M. Ambrosio, R. Brugnera, S. Dusini, B. Dulach, C. Fanin, G. Felici, F. Dal Corso, A. Garfagnini, F. Grianti, C. Gustavino, P. Monacelli, A. Paoloni, L. Stanco,… 展开作者
M. Ambrosio, R. Brugnera, S. Dusini, B. Dulach, C. Fanin, G. Felici, F. Dal Corso, A. Garfagnini, F. Grianti, C. Gustavino, P. Monacelli, A. Paoloni, L. Stanco, M. Spinetti, F. Terranova, L. Votano
备注:
6 pages, 10 figures, presented at the 2003 IEEE-NSS conference, Portland, OR, USA, October 20-24, 2003
The OPERA neutrino oscillation experiment foresees the construction of two magnetized iron spectrometers located after the lead-nuclear emulsion targets. The magnet is made up of two vertical walls of rectangular cross section connected by return yokes. The particle trajectories are measured by high precision drift tubes located before and after the arms of the magnet. Moreover, the magnet steel is instrumented with Resistive Plate Chambers that ease pattern recognition and allow a calorimetric measurement of the hadronic showers. In this paper we review the construction of the spectrometers. In particular, we describe the results obtained from the magnet and RPC prototypes and the installation of the final apparatus at the Gran Sasso laboratories. We discuss the mechanical and magnetic properties of the steel and the techniques employed to calibrate the field in the bulk of the magnet. Moreover, results of the tests and issues concerning the mass production of the Resistive Plate Chambers are reported. Finally, the expected physics performance of the detector is described; estimates rely on numerical simulations and the outcome of the tests described above.
To determine the magnetic field distribution in the KATRIN main-spectrometer with magnetic field sensors that are placed outside the main-spectrometer vessel one can utilize the absence of magnetic rotation in main-spectrometer volume. There a scalar magnetic potential V(~x) can be defined that fulfills the Laplace equation. Large numbers of magnetic field values on an outer surface of the main-spectrometer can be sampled by moving and fixed magnetic field sensors. These surface samples are used as boundary values in the relaxation of the Laplace equation for V(~x) and the magnetic field compo…
We report an analysis of electron-optical properties of a toroidal magnetic sector spectrometer and examine parameters for its implementation in a relativistic heavy-ion storage ring like HESR. For studies of free-free pair production in heavy-ion atom collisions this spectrometer exhibits very high efficiencies for coincident $e^+e^-$ pair spectroscopy over a wide range of momenta of emitted lepton pairs. The high coincidence efficiency of the spectrometer is the key for stringent tests of theoretical predictions for the coincident positron- and electron- emission characteristics and for the …
A method for circular e$^-$/e$^+$ accelerator beam energy measurement is proposed. Coordinate of an electron (or a positron) in a focusing magnetic spectrometer built in a circular accelerator depends on its energy, two spectrometer parameters, and the circulating beam energy. The spectrometer parameters can be defined using minimum electron energies from Compton backscattering with two laser wavelengths, and an additional photon coordinate detector. The photon detector is calibrated at once at well-known beam energy. The VEPP-4M collider has appropriate equipment for the method implementation…
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the electron neutrino mass with an unprecedented sensitivity of 0.2 eV/c2, using b decay electrons from tritium decay. For the control of magnetic field in the main spectrometer area of the KATRIN experiment a mobile magnetic sensor unit is constructed and tested at the KATRIN main spectrometer site. The unit moves on inner rails of the support structures of the low field shaping coils which are arranged along the the main spectrometer. The unit propagates on a caterpillar drive and contains an electro motor, battery pack, boar…
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the absolute neutrino mass scale with an unprecedented sensitivity of 0.2 eV/c2 (90% C.L.), using beta decay electrons from tritium decay. The kinetic energy of the decay electrons is measured using an electrostatic integrating main spectrometer (MS) with magnetic adiabatic collimation and requires a certain magnetic field profile. For the control of the magnetic field in the MS area two networks of mobile magnetic field sensor units are developed and commissioned. The radial system is operated close to the outer surface of the…
We present the development and performance of an optically detected magnetic resonance (ODMR) spectrometer. The spectrometer represents advances over similar instruments in three areas: i) the exciting light is a tunable laser source which covers much of the visible light range, ii) the optical signal is analyzed with a spectrograph, iii) the emitted light is detected in the near-infrared domain. The need to perform ODMR experiments on single-walled carbon nanotubes motivated the present development and we demonstrate the utility of the spectrometer on this material. The performance of the spe…
A new data acquisition system for the high resolution magnetic spectrometer Lintott at the superconducting Darmstadt electron linear accelerator S-DALINAC was developed. It allows inclusive and coincidence electron scattering experiments with event rates up to 10 kHz.
