Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUS
Niek R. F. Huttinga, Tom Bruijnen, Cornelis A. T. van den Berg, Alessandro Sbrizzi
备注:
This manuscript has supplementary files which can be downloaded at https://surfdrive.surf.nl/files/index.php/s/vz2xmwliglRmcjo. The files include six videos that show reconstructed motion-fields and a document with supporting figures. See Appendix I for a description of all individual files
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy with MRI, and adjusting the radiotherapy plan accordingly. Optimal MR-guidance for respiratory motion during radiotherapy requires MR-based 3D motion estimation with a latency of 200-500 ms. Currently this is still challenging since typical methods rely on MR-images, and are therefore limited by the 3D MR-imaging latency. In this work, we present a method to perform non-rigid 3D respiratory motion estimation with 170 ms latency, including both acquisition and reconstruction. The proposed method called real-time low-rank MR-MOTUS reconstructs motion-fields directly from k-space data, and leverages an explicit low-rank decomposition of motion-fields to split the large scale 3D+t motion-field reconstruction problem posed in our previous work into two parts: (I) a medium-scale offline preparation phase and (II) a small-scale online inference phase which exploits the results of the offline phase for real-time computations. The method was validated on free-breathing data of five volunteers, acquired with a 1.5T Elekta Unity MR-Linac. Results show that the reconstructed 3D motion-field are anatomically plausible, highly correlated with a self-navigation motion surrogate (R = 0.975 +/- 0.0110), and can be reconstructed with a total latency of 170 ms that is sufficient for real-time MR-guided abdominal radiotherapy.
With the recent introduction of the MR-LINAC, an MR-scanner combined with a radiotherapy LINAC, MR-based motion estimation has become of increasing interest to (retrospectively) characterize tumor and organs-at-risk motion during radiotherapy. To this extent, we introduce low-rank MR-MOTUS, a framework to retrospectively reconstruct time-resolved non-rigid 3D+t motion-fields from a single low-resolution reference image and prospectively undersampled k-space data acquired during motion. Low-rank MR-MOTUS exploits spatio-temporal correlations in internal body motion with a low-rank motion model,…
Respiratory-gated radiation therapy (RGRT) has been used to minimize the dose to normal tissue in lung-cancer radiotherapy. The present research aims to improve the regularity of respiration in RGRT using a video coached respiration guiding system. In the study, 16 patients with lung cancer were evaluated. The respiration signals of the patients were measured by a real-time position management (RPM) Respiratory Gating System (Varian, USA) and the patients were trained using the video coached respiration guiding system. The patients performed free breathing and guided breathing, and the respira…
During respiratory-gated radiotherapy (RGRT), gate on and off latencies cause deviations of gating windows, possibly leading to delivery of low- and high-dose radiations to tumors and normal tissues, respectively. Currently, there are no RGRT systems that have definite tools to compensate for the delays. To address the problem, we propose a framework consisting of two steps: 1) multi-step-ahead prediction and 2) prediction-based gating. For each step, we have devised a specific algorithm to accomplish the task. Numerical experiments were performed using respiratory signals of a phantom and ten…
Purpose: Respiratory gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung cancer patients. Determinations of the gating window in the respiratory phase of patients are important in RGRT but it is not easy. The objective of this study was to determine the optimal gating window with a visible guiding system in RGRT. Materials and Methods: Between April and October in 2014 the breathing signals of 23 lung cancer patients were recorded with a Real-time Position Management (RPM) respiratory gating system (Varian, USA). We performed statistical analysis with…
Recently we have developed an algorithm for reconstructing volumetric images and extracting 3D tumor motion information from a single x-ray projection. We have demonstrated its feasibility using a digital respiratory phantom with regular breathing patterns. In this work, we present a detailed description and a comprehensive evaluation of the improved algorithm. The algorithm was improved by incorporating respiratory motion prediction. The accuracy and efficiency were then evaluated on 1) a digital respiratory phantom, 2) a physical respiratory phantom, and 3) five lung cancer patients. These e…
