arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2604.20151cs.ROcs.LG
收藏

迈向安全的自主机器人内血管干预的世模型

Toward Safe Autonomous Robotic Endovascular Interventions using World Models

Surgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London(外科与介入工程系,生物医学工程与成像科学学院,伦敦国王学院);Department of Radiology, National Taiwan University Hospital(放射科,台湾大学医院);Department of Neuroradiology, King’s College Hospital(神经放射科,伦敦国王医院)

Harry Robertshaw, Nikola Fischer, Han-Ru Wu, Andrea Walker Perez, Weiyuan Deng, Benjamin Jackson, Christos Bergeles, Alejandro Granados, Thomas C Booth

AI总结:

本文提出基于世模型的框架,利用TD-MPC2方法在内血管导航中实现自主机械取栓,通过仿真和体外实验验证其在安全性和泛化性上的优势。

摘要:

自主机械取栓(MT)面临高度变化的血管几何和准确实时控制的挑战。尽管强化学习(RL)成为内血管导航自动化的有前景范式,但现有方法在面对多样的患者解剖或延长导航时间时表现出有限的鲁棒性。本文研究了一种基于世模型的框架,基于TD-MPC2,一种集成了规划和学习动态的模型驱动RL方法。我们评估了一个在多个导航任务上训练的TD-MPC2代理,在排除的患者特异性血管结构上进行测试,并将其性能与最先进的Soft Actor-Critic(SAC)算法代理进行比较。两种方法进一步在体外使用患者特异性血管假体在荧光引导下验证。在仿真中,TD-MPC2的平均成功率显著高于SAC(58% vs. 36%,p < 0.001),平均尖端接触力为0.15 N,远低于提议的1.5 N血管破裂阈值。TD-MPC2的平均成功率(68%)与SAC(60%)在体外相当,但TD-MPC2在路径比率(p = 0.017)上表现更优,但耗时更长(p < 0.001)。这些结果首次在排除的in silico数据和荧光引导的in vitro实验中验证了自主MT导航,突显了世模型在安全和可推广的AI辅助内血管干预中的潜力。

英文摘要:

Autonomous mechanical thrombectomy (MT) presents substantial challenges due to highly variable vascular geometries and the requirements for accurate, real-time control. While reinforcement learning (RL) has emerged as a promising paradigm for the automation of endovascular navigation, existing approaches often show limited robustness when faced with diverse patient anatomies or extended navigation horizons. In this work, we investigate a world-model-based framework for autonomous endovascular navigation built on TD-MPC2, a model-based RL method that integrates planning and learned dynamics. We evaluate a TD-MPC2 agent trained on multiple navigation tasks across hold out patient-specific vasculatures and benchmark its performance against the state-of-the-art Soft Actor-Critic (SAC) algorithm agent. Both approaches are further validated in vitro using patient-specific vascular phantoms under fluoroscopic guidance. In simulation, TD-MPC2 demonstrates a significantly higher mean success rate than SAC (58% vs. 36%, p < 0.001), and mean tip contact forces of 0.15 N, well below the proposed 1.5 N vessel rupture threshold. Mean success rates for TD-MPC2 (68%) were comparable to SAC (60%) in vitro, but TD-MPC2 achieved superior path ratios (p = 0.017) at the cost of longer procedure times (p < 0.001). Together, these results provide the first demonstration of autonomous MT navigation validated across both hold out in silico data and fluoroscopy-guided in vitro experiments, highlighting the promise of world models for safe and generalizable AI-assisted endovascular interventions.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