We report an analysis of electron-optical properties of a toroidal magnetic sector spectrometer and examine parameters for its implementation in a relativistic heavy-ion storage ring like HESR at the future FAIR facility. For studies of free-free pair production in heavy-ion atom collisions, this spectrometer exhibits very high efficiencies for coincident $e^+e^-$ pair spectroscopy over a wide range of momenta of emitted lepton pairs. The high coincidence efficiency of the spectrometer is the key for stringent tests of theoretical predictions for the phase space correlation of lepton vector mo…
We present a finite element calculation of the magnetic field (MagNet software) taken with the newly proposed PASTIS Coil, which uses a wide-angle banana shaped 3He Neuton Spin Filter cell (NSF) to cover a large range of scattering angle. The goal of this insert is to enable XYZ polarization analysis to be installed on the future thermal time-of flight spectrometer TOPAS.
The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic $Q$-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the forefront of using advanced neutron focusing optics such as elliptic guides, which enable the investigation of small samples under extreme conditions. Another advantage of MIRA is the modular assembly allowing for instrumental adaption to the needs of the experiment within a few hours. The development of new methods such as the spin-echo technique MIEZE is a…
We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency photomultiplier tube, is considered as the high-resolution and highly stable TOF detector. By means of Monte Carlo simulations it is demonstrated that the magnetic spectrometers at the MAMI electron-…
Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2T. In order not to disturb other experiments in the vicinity of aSPECT, we had to develop a magnetic field return yoke for the magnet system. While the return yoke must reduce the stray magnetic field, the internal magnetic field and i…
Physics cases of increasing interest in the recent years, such as the study of double charge exchange reactions for neutrino physics, require the study of very suppressed reaction channels in medium-heavy ion induced nuclear reactions. The main experimental challenges are the possibility to identify and detect the medium-heavy quasi-projectiles and the capability to measure very low cross-sections (few nb) with high sensitivity at very forward angles, including zero degree. The experimental techniques adopted in the setup of the MAGNEX magnetic spectrometer to face these issues are described i…
Knowledge of the precise rigidity dependence of the carbon flux is important in understanding the origin, acceleration and propagation of cosmic rays. The current status of the measurement of the carbon flux in cosmic rays with rigidity from 1.9 GV to 2.6 TV, based on 8.3 million events collected by the Alpha Magnetic Spectrometer during the first 5 years of operation, is presented.
A precision measurement by AMS of the antiproton-to-proton flux ratio in primary cosmic rays in the absolute rigidity range from 1 to 450 GV is presented based on $3.49\times10^5$ antiproton events and $2.42\times10^9$ proton events. Above $\sim60$ GV the antiproton to proton flux ratio is consistent with being rigidity independent. A decreasing behaviour is expected for this ratio considering the traditional models for the secondary antiproton flux.
The OLYMPUS experiment used a 0.3 T toroidal magnetic spectrometer to measure the momenta of outgoing charged particles. In order to accurately determine particle trajectories, knowledge of the magnetic field was needed throughout the spectrometer volume. For that purpose, the magnetic field was measured at over 36,000 positions using a three-dimensional Hall probe actuated by a system of translation tables. We used these field data to fit a numerical magnetic field model, which could be employed to calculate the magnetic field at any point in the spectrometer volume. Calculations with this mo…
A high power pulsed laser system has been installed on the high magnetic field muon spectrometer (HiFi) at the ISIS pulsed neutron and muon source, situated at the STFC Rutherford Appleton Laboratory in the UK. The upgrade enables one to perform light-pump muon-probe experiments under a high magnetic field, which opens new applications of muon spin spectroscopy. In this report we give an overview of the principle of the HiFi Laser system, and describe the newly developed techniques and devices that enable precisely controlled photoexcitation of samples in the muon instrument. A demonstration e…
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $σ/E \sim 6%/\sqrt E $, and pion/electron ($π/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exce…
We propose a new type of momentum spectrometer, which uses the RxB drift effect to disperse the charged particles in a uniformly curved magnetic field. This kind of RxB spectrometer is designed for the momentum analyses of the decay electrons and protons in the PERC (Proton and Electron Radiation Channel) beam station, which provides a strong magnetic field to guide the charged particles in the instrument. Instead of eliminating the guiding field, the RxB spectrometer evolves the field gradually to the analysing field, and the charged particles can be adiabatically transported during the dispe…
