Gain, Rate and Position Resolution Limits of Micropattern Gaseous Detectors
V. Peskov, P. Fonte
备注:
10 pages, 3 figures, Presented at the PSD99-5th International Conference on Position-Sensitive Detectors, 13-17 th September 1999, University College, London
In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which depends on the size and design features, as well as on gas composition and pressure. However, in all cases the maximum achievable gain is less than or equal to the classical Raether limit. It also was found that for all detectors tested the maximum achievable gain drops sharply with the counting rate. The position resolution of micropattern detectors for detection of X-rays (6 to 35 kV) was also studied, being demonstrated that with solid converters one could reach a position resolution better than 30 micrometers at 1 atm in a simple counting mode.
This report summarizes the present knowledge on discharges in micropattern and small gap gaseous detectors and the physical mechanisms involved. These include the space-charge (Raether's) limit, rate-induced breakdown, cathode excitation effect and electron emission from the cathodes in the form of jets, inter-GEM breakdown in multistep configurations and finally surface streamers.
We have developed a cost effective technology for manufacturing various layouts of micropattern gaseous detectors for a wide range of applications. Such devices feature resistive electrodes interfaced to a network of thin readout strips/electrodes. The following three examples of such innovative designs and their applications will be presented: a prototype of a novel double-phase LAr detector with a CsI photocathode immersed inside the LAr, a CsI-RICH detector prototype for ALICE upgrade and GEM-like sensors for environmental safety/security applications.
In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures using only resistive coating. This allows a new device to be built with an architecture based on a stack of several coupled layers where drift and WELL multiplication stages alternate in the structure. The signals from each multiplication stage can be read out from any external readout boards through the capacitive couplings. Each layer provides a signal wit…
We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and spark protection property) with the high granularity and thus the good position resolution offered by microelectronic technology. In the stream of this activity, we have recently developed two novel detectors with resistive electrodes: one was based on resistive micromeshes and the second one is a MSGC with resistive electrodes. We have demonstrated that the r…
A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors have several important advantages over other conventional micropattern detectors and are unique for applications like the readout detectors for dual phase noble liquid TPCs and RICHs.
Operation results are presented of a UV-sensitive gaseous photomultiplier (GPM) coupled through a MgF2 window to a liquid-xenon scintillator. It consisted of a reflective CsI photocathode deposited on top of a THick Gaseous Electron Multiplier (THGEM); further multiplication stages were either a second THGEM or a Parallel Ionization Multiplier (PIM) followed by a MICROMEsh GAseous Structure (MICROMEGAS). The GPM operated in gas-flow mode with non-condensable gas mixtures. Gains of 10^4 were measured with a CsI-coated double-THGEM detector in Ne/CH4 (95:5), Ne/CF4 (95:5) and Ne/CH4/CF4 (90:5:5)…
The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 59 institutes from 20 countries bundle their effort, experience and resources to develop these emerging micropattern technologies. MPGDs are already employed in several nuclear and high-energy physics experiments, medical imaging instruments and photodetection applications; many more applications are foreseen. They outperform traditional wire chambers in terms of rate capability, time and position resolution, granularity, stability and radiation h…
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PIM) and a MICROMesh GAseous Structure (MICROMEGAS),operating in Ne/CF4 (90:10). Gain values close to 10^7 were recorded in this mixture, with 5.9keV x-rays at 1100 mbar, both at room temperature and at…
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for signal amplification in high background and/or low rate experiments due to their high electroluminescence yields and radiopurity. In this work, the VUV light responses of the Gas Electron Multiplier and …
We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a laser drilling technique. As in any other micropattern detectors the maximum achievable gas gain of these detectors is restricted by the Raether limit, however, the resistive mesh makes them and the front end electronics fully spark protected. This approach could be an alternative or complimentary to the ongoing efforts in developing MICROMEGAS and GEMs with res…
The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 75 institutes from 25 countries bundle their effort, experience and resources to develop these emerging micropattern technologies. MPGDs are already employed in several nuclear and high-energy physics experiments, medical imaging instruments and photodetection applications; many more applications are foreseen. They outperform traditional wire chambers in terms of rate capability, time and position resolution, granularity, stability and radiation h…
