血压波形的测量正成为一个越来越频繁被研究的领域。传感器技术的发展开辟了许多能够测量高质量信号的新途径。开发这种面向特定目标的传感器可能耗时、昂贵,并且难以使用已知且一致的波形进行测试或验证。在本文中,我们提出了一种开源血压波形模拟器,并配有一个开源的 Python 验证包,以降低早期传感器开发和研究的成本。该模拟器主要由 3D 打印部件组成,这种技术已成为一种广泛可用且廉价的解决方案。模拟器的核心部件是一个 3D 打印的凸轮,该凸轮可以基于真实血压波形生成。该验证框架能够在用于设计凸轮的信号波形与被验证传感器测得的时序信号之间建立详细的比较。所提出的模拟器在短期和长期使用中均被证明是稳健且准确的,因为它能够一致且准确地产生信号波形。为了验证该解决方案,使用了一个 3D 力传感器,该传感器此前已被证明能够在手腕桡动脉处测量高质量的血压波形。结果显示,测量波形与标称波形之间具有很高的相似性,这意味着在比较归一化信号时,RMSE 值范围为 0.0276 ± 0.0047 至 0.0212 ± 0.0023,Pearson 相关系数范围为 0.9933 ± 0.0027 至 0.9978 ± 0.0005。我们的验证框架可在 https://github.com/repat8/cam-bpw-sim 获取。我们的硬件框架可在 https://github.com/repat8/cam-bpw-sim-hardware 获取,该框架允许复现所提出的解决方案。整个设计是一个开源项目,并使用自由软件开发。
英文摘要:
Measuring the blood pressure waveform is becoming a more frequently studied area. The development of sensor technologies opens many new ways to be able to measure high-quality signals. The development of such an aim-specific sensor can be time-consuming, expensive, and difficult to test or validate with known and consistent waveforms. In this paper, we present an open source blood pressure waveform simulator with an open source Python validation package to reduce development costs for early-stage sensor development and research. The simulator mainly consists of 3D printed parts which technology has become a widely available and cheap solution. The core part of the simulator is a 3D printed cam that can be generated based on real blood pressure waveforms. The validation framework can create a detailed comparison between the signal waveform used to design the cam and the measured time series from the sensor being validated. The presented simulator proved to be robust and accurate in short- and long-term use, as it produced the signal waveform consistently and accurately. To validate this solution, a 3D force sensor was used, which was proven earlier to be able to measure high-quality blood pressure waveforms on the radial artery at the wrist. The results showed high similarity between the measured and the nominal waveforms, meaning that comparing the normalized signals, the RMSE value ranged from $0.0276 \pm 0.0047$ to $0.0212 \pm 0.0023$, and the Pearson correlation ranged from $0.9933 \pm 0.0027$ to $0.9978 \pm 0.0005$. Our validation framework is available at https://github.com/repat8/cam-bpw-sim. Our hardware framework, which allows reproduction of the presented solution, is available at https://github.com/repat8/cam-bpw-sim-hardware. The entire design is an open source project and was developed using free software.
A robust and versatile deep learning model for prediction of the arterial input function in dynamic small animal $\left[^{18}\text{F}\right]$FDG PET imaging
Department of Physics and Technology, UiT The Arctic University of Norway(物理与技术系,UiT 北极大学)
Arterial blood pressure waveform in liver transplant surgery possesses variability of morphology reflecting recipients' acuity and predicting short term outcomes
Taipei Veterans General Hospital(台北荣民总医院);National Yang Ming Chiao Tung University(国立阳明交通大学);Duke University(杜克大学)
In Vivo Quantification of Arterial Active Mechanics Using Deep Learning-Assisted Pressure-Area Analysis
Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics, Tsinghua University(清华大学工程力学系,水沙科学与水利水电工程国家重点实验室,生物力学与医学工程系)
Superparamagnetic iron oxide polyacrylic acid coated γ-Fe2O3 nanoparticles does not affect kidney function but causes acute effect on the cardiovascular function in healthy mice
本研究描述了静脉注射聚丙烯酸(PAA)涂层γ-Fe 2 O3纳米粒(10 mg kg-1)在健康BALB/cJ小鼠器官、细胞和亚细胞水平的分布,并平行讨论了纳米粒注射对肾功能、血压和血管收缩力的影响。磁共振成像(MRI)和透射电子显微镜(TEM)显示,静脉输注后1小时内,NPs在肝脏中蓄积,通过内皮细胞和枯否细胞的细胞内摄取调节,随后在肾细胞,特别是近端小管的细胞质,足细胞和系膜细胞中的细胞内摄取调节。通过动脉酸碱状态和长期留置导管后测量肾小球滤过率(GFR)来评价NP对肾功能的影响。注射生理盐水或NP后0.5 h,小鼠动脉pH值分别为7.46和7.41,在接下来的12 h内没有变化。此外,注射NP也不影响动脉PCO 2或[HCO 3-]。NP注射后24小时和96小时,GFR平均值分别为11.0和13.0 ml min-1 g-1,与对照组(14.0和14.0 ml min-1 g-1)具有统计学可比性。NP注射后12- 24小时平均动脉血压(MAP)降低(111 vs 123 min-1),与肠系膜小动脉收缩力降低相关,通过肌造影显示肠系膜小动脉收缩力降低,从而降低内皮功能。总之,我们的研究表明,超顺磁性氧化铁纳米颗粒的积累不会影响健康小鼠的肾功能,但会暂时降低血压。
Machine-Learning Identification of Hemodynamics in Coronary Arteries in the Presence of Stenosis
Babol Noshirvani University of Technology(巴博勒努希尔瓦尼技术大学);Italian Institute of Technology(意大利技术研究院);Royan Institute for Stem Cell Biology and Technology(罗扬干细胞生物学与技术研究所);Sharif University of Technology(谢里夫理工大学)
Real-time diffuse correlation spectroscopy with a chip-based correlator for measuring human cerebral blood flow and brain function
University of Strathclyde(斯特拉斯克莱德大学);Faculty of Health Sciences, University of Macau(澳门科技大学);The University of Edinburgh(爱丁堡大学);Zhuhai UM Science and Technology Research Institute, University of Macau(澳门大学珠海研究院);Centre for Cognitive and Brain Sciences, University of Macau(澳门大学认知与脑科学中心);A*STAR Skin Research Labs (A*SRL), Agency for Science, Technology and Research (A*STAR)(新加坡科技研究局皮肤研究实验室)