Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α$ $μ$-PIC" is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.
NEWAGE is a direction-sensitive dark-matter-search experiment that uses a micro-patterned gaseous detector, or μ-PIC, as the readout. The main background sources are α-rays from radioactive contaminants in the μ-PIC. We have therefore developed a low-alpha-emitting μ-PICs and measured its performances. We measured the surface α-ray emission rate of the μ-PIC in the Kamioka mine using a surface α-ray counter based on a micro TPC.
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
CERN(欧洲核子研究组织);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Stony Brook University(石溪大学);NCSR Demokritos(德谟克利特国家科学研究中心);Laboratório de Instrumentação e Física Experimental de Partículas (LIP)(粒子物理与实验仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰斐逊国家加速器装置);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);University of Bonn(波恩大学);CEA-Saclay(法国原子能和替代能源委员会萨克雷中心);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁杰尔·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
Caribou is a flexible open-source DAQ system developed and used within several collaborative frameworks (CERN EP R&D, RD50, AIDAinnova) for laboratory and high-rate beam tests and easy integration of new silicon-pixel detector prototypes. It uses common hardware, firmware and software components that are shared across different projects, thereby reducing the development effort and cost for such readout systems significantly. This contribution introduces the FASTPIX, APTS and DPTS detectors recently integrated in Caribou and their requirements in terms of waveform sampling and timing of digital…
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at the CERN SPS H4 secondary line. This work will present the main results of this prototype and the performance of the different detector configurations tested in 2016-18 beam campaigns: readouts (bulk…
The India based Neutrino Observatory (INO) is a mega science project of India, which is going to use near about 30, 000 Resistive Plate Chambers (RPC) as active detector elements for the study of atmospheric neutrino oscillations. Each RPC detector will consist of two orthogonally placed readout strips panel for picking the signals generated in the gas chamber. The area of RPC detector in INO-ICAL (Iron Calorimeter) experiment will be 2m x 2m, therefore the dimension of readout strips panel will also be of 2m x 2m. To get undistorted signals pass through the readout strips panel to frontend el…
Single photon avalanche diode (SPAD) arrays have proven themselves as serious candidates for time of flight positron emission tomography (PET). Discrete readout schemes mitigate the low-noise requirements of analog schemes and offer very fine control over threshold levels and timing pickup strategies. A high optical fill factor is paramount to timing performance in such detectors, and consequently space is limited for closely integrated electronics. Nonetheless, a production, daily used PET scanner must minimize bandwidth usage, data volume, data analysis time and power consumption and therefo…
The Micro Pixel Chamber (mu-PIC) using resistive electrodes has been developed and tested. The surface cathodes are made from resistive material, by which the electrical field is reduced when large current is flowed. Two-dimensional readouts are achieved by anodes and pickup electrodes, on which signals are induced. High gas gain (> 60000) was measured using 55Fe (5.9 keV) source, and very intensive spark reduction was attained under fast neutron. The spark rate of resistive mu-PIC was only 10^-4 times less than that of conventional mu-PIC at the gain of 10^4. With these developments, a new MP…
Differentiable Full Detector Simulation of a Projective Dual-Readout Crystal Electromagnetic Calorimeter with Longitudinal Segmentation and Precision Timing
In this paper we discuss a general approach to use SiPMs in different electrical configurations in combination with numerous scintillator materials for applications in nuclear instrumentation, such as calorimetry and timing. The "hybrid" configuration used in the PANDA detector was found to show the fastest timing properties with several hundred pico second response by combining the advantages of a large active area while avoiding high operation voltages and dark noise. A "parallel" configuration shows the largest light collection efficiency and is therefore suitable for energy measurements. S…
The next generation of Far-infrared and X-ray space observatories will require detector arrays with thousands of transition edge sensor (TES) pixel. It is extremely important to have a tool that is able to characterize all the pixels and that can give a clear picture of the performance of the devices. In particular, we refer to those aspects that can affect the global energy resolution of the array: logarithmic resistance sensitivity with respect to temperature and current ($α$ and $β$ parameters, respectively), uniformity of the TESs and the correct understanding of the detector thermal model…
Low frequency high precision laser interferometry is subject to excess laser-frequency-noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This approach is crucial to achieve picometer level sensitivities in the 0.1 mHz to 1 Hz regime, where laser frequency noise is usually high and couples into the measurement phase via arm-length mismatches in the interferometers. Here we describe the results achieved by frequency stabilising an external cavity diode laser to a quasi-monolithic unequal arm-length Mach-Zehnder interferom…
