors incurred during tomogram processing in homodyne detection and the Arthurs-Kelly uncertainties arising from simultaneous incompatible quadrature measurements in heterody…
In quantum physics, all measured observables are subject to statistical uncertainties, which arise from the quantum nature as well as the experimental technique. We consider the statistical uncertainty of the so-called sampling method, in which one estimates the expectation value of a given observable by empirical means of suitable pattern functions. We show that if the observable can be written as a function of a single directly measurable operator, the variance of the estimate from the sampling method equals to the quantum mechanical one. In this sense, we say that the estimate is on the qua…
We construct a generalized Markov kernel which transforms the observable associated with the homodyne tomography into a covariant phase space observable with a regular kernel state. Illustrative examples are given in the cases of a 'Schrodinger cat' kernel state and the Cahill-Glauber s-parametrized distributions. Also we consider an example of a kernel state when the generalized Markov kernel cannot be constructed.
We propose a refined iterative likelihood-maximization algorithm for reconstructing a quantum state from a set of tomographic measurements. The algorithm is characterized by a very high convergence rate and features a simple adaptive procedure that ensures likelihood increase in every iteration and convergence to the maximum-likelihood state. We apply the algorithm to homodyne tomography of optical states and quantum tomography of entangled spin states of trapped ions and investigate its convergence properties.
The intimate connection between the Banach space wavelet reconstruction method on homogeneous spaces with both singular and nonsingular vacuum vectors, and some of well known quantum tomographies, such as: Moyal-representation for a spin, discrete phase space tomography, tomography of a free particle, Homodyne tomography, phase space tomography and SU(1,1) tomography is explained. Also both the atomic decomposition and banach frame nature of these quantum tomographic examples is explained in details. Finally the connection between the wavelet formalism on Banach space and Q-function is discuss…
A pulsed balanced homodyne detector has been developed for precise measurements of electric field quadratures of pulsed optical quantum states. A high level of common mode suppression (> 85 dB) and low electronic noise (730 electrons per pulse) provide a signal to noise ratio of 14 dB for the measurement of the quantum noise of individual pulses. Measurements at repetition rates up to 1 MHz are possible. As a test, quantum tomography of the coherent state is performed and the Wigner function and the density matrix are reconstructed with a 99.5% fidelity. The detection system can also be used f…
We present a method of generation of the Greenberger-Horne-Zeilinger state involving type II and type I parametric downconversion, and triggering photodetectors. The state generated by the proposed experimental set-up can be reconstructed through multi-mode quantum homodyne tomography. The feasibility of the measurement is studied on the basis of Monte-Carlo simulations.
We estimate the quantum state of a light beam from results of quantum homodyne measurements performed on identically prepared quantum systems. The state is represented through the Wigner function, a generalized probability density on $\mathbb{R}^2$ which may take negative values and must respect intrinsic positivity constraints imposed by quantum physics. The effect of the losses due to detection inefficiencies, which are always present in a real experiment, is the addition to the tomographic data of independent Gaussian noise. We construct a kernel estimator for the Wigner function, prove tha…
Quantum operations describe any state change allowed in quantum mechanics, including the evolution of an open system or the state change due to a measurement. In this letter we present a general method based on quantum tomography for measuring experimentally the matrix elements of an arbitrary quantum operation. As input the method needs only a single entangled state. The feasibility of the technique for the electromagnetic field is shown, and the experimental setup is illustrated based on homodyne tomography of a twin-beam.
We scrutinize the effects of non-ideal data acquisition on the homodyne tomograms of photon quantum states. The presence of a weight function, schematizing the effects of the finite thickness of the probing beam or equivalently noise, only affects the state reconstruction procedure by a normalization constant. The results are extended to a discrete mesh and show that quantum tomography is robust under incomplete and approximate knowledge of tomograms.
