arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.12917physics.med-phcs.AI
收藏

超声引导的实时脊柱运动可视化用于脊柱不稳定评估

Ultrasound-Guided Real-Time Spinal Motion Visualization for Spinal Instability Assessment

Chair for Computer Aided Medical Procedures and Augmented Reality(计算机辅助医疗程序与增强现实主席职位);Technical University of Munich(慕尼黑技术大学);Munich Center for Machine Learning (MCML)(慕尼黑机器学习中心);University of Hong Kong(香港大学)

Feng Li, Yuan Bi, Tianyu Song, Zhongliang Jiang, Nassir Navab

AI总结:

本研究提出利用机器人超声与CBCT结合,实现低辐射的实时3D脊柱运动可视化,用于评估脊柱不稳定。

摘要:

目的:脊柱不稳定是一种常见的疾病,会导致疼痛、疲劳和活动受限,严重影响患者的生活质量。在临床实践中,诊断的金标准是动态X射线成像。然而,X射线只能提供2D的运动信息,而CT或锥形束CT等3D模态无法有效捕捉运动。因此,需要一种能够实时可视化3D脊柱运动并减少辐射暴露的系统。方法:我们提出将超声作为辅助模态用于3D脊柱可视化。由于声学限制,超声只能捕捉表层脊柱表面。因此,部分合成的超声体积被注册到术前3D成像中。在本研究中,CBCT提供中性脊柱配置,而机器人超声采集在最大脊柱弯曲时进行。应用运动学模型到CBCT衍生的脊柱模型进行粗注册,随后使用ICP进行精细注册,运动学参数基于注册结果进行优化。实时超声运动追踪用于通过中性与最大弯曲状态之间的插值来估计连续的3D脊柱运动。结果:该流程在可弯曲的3D打印腰椎假体上进行了评估。注册误差为1.941±0.199毫米,插值脊柱运动误差为2.01±0.309毫米(中位数)。结论:所提出的机器人超声框架能够实现减少辐射的实时3D脊柱运动可视化,为评估脊柱不稳定提供了有前景的3D替代方案,替代传统的动态X射线成像。

英文摘要:

Purpose: Spinal instability is a widespread condition that causes pain, fatigue, and restricted mobility, profoundly affecting patients' quality of life. In clinical practice, the gold standard for diagnosis is dynamic X-ray imaging. However, X-ray provides only 2D motion information, while 3D modalities such as computed tomography (CT) or cone beam computed tomography (CBCT) cannot efficiently capture motion. Therefore, there is a need for a system capable of visualizing real-time 3D spinal motion while minimizing radiation exposure. Methods: We propose ultrasound as an auxiliary modality for 3D spine visualization. Due to acoustic limitations, ultrasound captures only the superficial spinal surface. Therefore, the partially compounded ultrasound volume is registered to preoperative 3D imaging. In this study, CBCT provides the neutral spine configuration, while robotic ultrasound acquisition is performed at maximal spinal bending. A kinematic model is applied to the CBCT-derived spine model for coarse registration, followed by ICP for fine registration, with kinematic parameters optimized based on the registration results. Real-time ultrasound motion tracking is then used to estimate continuous 3D spinal motion by interpolating between the neutral and maximally bent states. Results: The pipeline was evaluated on a bendable 3D-printed lumbar spine phantom. The registration error was $1.941 \pm 0.199$ mm and the interpolated spinal motion error was $2.01 \pm 0.309$ mm (median). Conclusion: The proposed robotic ultrasound framework enables radiation-reduced, real-time 3D visualization of spinal motion, offering a promising 3D alternative to conventional dynamic X-ray imaging for assessing spinal instability.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