SILEM : a new gaseous detector with integrated x-y readout plane
本文报道了在EXO双β衰变实验框架内研制的气体探测器。LEM(Large Electron Multiplication)是基于GEM的电子放大栅极。它们是在纳沙泰尔开发的,对火花具有出色的抵抗力。新的SILEM网格将标准LEM的特性与网格一侧的微图案化x-y读出平面相结合。因此,它允许初级电子的放大和它们在x-y平面中的位置确定。
Nowadays RPCs are in a booming phase: they are successfully used in many experiments, including LHC; there are ambitious plans to use them in several upgrade detectors and in some new experiments as well as in various applications. The aim of this paper is to highlight the main challenges which the RPC community may face in the next few years and which were addressed in talks presented at this conference. Examples could be: new and difficult requirements from experiments (and their upgrades) and applications, optimization and improvements of the existing traditional detector designs, improveme…
Advances in the technologies associated with position sensitive gaseous detectors especially featuring CsI as reflective photoconverters will be reviewed. These photodetectors represent the most effective solution for what concerns cost and performance in the case of large area Cherenkov imaging applications in relatively low rate (or low occupancy) high energy physics and astrophysics experiments. Moreover, they are the only choice when the Cherenkov detector is embedded in a magnetic field. Recently proposed single photon MPGDs (Micropattern Gaseous Detectors) will be also discussed in view …
In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive GEM, resistive MICROMEGAS. These detectors combine in one design the best features of RPCs (spark-protection) and micropattern detectors (a high position resolution). In this paper we report the progress so far made in developing other types of resistive micropattern detectors: a microdot-microhole detector and a microgap-microstrip detector. The former detec…
We developed a tool for the simulation of charge transport on a conducting plate of finite dimensions. This tool is named Chani. Main motivation of developing Chani was to provide a tool for the optimization of the dimensions and resistivity of the anode electrodes in spark-protected Micropattern Gaseous Detectors (MPGD). In this thesis, we start with the general description of the LHC and the ATLAS Experiment. Then, we review the gaseous ionization detector technologies and in particular, the micromegas technology. We then present the working principles of Chani along with the example calcula…
The phenomenon of avalanche-gain variations over time, particularly in Micro Pattern Gaseous Detectors (MPGD) incorporating insulator materials, have been generally attributed to electric-field modifications resulting from "charging-up" effects of the insulator. A robust methodology for characterization of gain-transients in such detectors is presented. It comprises three guidelines: detector initialization, long-gain stabilization monitoring and imposing transients by applying abrupt changes in operation conditions. Using THWELL and RPWELL detectors, we validated the proposed methodology by a…
MicroPattern Gaseous Detectors (MPGD) made of resistive strips have raised as a promising technology for the protection against spark processes having place in the gaseous chamber. The reproduction of the signals and its propagation through the resistive foil is mandatory to better understand its behavior and optimize the key parameters which might depend on the application requirements. In this work it will be presented a resistive-strip model and the charge diffusion through the resistive strip for different model parameters, such as the strip linear resistivity and capacitance, together wit…
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the electron multiplier and the gaseous-photomultiplier operation and characterization in a continuous mode. We present results on the properties of laboratory-produced K$_2$CsSb, Cs$_3$Sb and Na$_2$KSb photoca…
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final avalanche charge was collected in a 2D strip readout, providing an active area of 10x10 cm2 for the entire detection system. For each mixture, the effective gain and energy resolution were measured as a function of the electric field in the drift, transfer and induction regions. Using X-rays from a 55Fe radioactive source (5.9 keV), gains close to 104 and energy…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In order to test the approximation experimentally, a setup involving a standard GEM layer has been constructed to measure the energy resolution for 5.9 keV gamma particles. The formula reasonably traces both the charge collection as well as the extraction process dependence of the energy resolution. Such analytic approximation for gain fluctuations can be applie…
Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Patterned Gaseous Detector category. GEMs are widely used in both nuclear and high energy experiments as well as in medical science. Several parameters define the performance of these types of devices under various experimental conditions. This article focuses on the study of effective gain and Ion Back Flow (IBF) in both triple and quadruple GEM detectors. Effective gain and IBF are two of the most important parameters in determining the performance of GEM detectors.
