arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2411.07503eess.IVcs.CVcs.LGphysics.med-phq-bio.TO

一种基于增强型跟踪-学习-检测框架与自动分割的MRI引导放疗中新型自动实时运动跟踪方法

A Novel Automatic Real-time Motion Tracking Method in MRI-guided Radiotherapy Using Enhanced Tracking-Learning-Detection Framework with Automatic Segmentation

Beijing University of Posts and Telecommunications(北京邮电大学);National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College(国家癌症中心/国家癌症临床医学研究中心/中国医学科学院北京协和医学院肿瘤医院)

Shengqi Chen, Zilin Wang, Jianrong Dai, Shirui Qin, Ying Cao, Ruiao Zhao, Jiayun Chen, Guohua Wu, Yuan Tang

AI总结:

本文提出ETLD+ICV方法,将增强型跟踪-学习-检测框架与改进Chan-Vese模型结合,实现MRI引导放疗中自动实时无标记运动跟踪与分割,在肝转移患者数据上取得亚毫米跟踪精度和高Dice得分。

摘要:

背景与目的:在MRI引导放疗(MRIgRT)中,精确的运动跟踪对于有效实施治疗至关重要。本研究旨在通过一种采用增强型跟踪-学习-检测(ETLD)框架并结合自动分割的自动实时无标记跟踪方法,提高MRIgRT中的运动跟踪精度。材料与方法:我们通过将ETLD框架与改进的Chan-Vese模型(ICV)相集成,开发了一种新型的MRIgRT运动跟踪与分割方法,命名为ETLD+ICV。ETLD框架针对实时电影MRI进行了升级,包括先进的图像预处理、无参考图像质量评估、增强型中值流跟踪器以及具有动态搜索区域调整能力的精化检测器。ICV用于实现精确的靶区覆盖,利用跟踪结果逐帧细化分割区域,并对关键参数进行了优化。该方法在来自10例肝转移患者的3.5D MRI扫描数据上进行了测试。结果:对77个治疗分次中的106,000帧图像进行的评估显示,在射束眼视图(BEV)/射束路径视图(BPV)方向上,所有受试者的跟踪误差均小于0.8mm,达到亚毫米级,精确率超过99%,召回率超过98%。ETLD+ICV方法在所有受试者中均取得了超过82%的Dice全局得分,证明了该方法的可扩展性和精确的靶区覆盖能力。结论:本研究成功开发了一种用于MRIgRT的自动实时无标记运动跟踪方法,其性能显著优于现有方法。该新型方法不仅在跟踪和分割方面提供了卓越的精度,还表现出对临床需求更强的适应性,使其成为提高放疗疗效不可或缺的资产。

英文摘要:

Background and Purpose: Accurate motion tracking in MRI-guided Radiotherapy (MRIgRT) is essential for effective treatment delivery. This study aimed to enhance motion tracking precision in MRIgRT through an automatic real-time markerless tracking method using an enhanced Tracking-Learning-Detection (ETLD) framework with automatic segmentation. Materials and Methods: We developed a novel MRIgRT motion tracking and segmentation method by integrating the ETLD framework with an improved Chan-Vese model (ICV), named ETLD+ICV. The ETLD framework was upgraded for real-time cine MRI, including advanced image preprocessing, no-reference image quality assessment, an enhanced median-flow tracker, and a refined detector with dynamic search region adjustments. ICV was used for precise target volume coverage, refining the segmented region frame by frame using tracking results, with key parameters optimized. The method was tested on 3.5D MRI scans from 10 patients with liver metastases. Results: Evaluation of 106,000 frames across 77 treatment fractions showed sub-millimeter tracking errors of less than 0.8mm, with over 99% precision and 98% recall for all subjects in the Beam Eye View(BEV)/Beam Path View(BPV) orientation. The ETLD+ICV method achieved a dice global score of more than 82% for all subjects, demonstrating the method's extensibility and precise target volume coverage. Conclusion: This study successfully developed an automatic real-time markerless motion tracking method for MRIgRT that significantly outperforms current methods. The novel method not only delivers exceptional precision in tracking and segmentation but also shows enhanced adaptability to clinical demands, making it an indispensable asset in improving the efficacy of radiotherapy treatments.