The Time-Of-Propagation detector is a Cherenkov particle identification detector based on quartz radiator bars for the Belle II experiment at the SuperKEKB electron-positron collider. The purpose of the detector is to identify the type of charged hadrons produced in electron-positron collisions, and requires a single photon timing resolution below 100 picoseconds. A novel front-end electronic system was designed, built, and integrated to acquire data from the 8192 microchannel plate photomultiplier tube channels in the detector. Waveform sampling of these analog signals is done by switched-cap…
We present the design and the test results of a dual-channel Vertical-Cavity Surface-Emitting Laser (VCSEL) driver ASIC LOCld65 for detector front-end readout. LOCld65 is designed in a commercial 65-nm CMOS technology with a power supply of 1.2 V. LOCld65 contains two separate channels with the same structure and the two channels share an I2C slave. Each channel consists of an input amplifier, four stages of limiting amplifiers (LAs), a high-current output driver, and a bias-current generator. In order to extend the bandwidth, the input amplifier uses an inductive peaking technique and the LAs…
We report on the design and sensitivity of a new torsion pendulum for measuring the performance of ultra-precise inertial sensors and for the development of associated technologies for space-based gravitational wave observatories and geodesy missions. The apparatus comprises a 1 m-long, 50 um-diameter, tungsten fiber that supports an inertial member inside a vacuum system. The inertial member is an aluminum crossbar with four hollow cubic test masses at each end. This structure converts the rotation of the torsion pendulum into translation of the test masses. Two test masses are enclosed in ca…
The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this is accomplished by using 3000 monolithic scintillator bars of 270$\times$5$\times$5 cm$^3$ size made of a fast plastic. Each bar is read out on the two long ends, and the needed time resolution of $σ_t$ $<$ 150 ps is reached with fast timing photomultipliers. In the present work, it is investigated whether silicon photomultiplier (SiPM) photosensors can be …
A discovery of a permanent electric dipole moment (EDM) of the neutron would provide one of the most important low energy tests of the discrete symmetries beyond the Standard Model of particle physics. A new search of neutron EDM, to be conducted at the spallation neutron source (SNS) at ORNL, is designed to improve the present experimental limit of ~10^-26 e-cm by two orders of magnitude. The experiment is based on the magnetic-resonance technique in which polarized neutrons precess at the Larmor frequency when placed in a static magnetic field; a non-zero EDM would be evident as a difference…
A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants for future rare-event-search experiments as well as other scientific fields. The design features and assembly techniques described here are motivated by the position and energy resolution required to reconstruct alpha and beta tracks while efficiently rejecting backgrounds. Results from a test setup using an $^{55}$Fe x-ray source indicate excellent operatio…
The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its final configuration, NeuLAND will consist of 3000 2.7 m $\times$ 5 cm $\times$ 5 cm big plastic scintillator bars that are read out on each end by fast timing photomultipliers. Here, data from a comprehensive study of an alternative light readout scheme using silicon photomultipliers (SiPM) are reported. For this purpose, a NeuLAND bar was instrumented on each …
The ARGO-YBJ experiment has been in stable data taking from November 2007 till February 2013 at the YangBaJing Cosmic Ray Observatory (4300 m a.s.l.). The detector consists of a single layer of Resistive Plate Chambers (RPCs) ( about 6700 m^2}) operated in streamer mode. The signal pick-up is obtained by means of strips facing one side of the gas volume. The digital readout of the signals, while allows a high space-time resolution in the shower front reconstruction, limits the measurable energy to a few hundred TeV. In order to fully investigate the 1-10 PeV region, an analog readout has been …
The solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm$^2$ at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small telescopic…
Studies of micro time projection chambers using negative ion gas (NI$μ$TPC) are conducted especially for direction-sensitive dark matter searches. A NI$μ$TPC enables to measure the absolute position in the drift direction for self-triggering TPCs. This study provides a development of a NI$μ$TPC using a micro pixel chamber ($μ$-PIC) with dedicated readout electronics, and an evaluation of the capability of three-dimensional absolute position reconstruction of nuclear recoil using a neutron source. The absolute track position was reconstructed throughout the drift volume with an efficiency of 70…
The QCD axion is one of the most compelling candidates to explain the dark matter abundance of the universe. With its extremely small mass ($\ll 1\,\mathrm{eV}/c^2$), axion dark matter interacts as a classical field rather than a particle. Its coupling to photons leads to a modification of Maxwell's equations that can be measured with extremely sensitive readout circuits. DMRadio-m$^3$ is a next-generation search for axion dark matter below $1\,μ$eV using a $>4$ T static magnetic field, a coaxial inductive pickup, a tunable LC resonator, and a DC-SQUID readout. It is designed to search for QCD…