Temperature Studies for ATLAS MDT BOS Chambers

A. Engl, O. Biebel, R. Hertenberger, R. Mameghani, D. Merkl, F. Rauscher, D. Schaile, R. Stroehmer

摘要:

在宇宙射线设施,配备了3个ATLAS BOS MDT室,在Garching(慕尼黑)的数据集与高的统计数据已被用来研究气体增益和漂移时间的温度和压力的影响。使用内部RasNik对准监测系统和来自宇宙数据的轨道重建了热膨胀室的变形。对于这些研究,加热系统被设计成将中间室的温度增加至室温以上20开尔文。为了比较,温度对气体性质的影响已经用Garfield进行了模拟。最大漂移时间随温度的升高而减小,减小幅度为-2.21 ± 0.08ns/K,与压力变化和Garfield模拟的结果一致。温度升高导致气体增益线性增加约2.1%1/K。利用重建的轨迹分析了药室的变形。通过对比参考室和试验室的轨迹,重建了热膨胀,结果与理论膨胀系数一致。由于导线固定在腔室的末端,因此导线位置计算无法提供腔室中部的结论。监测系统RasNik的分析已经确定了完整的变形,其测量值显示了整个腔室的均匀膨胀,由腔室中部相对于腔室外部的移位和旋转所覆盖。两种方法的测定结果基本一致。我们也提出了一个作为温度函数的位置漂移时间校正模型。

英文摘要:

Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber the thermal expansion has been reconstructed and the result shows agreement with the theoretical expansion coefficient. As the wires are fixed at the end of the chamber, the wire position calculation can not provide a conclusion for the chamber middle. The complete deformation has been identified with the analysis of the monitoring system RasNik, whose measured values have shown a homogeneous expansion of the whole chamber, overlayed by a shift and a rotation of the chamber middle with respect to the outer part of the chamber. The established results of both methods are in agreement. We present as well a model for the position-drifttime correction as function of temperature.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