We present the full experimental reconstruction of Gaussian entangled states generated by a type--II optical parametric oscillator (OPO) below threshold. Our scheme provides the entire covariance matrix using a single homodyne detector and allows for the complete characterization of bipartite Gaussian states, including the evaluation of purity, entanglement and nonclassical photon correlations, without a priori assumptions on the state under investigation. Our results show that single homodyne schemes are convenient and robust setups for the full characterization of OPO signals and represent a…
We propose to measure the quantum state of a single mode of the radiation field in a cavity---the signal field---by coupling it via a quantum-non-demolition Hamiltonian to a meter field in a highly squeezed state. We show that quantum state tomography on the meter field using balanced homodyne detection provides full information about the signal state. We discuss the influence of measurement of the meter on the signal field.
We give a detailed account of an efficient search algorithm for the data pattern tomography proposed by J. Rehacek, D. Mogilevtsev, and Z. Hradil [Phys. Rev. Lett.~\textbf{105}, 010402 (2010)], where the quantum state of a system is reconstructed without a priori knowledge about the measuring setup. The method is especially suited for experiments involving complex detectors, which are difficult to calibrate and characterize. We illustrate the approach with the case study of the homodyne detection of a nonclassical photon state.
We propose to experimentally test the nonclassicality of quantum states through homodyne tomography. For single-mode states we check violations of inequalities involving the photon-number probability. For two-mode states we test the nonclassicality by reconstructing some suitable number-operator functions. The test can be performed with available quantum efficiency of homodyne detection, by measuring the pertaining quantities on the corresponding noisy states.
Quantum state tomography is both a crucial component in the field of quantum information and computation, and a formidable task that requires an incogitably large number of measurement configurations as the system dimension grows. We propose and experimentally carry out an intuitive adaptive compressive tomography scheme, inspired by the traditional compressed-sensing protocol in signal recovery, that tremendously reduces the number of configurations needed to uniquely reconstruct any given quantum state without any additional a priori assumption whatsoever (such as rank information, purity, e…
We present a new indirect method to measure the quantum state of a single mode of the electromagnetic field in a cavity. Our proposal combines the idea of (endoscopic) probing and that of tomography in the sense that the signal field is coupled via a quantum-non-demolition Hamiltonian to a meter field on which then quantum state tomography is performed using balanced homodyne detection. This technique provides full information about the signal state. We also discuss the influence of the measurement of the meter on the signal field.
Using a recent result of Albini et al. to represent quantum homodyne tomography in terms of a single observable (as a normalized positive operator measure) we construct a generalized Markov kernel which transforms (the measurement outcome statistics of) this observable into (the measurement outcome statistics of) a covariant phase space observable. We also consider the inverse question. Finally, we add some remarks on the quantum theoretical justification of the experimental implementations of these observables in terms of balanced homodyne and 8-port detection techniques, respectively.
We propose a strictly local quantum tomography protocol for a bipartite system. We show that the joint density matrix of an arbitrary two-mode Gaussian state, entangled or not, is obtained via local operations and classical communication only. In contrast to previous proposals, simultaneous homodyne measurements (HM) on both modes are replaced by local homodyne detections and a set of local projective measurements.
Precise reconstruction of unknown quantum states from measurement data, a process commonly called quantum state tomography, is a crucial component in the development of quantum information processing technologies. Many different tomography methods have been proposed over the years. Maximum likelihood estimation is a prominent example, being the most popular method for a long period of time. Recently, more advanced neural network methods have started to emerge. Here, we go back to basics and present a method for continuous variable state reconstruction that is both conceptually and practically …
Coherent-state quantum process tomography (csQPT) is a method of completely characterizing a quantum-optical "black box" by probing it with coherent states and performing homodyne measurements on the output [M. Lobino et al, Science 322, 563 (2008)]. We present a technique for csQPT that is fully based on statistical inference, specifically, quantum expectation-maximization. The method relies on the Jamiolkowski isomorphism and iteratively reconstructs the process tensor in the Fock basis directly from the experimental data. This approach permits incorporation of a priori constraints into the …