Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to thermal neutrons of a single-gap $^{10}B$-RPC is only about 6%. Aiming to overcome this limitation, we introduce a multi-layer $^{10}B$-RPCs detector with a stack of ten double-gap hybrid RPCs. A description of the detector design and the results of its characterization performed at the TREFF neutron beamline at the FRM II neutron facility are presented. The results demonstrate that the detection efficiency exceeds 60% for neutrons with a wavelength of 4.7 Å and the spatial resolution (FWHM) is about 0.25 mm and 0.35 mm in the X and Y direction, respectively.
A Monte Carlo simulation-based optimization of a multilayer 10B-RPC thermal neutron detector is performed targeting an increase in the counting rate capability while maintaining high (>50%) detection efficiency for thermal neutrons. The converter layer thicknesses of individual RPCs are optimized for several configurations of a detector containing a stack of 10 double gap RPCs. The results suggest that it is possible to reach a counting rate which is by a factor of eight higher in comparison to the rate of a detector with only one double-gap RPC. The effect of neutron scattering inside the det…
A novel concept for position-sensitive thermal neutron detectors based on thin-gap Resistive Plate Chambers (RPC) lined with a neutron converter layer is presented and its feasibility is discussed. Several detector architectures implementing a stack of RPCs in multilayer and inclined geometries are introduced. The results of a Monte Carlo simulation study are presented demonstrating the effect of the main detector design parameters on the expected detection efficiency and spatial resolution.
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined with a 2 $μ$m thick $^{10}B{_4}C$ neutron converter layer enriched in $^{10}B$ and a float glass anode. A detection efficiency of ${\approx}$ 6.2 ${\%}$ was measured for the neutron beam ($λ$ =2.5 $Å$) at normal incidence. A spatial resolution better than 0.5 mm FWHM was demonstrated.
We propose an alternative approach for the detection of fast neutrons in the energy range from 10-4 to 5 MeV based on 10B-RPCs (hybrid double-gap Resistive Plate Chambers with 10B4C neutron converters) surrounded by a polyethylene moderator. The detection efficiency as a function of the neutron energy is obtained in Monte Carlo simulations performed with the Geant4 toolkit for several detector configurations. The thickness of the neutron converter is optimized for the maximum efficiency. The results show that for this type of detector it is possible to obtain an average detection efficiency la…
We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements were performed at the V17 monochromatic neutron beamline (3.35 Ȧ) at the Helmholtz-Zentrum Berlin. For the $^{10}$B-RPCs with 0.28 mm thick float glass a maximum counting rate density of about $8\times 10^{3}$ $Hz/cm^{2}$ was obtained. In the case of low resistivity glass and ceramic, the counting rate density did not deviate from linear dependence on the n…
Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a statistical approach. Using experimental data, we compare the performance of this method with that of the centroid reconstruction. Both methods result in a similar image linearity/uniformity and spatial resolution. However, the statistical method allows to improve the image quality at the detector periphery, offers more flexible event filtering and allows to dev…
We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform over a large ultra-cold neutron velocity range. The designed titanium-boron-nickel multilayer film was deposited on silicon using a microwave plasma-assisted co-sputtering method (first, for test purpose, on silicon wafers, then directly on the surface of a CCD sensor). The obtained sensor was then tested using both cold and ultra-cold neutrons.
Gamma Neutron Radioactive Source Identification in Water Cherenkov Detectors
Departamento de Física de Neutrones, Centro Atómico Bariloche(中子物理系,巴拉德奥切原子能中心);Instituto Balseiro, CNEA-UNCuyo(巴尔塞罗研究所,CNEA-门多萨国立大学);Escuela de Física, Universidad Industrial de Santander(桑坦德工业大学生物物理学院);Departamento de Ciencias Básicas, Universidad Autónoma de Bucaramanga(巴兰基亚自治大学基础科学系);Fractalis Adventures & piensas.xyz(Fractalis探险与piensas.xyz);Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET)(国家科学研究委员会)
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and delayed neutron from IBD will provide the signature of $\barν_e$ event in ISMRAN. The number of segments with energy deposit ($\mathrm{N_{bars}}$) and sum total of these deposited energies are used as…