We have developed commercial prototypes of sealed gaseous detectors combined with CsI photocathodes and/or filled with photosensitive vapors. The rirst results of application of these devices for the detection of flames in daylight conditions and for the detection of scintillation lights from noble liquids will be presented. The main conclusion from our studies is that for some applications the sealed UV sensitive gaseous detectors have superior performance (higher practical quantum efficiency and better signal to noise ratio) than existing commercial UV sensitive detectors. Additionally, they are much cheaper.
There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrated, that both primary and secondary (due to the avalanche multiplication inside liquids) scintillation lights could be recorded by photosensitive gaseous detectors. The results of this work may allow one …
A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under high pressure of 2 atm mainly consist in selecting optimal voltages for ionization region and induction region. The dependence of the shape of Alpha particle spectra measured with relative gas gain on gas pressure (1.3 $\sim$ 2.0 atm) has been studied. The 8 groups of relative gas gain versus working voltage of THGEM expressed by weighting filed $E/P$ are no…
There are several proposals and projects today for building LXe Time Projection Chambers (TPCs) for dark matter search. An important element of these TPCs are the photomultipliers operating either inside LXe or in vapors above the liquid. We have recently demonstrated that photosensitive gaseous detectors (wire type and hole-type) can operate perfectly well until temperatures of LN2. In this paper results of systematic studies of operation of the photosensitive version of these detectors (combined with reflective or semi-transparent CsI photocathodes) in the temperature interval of 300-150 K a…
The GEM-based neutron detector has flourished in the past decade. However almost all the GEM-based neutron detectors work in the flow-gas mode, and the long-term performances of the detectors may be unstable due to the dynamic changes of atmospheric pressure and ambient temperature. In this paper, a sealed ceramic GEM-based neutron detector was developed at China Spallation Neutron Source (CSNS) and its sensitive area was 100 mm * 100 mm. The characterizations of the detector were presented and discussed, which included the plateau curve, the neutron beam profile, the neutron wavelength spectr…
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the electron multiplier and the gaseous-photomultiplier operation and characterization in a continuous mode. We present results on the properties of laboratory-produced K$_2$CsSb, Cs$_3$Sb and Na$_2$KSb photoca…
Advances in the technologies associated with position sensitive gaseous detectors especially featuring CsI as reflective photoconverters will be reviewed. These photodetectors represent the most effective solution for what concerns cost and performance in the case of large area Cherenkov imaging applications in relatively low rate (or low occupancy) high energy physics and astrophysics experiments. Moreover, they are the only choice when the Cherenkov detector is embedded in a magnetic field. Recently proposed single photon MPGDs (Micropattern Gaseous Detectors) will be also discussed in view …
Currently a revolution is happening in the development of gaseous detectors of photons and particles. Recently developed gaseous detectors with solid photocathodes are now replacing photosensitive wire chambers, which dominated for years in high energy and space flight experiments. We will review the main developments in this field as well as their applications in high-energy physics, medicine, industry and plasma diagnostics. New results on solid photocathodes coupled with gaseous micropattern/wire detectors will also be presented.
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in operation conditions adequate for TPCs and for gaseous photomultipliers. The concept was validated in a cascaded visible-sensitive gas avalanche photomultiplier operating at atmospheric pressure of Ar/CH_{4} (95/5) with a bi-alkali photocathode. While in previous works high gain, in excess of 10^{5}, was reached only in a pulse-gated cascaded-GEM gaseous photom…
Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design and optimization of such detectors are complex and time consuming tasks. Simulations, while being a powerful tool, strongly depend on the light transport models and demand accurate knowledge of many parameters, which are often not available. Here we describe an alternative approach based on the experimental evaluation of a detector using an isotropic point-l…
A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors have several important advantages over other conventional micropattern detectors and are unique for applications like the readout detectors for dual phase noble liquid TPCs and RICHs.
We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.
NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived …
Migdal effect is attracting interests because of the potential to enhance the sensitivities of direct dark matter searches to the low mass region. In spite of its great importance, the Migdal effect has not been experimentally observed yet. A realistic experimental approach towards the first observation of the Migdal effect in the neutron scattering was studied with Monte Carlo simulations. In this study, potential background rate was studied together with the event rate of the Migdal effect by a neutron source. It was found that a table-top sized $\sim (30\rm cm )^3$ position-sensitive gaseou…
There are several applications which require high position resolution UV imaging. For these applications we have developed and successfully tested a new version of a 2D UV single photon imaging detector based on a microgap RPC. The main features of such a detectors is the high position resolution - 30 micron in digital form and the high quantum efficiency (1-8% in the spectral interval of 220-140 nm). Additionally, they are spark- protected and can operate without any feedback problems at high gains, close to a streamer mode. In attempts to extend the sensitivity of RPCs to longer wavelengths …
We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace UVsensitive wire chambers for single-photon recording in Cherenkov and other detectors. Other hole-multipliers with patterned electrodes (Micro-Hole and Strip Plates) and improved ion-blocking properties are discussed; these permit reducing considerably photon- and ion-induced secondary effects. Photon detectors with other electron-multiplier techniques are bri…
In this paper we present a prototype of a Strip Resistive Thick GEM photosensitive gaseous detector filled with Ne and ethylferrocene vapours at a total pressure of 1 atm for an early forest fire detection system. Tests show that it is one hundred times more sensitive than the best commercial ultraviolet flame detectors and therefore, it is able to reliably detect a flame of 1.5x1.5x1.5 m3 at a distance of about 1km. An additional and unique feature of this detector is its imaging capability, which in combination with other techniques, may significantly reduce false fire alarms when operating …
We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary plates operating in a mode when the main amplification occurs between plates or between the capillary plate and the readout plate (parallel plate amplification mode). Results of these studies demonstrated that in the parallel-plate amplification mode one can reach both high gains (>100000) and good position resolutions (~100 micro meter) even with a single step arrangement. It offers a compact amplification structur…
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of extern…
NEWAGE(NEw generation WIMP search with an Advanced Gaseous tracking device Experiment) project is a direction-sensitive dark matter search experiment with a gaseous micro time-projection-chamber(micro-TPC). We report on the performance of the micro-TPC with a detection volume of 23x28x30 cm3 operated with a carbon-tetra uoride (CF4) of 0.2 bar.
NEWAGE is a direction-sensitive dark-matter-search experiment that uses a micro-patterned gaseous detector, or μ-PIC, as the readout. The main background sources are α-rays from radioactive contaminants in the μ-PIC. We have therefore developed a low-alpha-emitting μ-PICs and measured its performances. We measured the surface α-ray emission rate of the μ-PIC in the Kamioka mine using a surface α-ray counter based on a micro TPC.
Associated Particle Imaging (API) is a nuclear technique that allows for the nondestructive determination of 3D isotopic distributions. The technique is based on the detection of the alpha particles associated with the neutron emitted in the deuterium-tritium (DT) fusion reaction, which provides information regarding the direction and time of the emitted 14 MeV neutron. Inelastic neutron scattering leads to characteristic gamma-ray emission from certain isotopes, for example C-12, that can be correlated with the neutron interaction location. An API system consisting of a sealed-type neutron ge…
In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting the strips, we are able to reconstruct the radiation interaction points by resistive charge division. The detector achieved gains above $10^4$, energy resolution of 15.28% (FWHM) for 5.9keV X-rays, and position resolution of 1.2mm, while operating in Ar/CO$_2$(90/10) at atmospheric pressure.
Earlier we have developed and successfully tested a RICH detector prototype consisting in a CsI coated triple GEM operated in gas flushed mode In the given work, a modified version of this detector for a completely different application - fire safety- is presented. The detector operates in sealed mode and is combined with an optical system and a narrow band filter As a photosensitive element, a CsI photocathode coated with a thin layer of ethylferrocene was used. This detector is almost 1000 times more sensitive than the best commercial flame sensor; it has 100 times better time resolution and…
This article presents a detector system consisting of three components, a CMOS imaging array, a gaseous-detector structure with a Micromegas layout and a UV-photon sensitive CsI reflective photocathode. All three elements have been monolithically integrated using simple post-processing steps. The Micromegas structure and the CMOS imaging chip are not impacted by the CsI deposition. The detector operated reliably in He/isobutane mixtures and attained charge gains with single photons up to a level of 6 \cdot 10^4. The Timepix CMOS array permitted high resolution imaging of single UV-photons. The…
Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α…
The RD51 Collaboration, in charge of the development and dissemination of MicroPattern Gaseous Detectors (MPGD) since 2008, proposes to extend its activity, after 2018, for a further five-year term. Since the RD51 initial years, the community of MPGD developers and users has grown considerably. It is reflected by the many MPGD-based applications in high energy and nuclear physics experiments as well as in other basic and applied-research fields. They rely on the parallel progress of detector concepts and associated technologies. The cultural, infrastructure and networking support offered by RD…
A method is proposed to dump the spurious signals induced by fluorescence of the electrodes in gaseous detectors under strong X-Ray irradiation, introducing a special fluorescence suppressor electrode between the sensitive and the amplifying parts of the detector.
