Department of Control Science and Engineering, College of Electronics and Information Engineering, and Shanghai Institute of Intelligent Science and Technology, Tongji University(控制科学与工程系,电子与信息工程学院和智能科学与技术上海研究院,同济大学);Department of Electronic Engineering, Faculty of Engineering, The Chinese University of Hong Kong(电子工程系,工程学院,香港中文大学);Shanghai Operation Robot Co., Ltd.(上海操作机器人有限公司);Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, National Clinical Research Center for Interventional Medicine(心内科,复旦大学中山医院,上海心血管疾病研究所,介入医学临床研究中心);State Key Laboratory of Cardiovascular Diseases and Medical Innovation Center, Shanghai East Hospital, School of Medicine, Tongji University(心血管疾病国家重点实验室和医学创新中心,上海东医院,同济大学医学院)

Jiyuan Zhao, Zhengyu Shi, Wentong Tian, Tianliang Yao, Dong Liu, Tao Liu, Yizhe Wu, Peng Qi

AI总结:

本文提出SCAR-UNet-GAT框架,通过拓扑编码图实现机器人辅助血管内导航中的路径解歧,显著提升路径规划的准确性和鲁棒性。

摘要:

机器人辅助经皮冠状动脉介入治疗(PCI)受到二维数字减影血管造影(DSA)固有局限性的制约。与医生能够直接操控导丝并结合触觉反馈与先验解剖知识不同,远程操作的机器人系统必须仅依赖二维投影。这种操作模式同时缺乏空间上下文和触觉感觉,可能导致在血管分叉处出现投影诱导的歧义。为解决这一挑战,我们提出了一种两阶段框架(SCAR-UNet-GAT)用于实时机器人路径规划。在第一阶段,SCAR-UNet,一种空间坐标注意力正则化的U-Net,用于准确分割冠状动脉血管。多级注意力机制的整合增强了对细长、蜿蜒血管的勾勒,并提高了对成像噪声的鲁棒性。从得到的二值掩码中提取血管中心线和分叉点,并将几何描述符(例如,分支直径、交角)与局部DSA补丁融合以构建节点特征。在第二阶段,图注意力网络(GAT)对血管图进行推理,以识别解剖学一致且临床可行的轨迹,有效区分真正的分叉与投影诱导的假交叉。在临床DSA数据集上,SCAR-UNet实现了Dice系数为93.1%。对于路径解歧,所提出的基于GAT的方法达到了95.0%的成功率和90.0%的目标到达成功率,显著优于传统最短路径规划(60.0%和55.0%)和基于启发式的规划(75.0%和70.0%)。在机器人平台上的验证进一步确认了所提出框架的实用可行性和鲁棒性。

英文摘要:

Robotic-assisted percutaneous coronary intervention (PCI) is constrained by the inherent limitations of 2D Digital Subtraction Angiography (DSA). Unlike physicians, who can directly manipulate guidewires and integrate tactile feedback with their prior anatomical knowledge, teleoperated robotic systems must rely solely on 2D projections. This mode of operation, simultaneously lacking spatial context and tactile sensation, may give rise to projection-induced ambiguities at vascular bifurcations. To address this challenge, we propose a two-stage framework (SCAR-UNet-GAT) for real-time robotic path planning. In the first stage, SCAR-UNet, a spatial-coordinate-attention-regularized U-Net, is employed for accurate coronary vessel segmentation. The integration of multi-level attention mechanisms enhances the delineation of thin, tortuous vessels and improves robustness against imaging noise. From the resulting binary masks, vessel centerlines and bifurcation points are extracted, and geometric descriptors (e.g., branch diameter, intersection angles) are fused with local DSA patches to construct node features. In the second stage, a Graph Attention Network (GAT) reasons over the vessel graph to identify anatomically consistent and clinically feasible trajectories, effectively distinguishing true bifurcations from projection-induced false crossings. On a clinical DSA dataset, SCAR-UNet achieved a Dice coefficient of 93.1%. For path disambiguation, the proposed GAT-based method attained a success rate of 95.0% and a target-arrival success rate of 90.0%, substantially outperforming conventional shortest-path planning (60.0% and 55.0%) and heuristic-based planning (75.0% and 70.0%). Validation on a robotic platform further confirmed the practical feasibility and robustness of the proposed framework.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