We present the technical details of a broadband microwave spectrometer for measuring the complex conductance of thin films covering the range from 50 MHz up to 16 GHz in the temperature range 300 mK to 6 K and at applied magnetic fields up to 8 Tesla. We measure the complex reflection from a sample terminating a coaxial transmission line and calibrate the signals with three standards with known reflection coefficients. Thermal isolation of the heat load from the inner conductor is accomplished by including a section of NbTi superconducting cable (transition temperature around 8 $-$ 9 K) and he…
We report a new design of resonant cavity for W-band EPR spectrometer. It suits with both solenoid-type and split-pair magnets. The cavity operates on the TE$_{011}$ mode, where the microwave magnetic field is along the cylindrical axis. Its cylindrical axis is horizontal, so the magnetic field of the microwave is always perpendicular to the vertical external magnetic field provided by a solenoid-type magnet. By rotating the cavity, the microwave magnetic field can also be perpendicular to a horizontal external field when a split-pair magnet is used. Furthermore, a tiny metal cylinder allows f…
The KATRIN experiment is a next-generation direct neutrino mass experiment with a sensitivity of 0.2 eV (90% C.L.) to the effective mass of the electron neutrino. It measures the tritium $β$-decay spectrum close to its endpoint with a spectrometer based on the MAC-E filter technique. The $β$-decay electrons are guided by a magnetic field that operates in the mT range in the central spectrometer volume; it is fine-tuned by a large-volume air coil system surrounding the spectrometer vessel. The purpose of the system is to provide optimal transmission properties for signal electrons and to achiev…
A novel design of high-voltage compatible polarimeter for spin-resolved hard x-ray photoelectron spectroscopy (Spin-HAXPES) went into operation at beamline BL09XU of SPring-8 in Hyogo, Japan. The detector is based on the well-established principle of electron diffraction from a W(001) single-crystal at a scattering energy of 103.5 eV. Its special feature is that it can be operated at a high negative bias potential up to 10 kV, necessary to access the HAXPES range. The polarimeter is operated behind a large hemispherical analyzer (Scienta R-4000). It was optimized for high transmission of the t…
I review latest results from AMS on electrons and positrons in primary cosmic rays in the GeV to TeV energy range. Separate fluxes for electrons and positrons as well as their sum are presented. Neither of the fluxes is compatible with a simple power law. New data on the fraction of positrons in the joint electron and positron flux are also presented, which extend the energy range of our previous observation and increase its precision. The new results show, for the first time, that above about 200 GeV the positron fraction no longer exhibits an increase with energy. The results confirm that a …
Continued improvement of the energy resolution of resonant inelastic x-ray scattering (RIXS) spectrometers is crucial for fulfilling the potential of this technique in the study of electron dynamics in materials of fundamental and technological importance. In particular, RIXS is the only alternative tool to inelastic neutron scattering capable of providing fully momentum resolved information on dynamic spin structures of magnetic materials, but is limited to systems whose magnetic excitation energy scales are comparable to the energy resolution. The state-of-the-art spherical diced crystal ana…
The method of direct neutrino mass determination based on the kinematics of tritium beta decay, which is adopted by the KATRIN experiment, makes use of a large, high-resolution electrostatic spectrometer with magnetic adiabatic collimation. In order to target a sensitivity on the neutrino mass of 0.2 eV/c^2, a detailed understanding of the electromagnetic properties of the electron spectrometer is essential, requiring comprehensive calibration measurements with dedicated electron sources. In this paper we report on a prototype of a photoelectron source providing a narrow energy spread and angu…
$^{229}$Th is the only known nucleus with an excited state that offers the possibility for a direct laser excitation using existing laser technology. Its excitation energy has been measured indirectly to be 7.8(5) eV ($\approx$160 nm). The energy and lifetime of the isomeric state make it the presently only suitable candidate for a nuclear optical clock, the uncertainty of the excitation energy is, however, still too large to allow for a direct laser excitation in a Paul trap. Therefore, a major goal during the past years has been an improved energy determination. One possible approach is to m…
There is a proposal to search for a sterile neutrino in a few keV mass range by the "Troitsk nu-mass" facility. In order to estimate sterile neutrino mixing one needs to make precision spectrum measurements well below the endpoint using the existing electrostatic spectrometer with a magnetic adiabatic collimation, or MAC-E filter. The expected signature will be a kink in the electron energy spectrum in tritium beta-decay. In this article we consider the systematic effect of electron backscattering on the detector used in the spectrometer. For this purpose we provide a set of Monte-Carlo simula…
