arXiv 2602.03795physics.ins-det
收藏

ATLAS MDT TDC模拟用于LHC运行3和HL-LHC

ATLAS MDT TDC Simulations for LHC Run3 and HL-LHC

University of Michigan(密歇根大学);Shandong University(山东大学);Max-Planck-Institut für Physik, Werner Heisenberg Institute(马克斯·普朗克物理研究所,维尔纳·海森堡研究所)

Jiajin Ge, Bing Li, Markus Fras, Junjie Zhu, Bing Zhou, Tiesheng Dai

AI总结:

本文通过模拟ATLAS MDT TDC芯片在高亮度运行下的性能,验证其在运行3及HL-LHC条件下的可行性。

摘要:

大型强子对撞机(LHC)于2022年开始运行3期运行,运行3期的峰值瞬时亮度可能达到3×10^34 cm-2s-1。ATLAS监控漂移管(MDT)腔体是ATLAS缪子探测器中精度跟踪系统的主要组成部分。了解MDT前端(FE)读出电子设备在预期的水平1(L1)触发率100 kHz和复杂死时间超过5%的运行3期运行中可能存在的任何问题很重要。我们使用2022年收集的原始数据来模拟MDT腔体中预期的击中率,并使用当前配置对ATLAS缪子TDC(时间到数字转换器)(AMT)芯片进行现实模拟。我们通过使用Modelsim软件分析触发/L1/读出缓冲区占用和击中丢失分数,在不同的亮度下研究AMT芯片的性能,L1速率为100 kHz。由于FE读出,最热的MDT腔体(BIL3C05)的击中丢失分数低于5%,即使在亮度为5.01×10^34 cm-2s-1、死时间为5%、L1速率为100 kHz的情况下,表明AMT可以在运行3期条件下正常工作。MDT触发和读出电子设备将在高亮度LHC(HL-LHC)运行期间被替换为无触发读出。我们还模拟了AMT在无触发模式下的行为,最高达到7.44×10^34 cm-2s-1,并提出了可能的AMT配置,以防在长停机3(LS3)期间某些FE电子设备无法被替换。

英文摘要:

The Large Hadron Collider (LHC) started the Run 3 operation in 2022, and the peak instantaneous luminosity in Run 3 may reach 3 x 10^34 cm-2s-1. The ATLAS Monitored Drift Tube (MDT) chambers are the main component of the precision tracking system in the ATLAS muon spectrometer. It is important to understand any potential issues with the MDT Front-End (FE) readout electronics for an expected level-1 (L1) trigger rate of 100 kHz and a complex deadtime of over 5% for Run 3 operations. We use raw data collected in 2022 to emulate the expected hit rates in MDT chambers and perform a realistic simulation on the ATLAS Muon TDC (Time-to-Digital Converter) (AMT) chip with the current configuration. We study the AMT chip performances by analyzing the trigger/L1/readout buffer occupancies and hit loss fractions under different luminosities with L1 rate of 100 kHz by using the Modelsim software. The hit loss fraction of the hottest MDT chamber (BIL3C05) is lower than 5% due to FE readout, even at a luminosity of 5.01 x 10^34 cm-2s-1 with a deadtime of 5% and a L1 rate of 100 kHz, indicating that AMT can operate under Run 3 conditions without problems. The MDT trigger and readout electronics will be replaced for triggerless readout during High-Luminosity LHC (HL-LHC) runs. We also simulate the AMT behavior in the triggerless mode up to 7.44 x 10^34 cm-2s-1 and propose possible AMT configurations in case some FE electronics could not be replaced during the long shutdown 3 (LS3).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