用于腹部CT形变图像配准(DIR)验证的血管分叉标志点对数据集

A Vessel Bifurcation Landmark Pair Dataset for Abdominal CT Deformable Image Registration (DIR) Validation

Duke University(杜克大学);Washington University School of Medicine(华盛顿大学医学院)

Edward R Criscuolo, Yao Hao, Zhendong Zhang, Trevor McKeown, Deshan Yang

AI总结:

本研究构建了首个腹部CT DIR验证专用的血管分叉高精度标志点对数据集,含30例共1895对标志点,精度达0.7±1.2mm,可为DIR算法开发提供更可靠的质量验证基准。

摘要:

形变图像配准(Deformable Image Registration, DIR)是众多诊断与治疗任务中的支撑技术。尽管如此,DIR算法的临床应用仍十分有限,主要原因是缺乏开发过程中用于质量保证的基准数据集。为支撑未来的算法开发,本文推出了首个腹部CT DIR基准数据集,该数据集包含大量位于匹配血管分叉处的高精度标志点对。\n研究从多个公共数据库及经机构审查委员会(IRB)批准的作者所在机构,采集了30名患者的腹部CT图像对。每对中的两张CT图像均为同一名患者在不同日期采集所得。研究开发了一套图像处理工作流并应用于每对图像:1)采用深度学习模型分割腹部器官,并覆盖器官掩码内的图像灰度值;2)在每对CT图像之间手动识别匹配的图像块;3)在每个图像块对的其中一张图像上标注血管分叉标志点;4)对图像块进行形变配准,并将标志点投影到第二张图像上;5)通过手动或自动化流程优化标志点对的位置。\n该工作流共生成1895个标志点对,平均每个病例63个。采用数字体模评估的标志点对精度为0.7±1.2mm。数据集已发布于Zenodo,网址为https://doi.org/10.5281/zenodo.14362785,使用说明可参见https://github.com/deshanyang/Abdominal-DIR-QA。该数据集是首个用于腹部DIR验证的专用数据集,其标志点对的数量、精度与分布特性,可实现对DIR算法的鲁棒验证,且精度优于现有可用方案。

英文摘要:

Deformable image registration (DIR) is an enabling technology in many diagnostic and therapeutic tasks. Despite this, DIR algorithms have limited clinical use, largely due to a lack of benchmark datasets for quality assurance during development. To support future algorithm development, here we introduce our first-of-its-kind abdominal CT DIR benchmark dataset, comprising large numbers of highly accurate landmark pairs on matching blood vessel bifurcations. Abdominal CT image pairs of 30 patients were acquired from several public repositories as well as the authors' institution with IRB approval. The two CTs of each pair were originally acquired for the same patient on different days. An image processing workflow was developed and applied to each image pair: 1) Abdominal organs were segmented with a deep learning model, and image intensity within organ masks was overwritten. 2) Matching image patches were manually identified between two CTs of each image pair 3) Vessel bifurcation landmarks were labeled on one image of each image patch pair. 4) Image patches were deformably registered, and landmarks were projected onto the second image. 5) Landmark pair locations were refined manually or with an automated process. This workflow resulted in 1895 total landmark pairs, or 63 per case on average. Estimates of the landmark pair accuracy using digital phantoms were 0.7+/-1.2mm. The data is published in Zenodo at https://doi.org/10.5281/zenodo.14362785. Instructions for use can be found at https://github.com/deshanyang/Abdominal-DIR-QA. This dataset is a first-of-its-kind for abdominal DIR validation. The number, accuracy, and distribution of landmark pairs will allow for robust validation of DIR algorithms with precision beyond what is currently available.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