arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2501.07973physics.med-phcs.SYeess.SY
收藏

一种用于连续动脉血压测量传感器的开源验证系统

An Open Source Validation System for Continuous Arterial Blood Pressure Measuring Sensors

Attila Répai, Sándor Földi, Péter Sótonyi, György Cserey

AI总结:

本文提出一种基于3D打印凸轮的开源血压波形模拟器及Python验证包,以降低连续动脉血压传感器早期开发与验证成本,实验证明其模拟波形与标称波形高度一致。

摘要:

血压波形的测量正成为一个越来越频繁被研究的领域。传感器技术的发展开辟了许多能够测量高质量信号的新途径。开发这种面向特定目标的传感器可能耗时、昂贵,并且难以使用已知且一致的波形进行测试或验证。在本文中,我们提出了一种开源血压波形模拟器,并配有一个开源的 Python 验证包,以降低早期传感器开发和研究的成本。该模拟器主要由 3D 打印部件组成,这种技术已成为一种广泛可用且廉价的解决方案。模拟器的核心部件是一个 3D 打印的凸轮,该凸轮可以基于真实血压波形生成。该验证框架能够在用于设计凸轮的信号波形与被验证传感器测得的时序信号之间建立详细的比较。所提出的模拟器在短期和长期使用中均被证明是稳健且准确的,因为它能够一致且准确地产生信号波形。为了验证该解决方案,使用了一个 3D 力传感器,该传感器此前已被证明能够在手腕桡动脉处测量高质量的血压波形。结果显示,测量波形与标称波形之间具有很高的相似性,这意味着在比较归一化信号时,RMSE 值范围为 0.0276 ± 0.0047 至 0.0212 ± 0.0023,Pearson 相关系数范围为 0.9933 ± 0.0027 至 0.9978 ± 0.0005。我们的验证框架可在 https://github.com/repat8/cam-bpw-sim 获取。我们的硬件框架可在 https://github.com/repat8/cam-bpw-sim-hardware 获取,该框架允许复现所提出的解决方案。整个设计是一个开源项目,并使用自由软件开发。

英文摘要:

Measuring the blood pressure waveform is becoming a more frequently studied area. The development of sensor technologies opens many new ways to be able to measure high-quality signals. The development of such an aim-specific sensor can be time-consuming, expensive, and difficult to test or validate with known and consistent waveforms. In this paper, we present an open source blood pressure waveform simulator with an open source Python validation package to reduce development costs for early-stage sensor development and research. The simulator mainly consists of 3D printed parts which technology has become a widely available and cheap solution. The core part of the simulator is a 3D printed cam that can be generated based on real blood pressure waveforms. The validation framework can create a detailed comparison between the signal waveform used to design the cam and the measured time series from the sensor being validated. The presented simulator proved to be robust and accurate in short- and long-term use, as it produced the signal waveform consistently and accurately. To validate this solution, a 3D force sensor was used, which was proven earlier to be able to measure high-quality blood pressure waveforms on the radial artery at the wrist. The results showed high similarity between the measured and the nominal waveforms, meaning that comparing the normalized signals, the RMSE value ranged from $0.0276 \pm 0.0047$ to $0.0212 \pm 0.0023$, and the Pearson correlation ranged from $0.9933 \pm 0.0027$ to $0.9978 \pm 0.0005$. Our validation framework is available at https://github.com/repat8/cam-bpw-sim. Our hardware framework, which allows reproduction of the presented solution, is available at https://github.com/repat8/cam-bpw-sim-hardware. The entire design is an open source project and was developed using free software.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