We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV x-ray in Ne/5%CH4; a minor 30% gain drop occurred with a rate increase from 10 to 10^4 Hz/mm^2. The detector displayed a full "discharge-free" operation--even when exposed to high primary ionization …
UV lasers for the calibration of gaseous detectors have seen newfound employment with current-generation micro-pattern gaseous detectors (MPGDs), especially those devices not suitable for tests with traditional sources (e.g. cosmic rays or X-ray beams) by design constraints. An apparatus made of a UV laser designed for the characterization of the fast timing MPGD (FTM) is here described, together with the measurements of gain curve and electron drift velocity performed on a prototype of Time Projection GEM (TPG) to validate the setup.
Micromegas detectors are a relatively modern design concept for micropattern gas detectors, designed to handle high particle flux while providing high gain, high spatial resolution, and fast response times for a variety of radiation detection applications. Due to the advancement of industry, building a micromegas detector without advanced in-house capabilities is now possible. In this work, we present an innovative method to build micromegas detectors utilizing precision manufacturers to fabricate the core components. Two detectors were built using the newly described method and are experiment…
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne an…
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the performance of GEMs. However, the gain prediction of GEMs that are manufactured with a double mask etching technique is not straightforward. With the hole size information alone, it is not possible to make precise prediction of the gain. We show that the alignment of the photo-masks between the two sides of the GEM foils plays a crucial role. A misalignment of a few…
Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI photocathode deposited on the first THGEM. A gain of $8\cdot10^{5}$ per photoelectron and $\sim100\%$ photoelectron collection efficiency are measured at stable operation settings. The excellent position resolution capabilities of the detector (better than 100 $μ$m) at 100 kHz readout rate, is demonstrated at room temperature. Structural integrity tests of the…
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency of greater than 95% is calculated, for operation of the detector over a 100V wide span of high voltages (HV). Over this same HV range, the background…
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at ave…
The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The preservation of spatial information from the initial ionizations was demonstrated by analyzing the light emission from 5.9keV X-rays of an 55Fe source. The observed non-uniformity of the scintillation…
The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) is presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it consists of a densely perforated assembly of multiple insulating substrate sheets (e.g., FR-4), sandwiched between thin metallic-electrode layers. The electron avalanche processes occur along the successive multiplication stages within the M-THGEM holes, under the action of strong dipole fields resulting from the application of suitable potential differences…
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a Micromegas detector. Both Micromegas and GEM have the capability to naturally reduce most of the ions produced in the amplification region. The GEM also acts as the preamplifer device and increases gas gain together with the Micromegas. Feasibility tests of the hybrid detector are performed using an ${}^{55}$Fe X-ray source. The energy resolution is better tha…
We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences applied between the various electrodes provide an efficient collection of ionization electrons within the MM-THGEM holes and a large charge avalanche multiplication between the meshes. Different from conventional hole-type multipliers (e.g. Gas Electron Multipliers - GEMs, Thick Gas Electron Multipliers - THGEMs, etc.), which are characterized by a variable (dip…
In gaseous tracking detectors with a large gaseous volume multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. We report on studies of effective gain, ion backflow (IBF), and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers.
With the development of the circular collider, it is necessary to make accurate physics experimental measurements of particle properties at higher luminosity $Z$ pole. Micro-pattern gaseous detectors (MPGDs), which contain Gaseous Electron Multiplier (GEM) and Micro-mesh gaseous structures (Micromegas), have excellent potential for development as the readout devices of the time projection chamber (TPC) tracker detector. To meet the updated physics requirements of the high luminosity $Z$ from the preliminary concept design report (preCDR) to concept design report (CDR) at the circular electron …