Simulation of the CYGNO Gaseous TPC Optical Readout
University of Coimbra(科英布拉大学);Gran Sasso Science Institute(格兰萨索科学研究所);Laboratori Nazionali del Gran Sasso(格兰萨索国家实验室);Laboratori Nazionali di Frascati(弗拉斯卡蒂国家实验室);University of Sheffield(谢菲尔德大学)
We are developing imaging and photon counting UV-MCP detectors, which are sensitive in the wavelength range from far ultraviolet to near ultraviolet. A good quantum efficiency, solar blindness and high spatial resolution is the aim of our development. The sealed detector has a Cs-activated photoactive layer of GaN (or similarly advanced photocathode), which is operated in semitransparent mode on (001)-MgF 2 . The detector comprises a stack of two long-life MCPs and a coplanar cross strip anode with advanced readout electronics. The main challenge is the flawless growth of the GaN photocathode …
Spectroscopic study of argon electroluminescence light with a wavelength-sensitive particle detector
Department of Physics, University of California, Davis(加州大学戴维斯分校物理系);CIEMAT, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas(能源、环境和技术研究研究中心)
The CYGNO experiment: a gaseous TPC with optical readout for rare events searches
University of Coimbra(科英布拉大学);Gran Sasso Science Institute(格兰萨索科学研究所);Laboratori Nazionali del Gran Sasso(格兰萨索国家实验室);Laboratori Nazionali di Frascati(弗拉斯卡蒂国家实验室);University of Sheffield(谢菲尔德大学)
Muon Tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons in matter is a promising technique for detecting heavily shielded high-Z radioactive materials (U, Pu) in cargo or vehicles. The technique uses the deflection of cosmic ray muons in matter to perform tomographic imaging of high-Z material inside a probed volume. A Muon Tomography Station (MTS) requires position-sensitive detectors with high spatial resolution for optimal tracking of incoming and outgoing cosmic ray muons. Micro Pattern Gaseous Detector (MPGD) technologies such as Gas Electron Multip…
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to thermal neutrons of a single-gap $^{10}B$-RPC is only about 6%. Aiming to overcome this limitation, we introduce a multi-layer $^{10}B$-RPCs detector with a stack of ten double-gap hybrid RPCs. A descr…
Plastic gas pipes are widely used in experimental setups for gaseous detectors, due to their flexibility and easiness of use. This report describes the characterization studies realized on the use of plastic gas pipes, particularly in relation to the accumulation of impurities in gas systems that they may cause. A laboratory setup has been implemented to evaluate the possible effects caused by plastic pipes, in terms of their specific impact on O2 and H2O accumulation and the consequences on detectors performance. As Single Wire Proportional Chambers are very sensitive to the presence of pollu…
Nowadays RPCs are in a booming phase: they are successfully used in many experiments, including LHC; there are ambitious plans to use them in several upgrade detectors and in some new experiments as well as in various applications. The aim of this paper is to highlight the main challenges which the RPC community may face in the next few years and which were addressed in talks presented at this conference. Examples could be: new and difficult requirements from experiments (and their upgrades) and applications, optimization and improvements of the existing traditional detector designs, improveme…
The performance of a novel tracking detector developed for the focal plane of the NSCL/FRIB S800 magnetic spectrometer is presented. The detector comprises a large-area drift chamber equipped with a hybrid Micro-Pattern Gaseous Detector (MPGD)-based readout. The latter consists of a position-sensitive Micromegas detector preceded by a two-layer M-THGEM multiplier as a pre-amplification stage. The signals from the Micromegas readout are processed by a data acquisition system based on the General Electronics for TPC (GET). The drift chamber has an effective area of around 60x30 cm^2, which match…