Baltic Institute of Advanced Technology(波罗的海高级技术研究所);Vytautas Magnus University(维陶塔斯·马格努斯大学);Aalto University(阿尔托大学);Rubedo Systems, UAB(Rubedo系统有限责任公司);Hospital of Lithuanian University of Health Sciences Kauno Klinikos(立陶宛健康科学大学考纳斯诊所医院)
Purpose. Radiation therapy is a local treatment aimed at cells in and around a tumor. The goal of this study is to develop an algorithmic solution for predicting the position of a target in 3D in real time, aiming for the short fixed calibration time for each patient at the beginning of the procedure. Accurate predictions of lung tumor motion are expected to improve the precision of radiation treatment by controlling the position of a couch or a beam in order to compensate for respiratory motion during radiation treatment. Methods. For developing the algorithmic solution, data mining technique…
Estimation of internal body motion with high spatio-temporal resolution can greatly benefit MR-guided radiotherapy/interventions and cardiac imaging, but remains a challenge to date. In image-based methods, where motion is indirectly estimated by reconstructing and co-registering images, a trade off between spatial and temporal resolution of the motion-fields has to be made due to the image reconstruction step. However, we observe that motion-fields are very compressible due to the spatial correlation of internal body motion. Therefore, reconstructing only motion-fields directly from surrogate…
Intrafraction motion can play a pivotal role in the success of abdominal and thoracic radiation therapy. Hybrid magnetic resonance-guided radiotherapy systems have the potential to control for intrafraction motion. Recently, we introduced an MRI sequence capable of acquiring real-time cine imaging in two orthogonal planes (SOPI). We extend SOPI here to permit dynamic updating of slice positions in one plane while keeping the other plane position fixed. In this implementation, cine images from the static plane are used for motion monitoring and as image navigators to sort stepped images in the …
Modeling of respiratory motion is important for a more accurate understanding and accounting of its effect on dose to cancers in the thorax and abdomen by radiotherapy. We have developed a model of respiration-induced organ motion in the thorax, without the commonly adopted assumption of repeatable breath cycles. The model describes the motion of a volume of interest within the patient, based on a reference 3-dimensional image (at end-expiration), and the diaphragm positions at different time points. The input data are respiration-correlated CT images of patients treated for nonsmall cell lung…
The Role of Free-breathing GRASP MRI in Accurate Phase Matching with 4D-CT for Motion Representation in Liver Cancer Radiotherapy
Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology(华中科技大学同济医学院同济医院);Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College(中国医学科学院北京协和医学院肿瘤医院/国家癌症中心/国家临床医学研究中心放射肿瘤科);School of Electronic Engineering, Beijing University of Posts and Telecommunications(北京邮电大学电子工程学院)
Respiratory motion during radiotherapy causes uncertainty in the tumor's location, which is typically addressed by an increased radiation area and a decreased dose. As a result, the treatments' efficacy is reduced. The recently proposed hybrid MR-linac scanner holds the promise to efficiently deal with such respiratory motion through real-time adaptive MR-guided radiotherapy (MRgRT). For MRgRT, motion-fields should be estimated from MR-data and the radiotherapy plan should be adapted in real-time according to the estimated motion-fields. All of this should be performed with a total latency of …
A new strategy for radiation therapy dosimetry planning (RTDP) used to reduce dose estimation errors due to respiratory motion in breast treatment was illustrated and evaluated in this study. On CT data set acquired for breast treatment, six different RTDP tangential techniques were performed: (i) three-dimensional conformal radiotherapy (3DCRT) with physical wedge, (ii) 3DCRT with virtual wedge, (iii) motion management technique (MMT) with physical wedge, (iv) MMT with virtual wedge, (v) 3DCRT with field-in-field, and (vi) intensity-modulated radiation therapy (IMRT) with direct aperture opti…
Cherenkov Imaged Bio-morphological Features Verify Patient Positioning with Deformable Tissue Translocation in Breast Radiotherapy
Dartmouth College(达特茅斯学院);Dartmouth Cancer Center(达特茅斯癌症中心);Dartmouth Health(达特茅斯健康);University of Wisconsin-Madison(威斯康星大学麦迪逊分校);University of Missouri-Columbia(密苏里大学哥伦比亚分校)
MRI-guided cardiac radiotherapy using a 1.5 T MR-linac: surveying emerging patterns of care
University Medical Center Utrecht(乌得勒支大学医学中心);University of Texas MD Anderson Cancer Center(德克萨斯大学安德森癌症中心);Allegheny Health Network(阿勒格尼健康网络);GenesisCare(创生医疗)