移动光束衍射几何:DIAD 对衍射扫描探针的应用

The Moving Beam Diffraction Geometry: the DIAD Application of a Diffraction Scanning-Probe

Diamond Light Source(钻石光源);The University of Manchester(曼彻斯特大学);National Synchrotron Light Source II, Brookhaven National Laboratory(美国国家同步辐射光源二号,布鲁海文国家实验室);University of Basel(巴塞尔大学)

Alberto Leonardi, Andrew James, Christina Reinhard, Michael Drakopoulos, Ben Williams, Hans Dehyle, Jacob Filik, Liam Perera, Sharif Ahmed

AI总结:

本文提出 DIAD 光束线的移动光束衍射几何方法,通过扫描微米级衍射光束实现图像引导衍射,并验证其校准与数据还原精度可达 0.0001 以下,适用于快速演化样品研究。

摘要:

理解微观结构、应变、相态与材料行为之间的相互作用在许多科学领域中至关重要。然而,量化这些相关性具有挑战性,因为这需要使用多种仪器和技术,而这些仪器和技术往往在空间和时间上相互分离。Diamond 光源的双成像与衍射(DIAD)光束线正是为应对这一挑战而设计的。DIAD 使用户能够可视化内部结构、识别成分/相变并测量应变。DIAD 提供两束独立光束并在同一样品位置汇合,从而能够准同时进行 X 射线计算机断层扫描和 X 射线粉末衍射。DIAD 配置的一项独特功能是能够执行图像引导衍射,即在不移动样品的情况下,让微米级衍射光束扫描成像视场的整个区域。这种移动光束衍射几何结构使得研究快速演化和易受运动影响的过程与样品成为可能。本文讨论了新颖的移动光束衍射几何结构,并介绍了关于所用几何校准与数据还原流程可靠性的最新发现。我们的测量证实,对于位于入射光束下游法线方向的探测器位置,衍射对移动几何结构最为敏感。观测数据证实,KB 镜与固定孔径狭缝耦合运动会导致光束探针发生刚性平移,而不会改变入射光束路径到达样品的角度。我们的测量表明,当校准样品区域与被探测样品区域之间的距离小于或等于光束光斑尺寸时,最近邻校准可以达到与自校准几何结构相同的精度。我们证明移动光束衍射几何结构的绝对误差保持在 0.0001 以下,这与我们在光束线稳定运行时所观测到的精度一致。

英文摘要:

Understanding the interactions between microstructure, strain, phase, and material behavior is crucial in many scientific fields. However, quantifying these correlations is challenging, as it requires the use of multiple instruments and techniques, often separated by space and time. The Dual Imaging And Diffraction (DIAD) beamline at Diamond is designed to address this challenge. DIAD allows its users to visualize internal structures, identify compositional/phase changes, and measure strain. DIAD provides two independent beams combined at one sample position, allowing quasi-simultaneous X-ray Computed Tomography and X-ray Powder Diffraction. A unique functionality of the DIAD configuration is the ability to perform image-guided diffraction, where the micron-sized diffraction beam is scanned over the complete area of the imaging field of view without moving the specimen. This moving beam diffraction geometry enables the study of fast-evolving and motion-susceptible processes and samples. Here, we discuss the novel moving beam diffraction geometry presenting the latest findings on the reliability of both geometry calibration and data reduction routines used. Our measures confirm diffraction is most sensitive to the moving geometry for the detector position downstream normal to the incident beam. The observed data confirm that the motion of the KB mirror coupled with a fixed aperture slit results in a rigid translation of the beam probe, without affecting the angle of the incident beam path to the sample. Our measures demonstrate a nearest-neighbour calibration can achieve the same accuracy as a self-calibrated geometry when the distance between calibrated and probed sample region is smaller or equal to the beam spot size. We show the absolute error of the moving beam diffraction geometry remains below 0.0001, which is the accuracy we observe for the beamline with stable beam operation.