Nowadays, there is an increasing demand for more accessible routine diagnostics for patients with respect to high accuracy, ease of use, and low cost. However, the quantitative and high accuracy bioassays in large hospitals and laboratories usually require trained technicians and equipment that is both bulky and expensive. In addition, the multi-step bioassays and long turnaround time could severely affect the disease surveillance and control especially in pandemics such as influenza and COVID-19. In view of this, a portable, quantitative bioassay device will be valuable in regions with scarce…
The KATRIN experiment is designed to determine the absolute neutrino mass scale with a sensitivity of 200 meV (90 % CL) by measuring the electron energy spectrum close to the endpoint of molecular tritium beta decay. Electrons from a high-intensity gaseous tritium source are guided by a strong magnetic field of a few T to the analyzing plane of the main spectrometer where an integral energy analysis takes place in a low field region (B<0.5 mT). An essential design feature to obtain adiabatic electron transport through this spectrometer is a large volume air coil system surrounding the vessel. …
The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magnetic field are attenuated by factors of 5 to 50 at a bandwidth from $10^{-3}$ Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the importan…
A magnetic spectrometer has been developed for the AWAKE experiment at CERN in order to measure the energy distribution of bunches of electrons accelerated in wakefields generated by proton bunches in plasma. AWAKE is a proof-of-principle experiment for proton-driven plasma wakefield acceleration, using proton bunches from the SPS. Electron bunches are accelerated to $\mathcal{O}$(1 GeV) in a rubidium plasma cell and then separated from the proton bunches via a dipole magnet. The dipole magnet also induces an energy-dependent spatial horizontal spread on the electron bunch which then impacts o…
An innovative approach: MSS - the Method of Spectra Superposition for high energy-resolution (Delta-E) studies on any accelerator of nuclear reactions at fixed targets by magnetic spectrometers, has been invented. For thin targets MSS provides a Delta-E which depends only on the detector's energy-resolution. The MSS can bring huge benefits to experiments with fixed targets at all types of accelerators and also on colliders. The MSS was used to get precise data with a Delta-E = 10 keV in (p,12C) elastic scattering for the energy region Ep 16 - 19.5 MeV at cyclotron U-150 of INP Ulugbek (Tashken…
In both particle physics and muon applications, a high-resolution muon momentum measurement capability plays a significant role not only in providing valuable information on the properties of subatomic particles but also in improving the utilizability of cosmic ray muons. Typically, muon momentum is measured by reconstructing a curved muon path using a strong magnetic field and muon trackers. Alternatively, a time-of-flight and Cherenkov ring imager are less frequently applied, especially when there is a need to avoid a magnetic field. However, measurement resolution is much less than that of …
Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To…
In both particle physics and cosmic ray muon applications, a high-resolution muon momentum measurement capability plays a significant role not only in providing valuable information on the properties of subatomic particles but also in improving the utilizability of muons. Currently, muon momentum is estimated by reconstructing the muon path using a strong magnetic field and muon trackers. Alternatively, time-of-flight or multiple Coulomb scattering techniques are less frequently applied, especially when there is a need to avoid using a magnetic field. However, the measurement resolution is muc…
The combination of a magnetic spectrometer and ancillary detectors such as silicon detectors is a powerful tool for the study of nuclear reactions and nuclear structure. This paper discusses the recently commissioned silicon array called the CAKE which is designed for use with the K600 magnetic spectrometer at iThemba LABS.
The generation of high frequency oscillatory magnetic fields represents a fundamental component underlying the successful implementation of neutron resonant spin-echo spectrometers, a class of instrumentation critical for the high-resolution extraction of dynamical excitations (structural and magnetic) in materials. In this paper, the setup of the resonant circuits at the longitudinal resonant spin-echo spectrometer RESEDA is described in comprehensive technical detail. We demonstrate that these circuits are capable of functioning at frequencies up to 3.6 MHz and over a broad bandwidth down to…
Cosmic ray muons have been considered as a non-conventional radiation probe in various applications. To utilize cosmic ray muons in engineering applications, two important quantities, trajectory and momentum, must be known. The muon trajectories are easily reconstructed using two-fold detector arrays with a high spatial resolution. However, precise measurement of muon momentum is difficult to be achieved without deploying large and expensive spectrometers such as solenoid magnets. Here, we propose a new method to estimate muon momentum using multi-layer pressurized gas Cherenkov radiators. Thi…