Modeling of respiratory motion is important for a more accurate understanding and accounting of its effect on dose to cancers in the thorax and abdomen by radiotherapy. We have developed a model of respiration-induced organ motion in the thorax, without the commonly adopted assumption of repeatable breath cycles. The model describes the motion of a volume of interest within the patient, based on a reference 3-dimensional image (at end-expiration), and the diaphragm positions at different time points. The input data are respiration-correlated CT images of patients treated for nonsmall cell lung cancer, consisting of 3D images, including the diaphragm positions, at 10 phases of the respiratory cycle. A deformable image registration algorithm calculates the deformation field that maps each 3D image to the reference 3D image. A principle component analysis is performed to parameterize the 3D deformation field in terms of the diaphragm motion. We show that the first two principal components are adequate to accurately and completely describe the organ motion in the data of 4 patients. Artifacts in the RCCT images that commonly occur at the mid-respiration states are reduced in the model-generated images. Further validation of the model is demonstrated in the successful application of the parameterized 3D deformation field to RCCT data of the same patient but acquired several days later. We have developed a method for predicting respiration-induced organ motion in patients that has potential for improving the accuracy of dose calculation in radiotherapy.
Quantification of head and neck cancer patients' anatomical changes during radiotherapy: prediction of replanning need
McGill University(麦吉尔大学);Research Institute of the McGill University Health Centre, McGill University(麦吉尔大学健康中心研究所,麦吉尔大学);Department of Radiation Oncology, Hôpital Maisonneuve-Rosemont(Maisonneuve-Rosemont医院放射肿瘤科);Department of Radiation Oncology, McGill University(麦吉尔大学放射肿瘤科)
Digital Twins of Mechanically Ventilated Preterm Neonates with Respiratory Distress Syndrome
School of Engineering, University of Warwick(华威大学工程学院);Centre for Perinatal Research, School of Medicine, University of Nottingham(诺丁汉大学医学院围产期研究中心);Nottingham Centre for Neonatal Care, Queen’s Medical Centre(诺丁汉新生儿护理中心,女王医疗中心)
Validated respiratory drug deposition predictions from 2D and 3D medical images with statistical shape models and convolutional neural networks
Heriot-Watt University(赫瑞瓦特大学);Royal Hospital for Children and Young People, NHS Lothian(NHS洛锡安区儿童与青少年皇家医院);University Hospital Southampton NHS Foundation Trust(南安普顿大学医院NHS基金会信托);Brunel University(布鲁内尔大学);University of Edinburgh(爱丁堡大学)
CPT-4DMR: Continuous sPatial-Temporal Representation for 4D-MRI Reconstruction
Center for Proton Therapy, Paul Scherrer Institut(质子治疗中心,保罗·施特格勒研究所);Department of Physics, ETH Zurich(苏黎世联邦理工学院物理系);Department of Computer Science, ETH Zurich(苏黎世联邦理工学院计算机科学系);Department of Radiology, Division of Radiological Physics, University Hospital Basel(巴塞尔大学医院放射科,放射物理 division);Department of Biomedical Engineering, University of Basel(巴塞尔大学生物医学工程系);Institute for Biomedical Engineering, University and ETH Zurich(生物医学工程研究所,大学与苏黎世联邦理工学院)
Patient-Specific Deep Reinforcement Learning for Automatic Replanning in Head-and-Neck Cancer Proton Therapy
Department of Radiation and Cellular Oncology University of Chicago(辐射与细胞肿瘤学系,芝加哥大学);Division of Environmental and Occupational Health Sciences University of Illinois at Chicago(环境与职业卫生科学系,伊利诺伊大学芝加哥分校);Department of Radiation Oncology and Winship Cancer Institute Emory University(放射肿瘤学系和Winship癌症研究所,埃默里大学)
Predicting respiratory motion for real-time tumour tracking in radiotherapy
Baltic Institute of Advanced Technology(波罗的海高级技术研究所);Vytautas Magnus University(维陶塔斯·马格努斯大学);Aalto University(阿尔托大学);Rubedo Systems, UAB(Rubedo系统有限责任公司);Hospital of Lithuanian University of Health Sciences Kauno Klinikos(立陶宛健康科学大学考纳斯诊所医院)
Closed-loop coupling of personalised and foundation models for real-time treatment guidance with MRI
Image X Institute, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia(悉尼大学医学与健康学院悉尼健康科学学院Image X研究所,悉尼,澳大利亚);GenesisCare, Sydney, Australia(GenesisCare,悉尼,澳大利亚);School of Clinical Medicine, Medicine & Health, University of New South Wales, Sydney, Australia(新南威尔士大学医学与健康学院临床医学系,悉尼,澳大利亚);Centre for Medical Radiation Physics, School of Mathematics and Physics, University of Wollongong, Wollongong, Australia(伍伦贡大学数学与物理学院医学辐射物理中心,伍伦贡,澳大利亚)